Assessing the elastic properties of skeletal muscle and tendon using shearwave ultrasound elastography and MyotonPRO
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The purposes of this study were to compare Young’s modulus values determined by shear wave ultrasound elastography (SWUE) with stiffness index obtained using a hand-held MyotonPRO device on the resting stiffness of gastrocnemius muscle belly and Achilles tendon; and to examine the test-retest reliability of those stiffness measurement using hand-held MyotonPRO. Twenty healthy volunteers participated in the study. The measurement values of muscle and tendon was determined in dominant legs. Each marker point was assessed using MyotonPRO and SWUE, respectively. Intra-operator reliability of MyotonPRO was established in 10 of the subjects. The correlation coefficients between the values of muscle and tendon stiffness indices determined by MyotonPRO and SWUE were calculated. Significant correlations were found for muscle and tendon stiffness and Young’s modulus ranged from 0.463 to 0.544 (all P < 0.05). The intra-operator reliability ranged from good to excellent (ICC(3,1) = 0.787~0.928). These results suggest that the resting stiffness of gastrocnemius muscle belly and Achilles tendon measured by MyotonPRO is related to the Young’s modulus of those quantified by SWUE. The MyotonPRO shows good intra-operator repeatability. Therefore, the present study shows that MyotonPRO can be used to assess mechanical properties of gastrocnemius muscle belly and Achilles tendon with a resting condition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Foundations of Clinical Research: Applications to Practice,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00362-4 · Cited by 9,489
The mechanics of running: How does stiffness couple with speed?
McMahon, T. A., & Cheng, G. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90042-2 · Cited by 1,121
Bland, J. M., & Altman, D. G. (1990) · Computers in Biology and Medicine · doi:10.1016/0010-4825(90)90013-f · Cited by 691
Validation of shear wave elastography in skeletal muscle
Eby, S. F., Song, P., Chen, S., Chen, Q., Greenleaf, J. F., & An, K.-N. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.07.033 · Cited by 545
Physical Therapy Research: Principles and Applications
Domholdt, E. (1993) · Medical Entomology and Zoology · Cited by 441
Kot, B. C. W., Zhang, Z. J., Lee, A. W. C., Leung, V. Y. F., & Fu, S. N. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044348 · Cited by 320
Self-citationEby, S. F., Cloud, B. A., Brandenburg, J. E., Giambini, H., Song, P., Chen, S., LeBrasseur, N. K., & An, K.-N. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2014.11.011 · Cited by 295
Maïsetti, O., Hug, F., Bouillard, K., & Nordez, A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.009 · Cited by 263
Nordez, A., & Hug, F. (2010) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01323.2009 · Cited by 251
Supersonic shear imaging provides a reliable measurement of resting muscle shear elastic modulus
Lacourpaille, L., Hug, F., Bouillard, K., Hogrel, J.-Y., & Nordez, A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/n19 · Cited by 237
Drakonaki, E. E., Allen, G. M., & Wilson, D. J. (2009) · Clinical Radiology · doi:10.1016/j.crad.2009.08.006 · Cited by 230
Aird, L., Samuel, D., & Stokes, M. (2012) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2012.03.005 · Cited by 218
Acute Effect of Static Stretching on Hardness of the Gastrocnemius Muscle
AKAGI, R., & TAKAHASHI, H. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182850e17 · Cited by 148
Andonian, P., Viallon, M., Goff, C. M. L., de Bourguignon, C., Tourel, C., Morel, J., Giardini, G., Gergelé, L., Millet, G. P., & Croisille, P. (2016) · PLoS ONE · doi:10.1371/journal.pone.0161855 · Cited by 134
Yanagisawa, O., Niitsu, M., Kurihara, T., & Fukubayashi, T. (2011) · Clinical Radiology · doi:10.1016/j.crad.2011.03.012 · Cited by 130
Elastography: modality-specific approaches, clinical applications, and research horizons
Li, Y., & Snedeker, J. G. (2010) · Skeletal Radiology · doi:10.1007/s00256-010-0918-0 · Cited by 130
Self-citationEffect of a 5‐week static stretching program on hardness of the gastrocnemius muscle
Akagi, R., & Takahashi, H. (2014) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12111 · Cited by 125
Nakamura, M., Ikezoe, T., Kobayashi, T., Umegaki, H., Takeno, Y., Nishishita, S., & Ichihashi, N. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.03.024 · Cited by 124
Kuo, W.-H., Jian, D.-W., Wang, T., & Wang, Y. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.11.015 · Cited by 106
Acute decrease in the stiffness of resting muscle belly due to static stretching
Taniguchi, K., Shinohara, M., Nozaki, S., & Katayose, M. (2013) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.12146 · Cited by 104
Fröhlich-Zwahlen, A. K., Casartelli, N. C., Item‐Glatthorn, J. F., & Maffiuletti, N. A. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2014.06.007 · Cited by 93
Kalkhoven, J. T., & Watsford, M. L. (2017) · Journal of Sports Sciences · doi:10.1080/02640414.2017.1349921 · Cited by 90
Cross-Sectional Areas of Fat and Muscle in Limbs During Growth and Middle Age
Kanehisa, H., Ikegawa, S., Tsunoda, N., & Fukunaga, T. (1994) · International Journal of Sports Medicine · doi:10.1055/s-2007-1021081 · Cited by 86
Zhang, Z. J., & Fu, S. N. (2013) · PLoS ONE · doi:10.1371/journal.pone.0068216 · Cited by 82
Self-citationBrandenburg, J. E., Eby, S. F., Song, P., Zhao, H., Landry, B. W., Kingsley‐Berg, S. M., Bamlet, W. R., Chen, S., Sieck, G. C., & An, K. (2015) · Journal of Ultrasound in Medicine · doi:10.7863/ultra.34.4.663 · Cited by 80
Feasibility assessment of shear wave elastography to rotator cuff muscle
Itoigawa, Y., Sperling, J. W., Steinmann, S. P., Chen, Q., Song, P., Chen, S., Itoi, E., Hatta, T., & An, K. (2014) · Clinical Anatomy · doi:10.1002/ca.22498 · Cited by 79
ShearWave elastography: repeatability for measurement of tendon stiffness
Peltz, C. D., Haladik, J. A., Divine, G., Siegal, D. S., van Holsbeeck, M., & Bey, M. J. (2013) · Skeletal Radiology · doi:10.1007/s00256-013-1629-0 · Cited by 78
Zhang, Z. J., Ng, G. Y.-F., Lee, W. C., & Fu, S. N. (2014) · PLoS ONE · doi:10.1371/journal.pone.0108337 · Cited by 70
Self-citationChiu, T.-C. R., Ngo, H.-C., Lau, L.-W., Leung, K.-W., Lo, M.-H., Yu, H.-F., & Ying, M. T. C. (2016) · PLoS ONE · doi:10.1371/journal.pone.0154443 · Cited by 50
Zhang, Z. J., Ng, G. Y. F., & Fu, S. N. (2015) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3209-6 · Cited by 46
Self-citationPsychometric Properties of the MyotonPRO in Dementia Patients with Paratonia
Drenth, H., Zuidema, S. U., Krijnen, W. P., Bautmans, I., van der Schans, C. P., & Hobbelen, H. J. S. M. (2017) · Gerontology · doi:10.1159/000485462 · Cited by 29
A Novel Sonographic Method of Measuring Patellar Tendon Length
Gellhorn, A. C., Morgenroth, D. C., & Goldstein, B. (2012) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.01.020 · Cited by 26
Determination of blood volume by pulse CO-oximetry
Lalande, S., Kelsey, J. W., Joyner, M. J., & Johnson, B. D. (2011) · Physiological Measurement · doi:10.1088/0967-3334/33/1/19 · Cited by 25
Acute effects of static stretching on leg-spring behavior during hopping
Hobara, H., Inoue, K., Kato, E., & Kanosue, K. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1841-3 · Cited by 19
Borges, P. R. T., Santos, T. R. T., Procópio, P. R. S., Chelidonopoulos, J. H. D., Zambelli, R., & Ocarino, J. M. (2017) · Brazilian Journal of Physical Therapy · doi:10.1016/j.bjpt.2016.12.004 · Cited by 17
Analysis of the correlation between knee extension torque and patellar tendon elastic property
Mannarino, P., Lima, K. M. M. E., Fontenelle, C. R. D. C., da Matta, T. T., de Salles, B. F., Junior, R. F. S., & de Oliveira, L. F. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12424 · Cited by 16
Metadata
- Authors
- Feng, Y. N., Li, Y. P., Liu, C. L., & Zhang, Z. J.
- Venue
- Scientific Reports
- Published
- 2018-11-20
- Volume
- 8
- Issue
- 1
- Pages
- 17064-17064
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2900599202
- Cited by
- 231
- References
- 38
- FWCI
- 11.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.