Occupational eye dose in interventional cardiology procedures
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
It is important to measure the radiation dose [3-mm dose equivalent, Hp(3)] in the eye. This study was to determine the current occupational radiation eye dose of staff conducting interventional cardiology procedures, using a novel direct eye dosimeter. We measured the occupational eye dose [Hp(3)] in physicians and nurses in a catheterization laboratory for 6-months. The eye doses [Hp(3)] of 12 physicians (9 with Pb glasses, 3 without), and 11 nurses were recorded using a novel direct eye dosimeter, the DOSIRIS TM. We placed dosimeters above and under the glasses. We also estimated the eye dose [0.07-mm dose equivalent] using a neck personal dosimeter. The eye doses among interventional staff ranked in the following order: physicians without Pb glasses > physicians with Pb glasses > nurses. The shielding effect of the glasses (0.07-mm Pb) in a clinical setting was approximately 60%. In physicians who do not wear Pb glasses, the eye dose may exceed the new regulatory limit for IR staff. We found good correlations between the neck dosimeter dose and eye dosimeter dose (inside or outside glasses, R 2 = 0.93 and R 2 = 0.86, respectively) in physicians. We recommend that interventional physicians use an eye dosimeter for correct evaluation of the lens dose.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
Stewart, F. A., Akleyev, A. V., Hauer-Jensen, M., Hendry, J. H., Kleiman, N. J., MacVittie, T. J., Aleman, B. M., Edgar, A. B., Mabuchi, K., Muirhead, C. R., et al. (2012) · Annals of the ICRP · doi:10.1016/j.icrp.2012.02.001 · Cited by 1,604
Valentin, J. (2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00004-5 · Cited by 964
ICRP Publication 120: Radiological Protection in Cardiology
Cousins, C., Miller, D. L., Bernardi, G., Rehani, M. M., Schofield, P., Vañó, E., Einstein, A. J., Geiger, B., Heintz, P., Padovani, R., et al. (2013) · Annals of the ICRP · doi:10.1016/j.icrp.2012.09.001 · Cited by 428
Patient Skin Reactions From Interventional Fluoroscopy Procedures
Balter, S., & Miller, D. L. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.12029 · Cited by 122
Koukorava, C., Farah, J., Struelens, L., Clairand, I., Donadille, L., Vanhavere, F., & Dimitriou, P. (2014) · Journal of Radiological Protection · doi:10.1088/0952-4746/34/3/509 · Cited by 105
Martin, C. J., & Magee, J. S. (2013) · Journal of Radiological Protection · doi:10.1088/0952-4746/33/2/445 · Cited by 81
JCS Joint Working Group (2013) · Circulation Journal · doi:10.1253/circj.cj-66-0065 · Cited by 66
FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS
Clairand, I., Ginjaume, M., Vanhavere, F., Carinou, E., Daures, J., Denozière, M., da Silva, E. H., Roig, M., Principi, S., & Rycheghem, L. V. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv368 · Cited by 36
Metadata
- Authors
- Haga, Y., Chida, K., Kaga, Y., Sota, M., Meguro, T., & Zuguchi, M.
- Venue
- Scientific Reports
- Published
- 2017-04-03
- Volume
- 7
- Issue
- 1
- Pages
- 569-569
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2600748278
- Cited by
- 189
- References
- 10
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Occupational eye dose in interventional cardiology procedures. https://app.cochat.ai/papers/10.1038/s41598-017-00556-3
- The paper
- Haga, Y., Chida, K., Kaga, Y., Sota, M., Meguro, T., & Zuguchi, M. (2017). Occupational eye dose in interventional cardiology procedures. Scientific Reports. https://doi.org/10.1038/s41598-017-00556-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.