Reduced False Positives and Improved Reporting of Loop-Mediated Isothermal Amplification using Quenched Fluorescent Primers
Open accessThe DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Loop-mediated isothermal amplification (LAMP) is increasingly used in molecular diagnostics as an alternative to PCR based methods. There are numerous reported techniques to detect the LAMP amplification including turbidity, bioluminescence and intercalating fluorescent dyes. In this report we show that quenched fluorescent labels on various LAMP primers can be used to quantify and detect target DNA molecules down to single copy numbers. By selecting different fluorophores, this method can be simply multiplexed. Moreover this highly specific LAMP detection technique can reduce the incidence of false positives originating from mispriming events. Attribution of these events to particular primers will help inform and improve LAMP primer design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Holland, P. M., Abramson, R. D., Watson, R., & Gelfand, D. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.16.7276 · Cited by 2,693
Accelerated reaction by loop-mediated isothermal amplification using loop primers
Nagamine, K., Hase, T., & Notomi, T. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2002.0415 · Cited by 2,045
Tomita, N., Mori, Y., Kanda, H., & Notomi, T. (2008) · Nature Protocols · doi:10.1038/nprot.2008.57 · Cited by 1,867
Vogelstein, B., & Kinzler, K. W. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.16.9236 · Cited by 1,770
Mori, Y., Nagamine, K., Tomita, N., & Notomi, T. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5921 · Cited by 1,711
The real-time polymerase chain reaction
Kubista, M., Andrade, J. M., Bengtsson, M., Forootan, A., Jonák, J., Lind, K., Sindelka, R., Sjöback, R., Sjögreen, B., Strömbom, L., et al. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.007 · Cited by 1,515
Goto, M., Honda, E., Ogura, A., Nomoto, A., & Hanaki, K.-I. (2009) · BioTechniques · doi:10.2144/000113072 · Cited by 1,063
Gleave, A. P. (1992) · Plant Molecular Biology · doi:10.1007/bf00028910 · Cited by 1,006
Visual Detection of Isothermal Nucleic Acid Amplification Using pH-Sensitive Dyes
Tanner, N. A., Zhang, Y., & Evans, T. C. (2015) · BioTechniques · doi:10.2144/000114253 · Cited by 718
Tolerance of loop-mediated isothermal amplification to a culture medium and biological substances
Kaneko, H., Kawana, T., Fukushima, E., & Suzutani, T. (2007) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2006.08.008 · Cited by 707
Real-time turbidimetry of LAMP reaction for quantifying template DNA
Mori, Y., Kitao, M., Tomita, N., & Notomi, T. (2004) · Journal of Biochemical and Biophysical Methods · doi:10.1016/j.jbbm.2003.12.005 · Cited by 627
Iwamoto, T., Sonobe, T., & Hayashi, K. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.6.2616-2622.2003 · Cited by 612
Nucleic Acid Isothermal Amplification Technologies—A Review
Gill, P., & Ghaemi, A. (2008) · Nucleosides, Nucleotides and Nucleic Acids · doi:10.1080/15257770701845204 · Cited by 534
Poon, L. L., Wong, B. W., Ma, E. H., Chan, K. H., Chow, L. M., Abeyewickreme, W., Tangpukdee, N., Yuen, K. Y., Guan, Y., Looareesuwan, S., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.057901 · Cited by 476
Miniaturized isothermal nucleic acid amplification, a review
Asiello, P. J., & Baeumner, A. J. (2011) · Lab on a Chip · doi:10.1039/c0lc00666a · Cited by 445
Torimura, M., Kurata, S., Yamada, K., Yokomaku, T., Kamagata, Y., Kanagawa, T., & Kurane, R. (2001) · Analytical Sciences · doi:10.2116/analsci.17.155 · Cited by 354
Simultaneous Multiple Target Detection in Real-Time Loop-Mediated Isothermal Amplification
Tanner, N. A., Zhang, Y., & Evans, T. C. (2012) · BioTechniques · doi:10.2144/0000113902 · Cited by 280
Njiru, Z. K., Mikosza, A. S. J., Armstrong, T., Enyaru, J. C., Ndung'u, J. M., & Thompson, A. R. C. (2008) · PLoS Neglected Tropical Diseases · doi:10.1371/journal.pntd.0000147 · Cited by 268
Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP)
Curtis, K. A., Rudolph, D. L., & Owen, S. M. (2008) · Journal of Virological Methods · doi:10.1016/j.jviromet.2008.04.011 · Cited by 248
Fischbach, J., Xander, N. C., Frohme, M., & Glökler, J. (2015) · BioTechniques · doi:10.2144/000114275 · Cited by 222
Gadkar, V. J., Goldfarb, D. A., Gantt, S. M., & Tilley, P. A. G. (2018) · Scientific Reports · doi:10.1038/s41598-018-23930-1 · Cited by 214
Sequence specific visual detection of LAMP reactions by addition of cationic polymers
Mori, Y., Hirano, T., & Notomi, T. (2006) · BMC Biotechnology · doi:10.1186/1472-6750-6-3 · Cited by 212
Digital LAMP in a sample self-digitization (SD) chip
Gansen, A., Herrick, A. M., Dimov, I. K., Lee, L. P., & Chiu, D. T. (2012) · Lab on a Chip · doi:10.1039/c2lc21247a · Cited by 187
Ball, C. S., Light, Y. K., Koh, C.-Y., Wheeler, S. S., Coffey, L. L., & Meagher, R. J. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04054 · Cited by 168
Ohtsuka, K., Yanagawa, K., Takatori, K., & Hara‐Kudo, Y. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.11.6730-6735.2005 · Cited by 163
Jiang, Y. S., Bhadra, S., Li, B., Wu, Y. R., Milligan, J. N., & Ellington, A. D. (2015) · Analytical Chemistry · doi:10.1021/ac504387c · Cited by 162
Kiddle, G. A., Hardinge, P., Buttigieg, N., Gandelman, O. A., Pereira, C., McElgunn, C. J., Rizzoli, M., Jackson, R., Appleton, N., Moore, C. A., et al. (2012) · BMC Biotechnology · doi:10.1186/1472-6750-12-15 · Cited by 149
Self-citationLiu, W., Huang, S., Liu, N., Dong, D., Yang, Z., Tang, Y. Y., Ma, W., He, X., Ao, D., Xu, Y., et al. (2017) · Scientific Reports · doi:10.1038/srep40125 · Cited by 142
Lee, D., Mura, M. L., Allnutt, T. R., & Powell, W. (2009) · BMC Biotechnology · doi:10.1186/1472-6750-9-7 · Cited by 126
Chou, P.-H., Lin, Y.-C., Teng, P., Chen, C.-L., & Lee, P.-Y. (2011) · Journal of Virological Methods · doi:10.1016/j.jviromet.2011.01.009 · Cited by 91
Torres, C., Vitalis, E. A., Baker, B. R., Gardner, S. N., Torres, M. W., & Dzenitis, J. M. (2011) · BMC Bioinformatics · doi:10.1186/1471-2105-12-240 · Cited by 91
Point of Care Technologies for HIV
Setty, M. K. H. G., & HEWLETT, I. K. (2014) · AIDS Research and Treatment · doi:10.1155/2014/497046 · Cited by 86
Rapid and real-time detection technologies for emerging viruses of biomedical importance
Parida, M. (2008) · Journal of Biosciences · doi:10.1007/s12038-008-0079-7 · Cited by 86
Loop-Mediated Amplification Accelerated by Stem Primers
Gandelman, O. A., Jackson, R., Kiddle, G. A., & Tisi, L. C. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12129108 · Cited by 85
Improved Performance of Loop-Mediated Isothermal Amplification Assays via Swarm Priming
Martineau, R. L., Murray, S. A., Ci, S., Gao, W., Chao, S.-H., & Meldrum, D. R. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b02578 · Cited by 55
Selection of fluorescent DNA dyes for real-time LAMP with portable and simple optics
Seyrig, G., Stedtfeld, R. D., Tourlousse, D. M., Ahmad, F. J., Towery, K., Cupples, A. M., Tiedje, J. M., & Hashsham, S. A. (2015) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2015.11.004 · Cited by 54
Hardinge, P., Kiddle, G. A., Tisi, L. C., & Murray, J. A. H. (2018) · Scientific Reports · doi:10.1038/s41598-018-36207-4 · Cited by 44
Self-citationStratakos, A. C., Linton, M., Millington, S., & Grant, I. R. (2016) · Journal of Applied Microbiology · doi:10.1111/jam.13381 · Cited by 29
Kubota, R., LaBarre, P., Weigl, B. H., Li, Y. H., Haydock, P. V., & Jenkins, D. M. (2013) · Chinese Science Bulletin · doi:10.1007/s11434-012-5634-9 · Cited by 25
Electric LAMP: Virtual Loop-Mediated Isothermal AMPlification
Salinas, N. R., & Little, D. P. (2012) · ISRN Bioinformatics · doi:10.5402/2012/696758 · Cited by 24
Spinelli, O., Rambaldi, A., Rigo, F., Zanghì, P., D’Agostini, E., Amicarelli, G., Colotta, F., Divona, M., Ciardi, C., Lo‐Coco, F., et al. (2014) · Oncoscience · doi:10.18632/oncoscience.114 · Cited by 21
Cited by
Lu, S., Tong, X., Han, Y., Zhang, K., Zhang, Y., Chen, Q., Duan, J., Lei, X., Huang, M., Qiu, Y., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00861-x · Cited by 395
LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community
Moehling, T. J., Choi, G., Dugan, L. C., Salit, M., & Meagher, R. J. (2021) · Expert Review of Molecular Diagnostics · doi:10.1080/14737159.2021.1873769 · Cited by 286
Augustine, R., Hasan, A., Das, S., Ahmed, R., Mori, Y., Notomi, T., Kevadiya, B., & Thakor, A. (2020) · Biology · doi:10.3390/biology9080182 · Cited by 253
(2023) · doi:10.1016/j.xcrm.2023.101037 · Cited by 75
Metadata
- Authors
- Hardinge, P., & Murray, J. A. H.
- Venue
- Scientific Reports
- Published
- 2019-05-14
- Volume
- 9
- Issue
- 1
- Pages
- 7400-7400
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2944194243
- Cited by
- 179
- References
- 44
- FWCI
- 7.55
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.