CoChat

Mechanical Vibration Influences the Perception of Electrovibration

Open access
Ryu, Semin, Pyo, Dongbum, Lim, Soo-Chul, Kwon, Dong-Soo · 2018 · Scientific Reports

The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.

Abstract

Recently, various methods using, simultaneously, two types of tactile feedback have been proposed to emulate a real object. However, the possible masking effect when providing two types of tactile feedback has been scarcely reported. In this study, we investigated the masking effect caused by mechanical vibration on the perception of electrovibration. The absolute and difference thresholds of the electrovibration were measured according to the presence/absence, frequency, and intensity of the mechanical vibration. The absolute threshold of electrovibration tended to increase in the form of a ramp function, as the intensity of the masking stimulus (mechanical vibration) increased. Particularly, the masking effect was more remarkable when the frequency of both the target and the masking stimulus was the same (up to 13 dB increase with 25 dB SL masker). Furthermore, the difference in the threshold (average of 1.21 dB) did not significantly change due to the masking stimulus, when the sensation level intensity of the target stimulus was within the section following the Weber’s law. The results further indicated that electrovibration contributes to the activation of slowly adapting afferents as well. This investigation will provide important guidelines for the design of haptic interface that employs multiple types of tactile feedback.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-018-22865-x

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Absolute thresholds (AL) of electrovibration (EV) and mechanical vibration (MV). (a) Mean absolute threshold of electrovibration for three test frequencies with standard error bars (filled circle, left axis) and the absolute threshold curve of the tangential force, as obtained by Israr et al.35 (dashed line, right axis). The open-star symbol, which was not used for analysis, denotes the roughly estimated absolute threshold of electrovibration at 400 Hz, as obtained from a pilot test. (b) Mean absolute threshold of mechanical vibration for three test frequencies with standard error bars (filled circle, left axis) and the absolute threshold curve of acceleration, as obtained by Morioka et al.36 (dashed line, right axis).
Figure 1 Absolute thresholds (AL) of electrovibration (EV) and mechanical vibration (MV). (a) Mean absolute threshold of electrovibration for three test frequencies with standard error bars (filled circle, left axis) and the absolute threshold curve of the tangential force, as obtained by Israr et al.35 (dashed line, right axis). The open-star symbol, which was not used for analysis, denotes the roughly estimated absolute threshold of electrovibration at 400 Hz, as obtained from a pilot test. (b) Mean absolute threshold of mechanical vibration for three test frequencies with standard error bars (filled circle, left axis) and the absolute threshold curve of acceleration, as obtained by Morioka et al.36 (dashed line, right axis).CC BY · PubMed Central
Figure 2 Changes in the absolute threshold (AL) and difference threshold (DL) of electrovibration (EV) in the presence of mechanical vibration (MV). (a) Mean changes in the absolute threshold of EV at 270 Hz under masker conditions (120, 180, and 270 Hz with 5–25 dB SL) with standard error bars. To evaluate the masking effects, the unmasked ALs of EV at 270 Hz in Experiment 1 were subtracted from the corresponding masked ALs, which were measured in Experiment 2. Asterisks denote that the data column is significantly different from zero (p < 0.0.05). (b) Mean changes in the difference threshold of EV at 270 Hz under masker conditions (120, 180, and 270 Hz with 10 dB SL and 20 dB SL) with standard error bars. To evaluate the masking effects, the unmasked DLs of EV at 270 Hz were subtracted from the corresponding masked DLs.
Figure 2 Changes in the absolute threshold (AL) and difference threshold (DL) of electrovibration (EV) in the presence of mechanical vibration (MV). (a) Mean changes in the absolute threshold of EV at 270 Hz under masker conditions (120, 180, and 270 Hz with 5–25 dB SL) with standard error bars. To evaluate the masking effects, the unmasked ALs of EV at 270 Hz in Experiment 1 were subtracted from the corresponding masked ALs, which were measured in Experiment 2. Asterisks denote that the data column is significantly different from zero (p < 0.0.05). (b) Mean changes in the difference threshold of EV at 270 Hz under masker conditions (120, 180, and 270 Hz with 10 dB SL and 20 dB SL) with standard error bars. To evaluate the masking effects, the unmasked DLs of EV at 270 Hz were subtracted from the corresponding masked DLs.CC BY · PubMed Central
Figure 3 Hardware setup for generating both electrovibration and mechanical vibration stimuli.
Figure 3 Hardware setup for generating both electrovibration and mechanical vibration stimuli.CC BY · PubMed Central
Figure 4 Stimulus sequence within a three-interval, forced-choice (3IFC) paradigm. (a) Stimulus sequence in Experiment 1. (b) Stimulus sequence in Experiment 2. (c) Stimulus sequence in Experiment 3. (d) Sliding speed and distance in each interval during the experimental run.
Figure 4 Stimulus sequence within a three-interval, forced-choice (3IFC) paradigm. (a) Stimulus sequence in Experiment 1. (b) Stimulus sequence in Experiment 2. (c) Stimulus sequence in Experiment 3. (d) Sliding speed and distance in each interval during the experimental run.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 57 references

Cited by

See all 33

Metadata

Authors
Ryu, S., Pyo, D., Lim, S.-C., & Kwon, D.-S.
Affiliations
  • Hallym University (KR)
  • Electronics and Telecommunications Research Institute (KR)
  • Dongguk University (KR)
  • Korea Advanced Institute of Science and Technology (KR)
Corresponding author
Kwon, Dong-Soo
Venue
Scientific Reports
Published
2018-03-14
Volume
8
Issue
1
Pages
4555-4555
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2793060613
Cited by
31
References
57
Citations by year
2026: 2 · 2025: 4 · 2024: 2 · 2023: 1 · 2022: 5 · 2021: 4 · 2020: 9 · 2019: 4
FWCI
2.53
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • National Research Foundation
  • National Research Foundation of Korea
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
electrovibration, mechanical vibration, masking, tactile perception, absolute threshold, just noticeable difference, haptic feedback, slowly adapting afferents, Weber's law, haptic device design

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical Vibration Influences the Perception of Electrovibration. https://app.cochat.ai/papers/10.1038/s41598-018-22865-x
The paper
Ryu, S., Pyo, D., Lim, S.-C., & Kwon, D.-S. (2018). Mechanical Vibration Influences the Perception of Electrovibration. Scientific Reports. https://doi.org/10.1038/s41598-018-22865-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.