The DOI matches its Crossref record.
Loop-Mediated Isothermal Amplification for Direct Detection of Mycobacterium tuberculosis Complex, M. avium , and M. intracellulare in Sputum Samples
Open accessAbstract
Loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method in which reagents react under isothermal conditions with high specificity, efficiency, and rapidity. We used LAMP for detection of Mycobacterium tuberculosis complex, Mycobacterium avium , and Mycobacterium intracellulare directly from sputum specimens as well as for detection of culture isolates grown in a liquid medium (MGIT; Nippon Becton Dickinson Co., Ltd., Tokyo, Japan) or on a solid medium (Ogawa's medium). Species-specific primers were designed by targeting the gyrB gene, and their specificities were validated on 24 mycobacterial species and 7 nonmycobacterial species. The whole procedure is quite simple, starting with the mixing of all reagents in a single tube, followed by an isothermal reaction during which the reaction mixture is held at 63°C. The resulting amplicons are visualized by adding SYBR Green I to the reaction tube. The only equipment needed for the amplification reaction is a regular laboratory water bath or heat block that furnishes a constant temperature of 63°C. The assay had a detection limit of 5 to 50 copies of purified DNA with a 60-min incubation time. The reaction time could be shortened to 35 min for the species identification of M. tuberculosis complex, M. avium , and M. intracellulare from a solid-medium culture. Residual DNA lysates prepared for the Amplicor assay (Roche Diagnostics GmbH) from 66 sputum specimens were tested in the LAMP assay. Although the sample size used for the latter assay was small, 2.75 μl of the DNA lysates, it showed a performance comparable with that of the Amplicor assay, which required 50 μl of the lysates. This LAMP-based assay is simple, rapid, and sensitive; a result is available in 35 min for a solid-medium culture and in 60 min for a liquid-medium culture or for a sputum specimen that contains a corresponding amount of DNA available for testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mori, Y., & Notomi, T. (2009) · Journal of Infection and Chemotherapy · doi:10.1007/s10156-009-0669-9 · Cited by 1,015
Becherer, L., Borst, N., Bakheit, M., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 429
Current and Developing Technologies for Monitoring Agents of Bioterrorism and Biowarfare
Lim, D. V., Simpson, J. M., Kearns, E. A., & Kramer, M. F. (2005) · Clinical Microbiology Reviews · doi:10.1128/cmr.18.4.583-607.2005 · Cited by 417
Facing the Crisis: Improving the Diagnosis of Tuberculosis in the HIV Era
Perkins, M. D., & Cunningham, J. (2007) · The Journal of Infectious Diseases · doi:10.1086/518656 · Cited by 300
Jiang, Y. (., Li, B., Milligan, J. N., Bhadra, S., & Ellington, A. D. (2013) · Journal of the American Chemical Society · doi:10.1021/ja4023978 · Cited by 292
Metadata
- Authors
- Iwamoto, T., Sonobe, T., & Hayashi, K.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2003-06
- Volume
- 41
- Issue
- 6
- Pages
- 2616-2622
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1984966664
- Cited by
- 612
- References
- 0
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Loop-Mediated Isothermal Amplification for Direct Detection of Mycobacterium tuberculosis Complex, M. avium , and M. intracellulare in Sputum Samples. https://app.cochat.ai/papers/10.1128/jcm.41.6.2616-2622.2003
- The paper
- Iwamoto, T., Sonobe, T., & Hayashi, K. (2003). Loop-Mediated Isothermal Amplification for Direct Detection of Mycobacterium tuberculosis Complex, M. avium , and M. intracellulare in Sputum Samples. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.41.6.2616-2622.2003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.