CoChat

A comparison of methods to measure central and peripheral oxytocin concentrations in human and non-human primates

Open access
Lefevre, Arthur, Mottolese, Raphaëlle, Dirheimer, Manon, Mottolese, Carmine, Duhamel, Jean-René, Sirigu, Angela · 2017 · Scientific Reports

The DOI matches its Crossref record; 54 of the 55 references it cites were found in a registry or an index.

Abstract

Oxytocin (OT) concentration in the blood is considered to be a marker of its action in the brain. However, two problems have emerged when measuring OT level in the blood. First, it is unclear whether different methods of assessment lead to similar OT values. Second, it is unclear if plasma OT concentrations is informative on what OT does in the brain. To clarify these issues, we collected cerebrospinal fluid (CSF) from the brain ventricle of 25 patients during surgery to compare with plasma OT after simultaneous blood withdrawal. Additionally, we collected 12 CSF and blood samples from non-human primates while awake or under anaesthesia. We used four methods to assay OT concentrations: Commercial EIA with/without extraction, laboratory developed EIA with filtration and RIA with extraction. Three of these methods showed a positive correlation between plasma and CSF OT, suggesting a link between plasma and central OT, at least under specific testing conditions. However, none of the methods correlated to each other. Our results show major disagreements among methods used here to measure peripheral and brain OT and therefore they call for more caution when plasma OT is taken as a marker of central OT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-017-17674-7

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Correlation between OT concentration in the CSF (OTc, horizontal axis) and in the plasma (OTp, vertical axis). Data are log-transformed. R = Pearson’s correlation coefficient and p = p-values.
Figure 1 Correlation between OT concentration in the CSF (OTc, horizontal axis) and in the plasma (OTp, vertical axis). Data are log-transformed. R = Pearson’s correlation coefficient and p = p-values.CC BY · PubMed Central
Figure 2 Between methods correlation of OT concentrations in the CSF. Data are log-transformed. R = Pearson’s correlation coefficient and p = p-values.
Figure 2 Between methods correlation of OT concentrations in the CSF. Data are log-transformed. R = Pearson’s correlation coefficient and p = p-values.CC BY · PubMed Central
Figure 3 Between methods correlations of OT concentrations in the plasma. Data are log-transformed. R = Pearson’s correlation coefficient and p = p-values.
Figure 3 Between methods correlations of OT concentrations in the plasma. Data are log-transformed. R = Pearson’s correlation coefficient and p = p-values.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 54 references

Cited by

See all 105

Metadata

Authors
Lefevre, A., Mottolese, R., Dirheimer, M., Mottolese, C., Duhamel, J.-R., & Sirigu, A.
Affiliations
  • Lyon 1 Université (FR)
  • Centre National de la Recherche Scientifique (FR)
Venue
Scientific Reports
Published
2017-12-08
Volume
7
Issue
1
Pages
17222-17222
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2771444275
Cited by
105
References
55
Citations by year
2026: 6 · 2025: 7 · 2024: 14 · 2023: 8 · 2022: 17 · 2021: 26 · 2020: 7 · 2019: 5 · 2018: 15
FWCI
10.57
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • Agence Nationale de la Recherche (ANR-11-LABEX-0042, 11-LABEX-0042, ANR-11-LABX-0042)
  • Centre National de la Recherche Scientifique
  • Université de Lyon (ANR-11-LABEX-0042)
Topics
  • Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroendocrine regulation and behavior
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuropeptides and Animal Physiology
  • Life Sciences › Neuroscience › Behavioral Neuroscience › Stress Responses and Cortisol
Keywords
oxytocin, plasma oxytocin, cerebrospinal fluid, immunoassay comparison, radioimmunoassay, enzyme immunoassay, non-human primates, patients, anesthesia, biomarker validity
MeSH terms
Adult, Aged, Aged, 80 and over, Animals, Blood Chemical Analysis, Female, Humans, Macaca mulatta, Male, Middle Aged, Oxytocin, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of methods to measure central and peripheral oxytocin concentrations in human and non-human primates. https://app.cochat.ai/papers/10.1038/s41598-017-17674-7
The paper
Lefevre, A., Mottolese, R., Dirheimer, M., Mottolese, C., Duhamel, J.-R., & Sirigu, A. (2017). A comparison of methods to measure central and peripheral oxytocin concentrations in human and non-human primates. Scientific Reports. https://doi.org/10.1038/s41598-017-17674-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.