A novel poly (vinyl alcohol)/poly (ethylene glycol) scaffold for tissue engineering with a unique bimodal open-celled structure fabricated using supercritical fluid foaming
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this study, a novel poly (vinyl alcohol) (PVA)/poly (ethylene glycol) (PEG) scaffold was carefully designed via thermal processing and subsequent supercritical fluid (SCF) foaming. Interestingly, a bimodal open-celled structure with interconnected networks was successfully created in the plasticized PVA (WPVA)/PEG scaffold. Large cells were produced from the nucleation sites generated in the PVA phase during rapid depressurization, while plenty of small pores generate in the cell walls of the big cells. The formation mechanism of this cellular structure was studied by considering the various phase morphologies and the diffusion behaviour of the carbon dioxide (CO 2) in individual phases. In addition, the intermolecular interactions of the WPVA/PEG blend were studied using X-ray diffraction and FTIR analysis. The results demonstrate that various types of hydrogen bonds among the hydroxyl groups on the PVA chains, PEG and water molecules are formed in the blend system. The realization of thermoplastic foaming of the PVA/PEG blend benefits from the interactions of complexation and plasticization between water and PEG molecules. The SEM images also revealed that L929 fibroblast cells were able to attach and spread on surfaces of the WPVA/PEG samples. Thus the WPVA/PEG scaffold with unique bimodal cellular structure is nontoxic and favours the attachment and proliferation of cells, making it promising for use as the candidate for tissue engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design of an artificial skin. Part III. Control of pore structure
Dagalakis, N., Flink, J., Stasikelis, P., Burke, J. F., & Yannas, I. V. (1980) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820140417 · Cited by 358
Macrophage Polarization in Response to Varying Pore Sizes of 3D Polyurethane Scaffolds
Liang, R., Fang, D., Lin, W., Wang, Y., Liu, Z., Wang, Y., Zeng, Y., He, M., Li, J., Luo, F., et al. (2018) · Journal of Biomedical Nanotechnology · doi:10.1166/jbn.2018.2629 · Cited by 16
Cited by
Scaffolds for Wound Healing Applications
Negut, I., Dorcioman, G., & Grumezescu, V. (2020) · Polymers · doi:10.3390/polym12092010 · Cited by 415
Supercritical processing of PCL and PCL-PEG blends to produce improved PCL-based porous scaffolds
Guastaferro, M., Baldino, L., Cardea, S., & Reverchon, E. (2022) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2022.105611 · Cited by 30
Metadata
- Authors
- Liu, P., Chen, W., Liu, C., Tian, M., & Liu, P.
- Venue
- Scientific Reports
- Published
- 2019-07-02
- Volume
- 9
- Issue
- 1
- Pages
- 9534-9534
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2953891087
- Cited by
- 167
- References
- 2
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel poly (vinyl alcohol)/poly (ethylene glycol) scaffold for tissue engineering with a unique bimodal open-celled structure fabricated using supercritical fluid foaming. https://app.cochat.ai/papers/10.1038/s41598-019-46061-7
- The paper
- Liu, P., Chen, W., Liu, C., Tian, M., & Liu, P. (2019). A novel poly (vinyl alcohol)/poly (ethylene glycol) scaffold for tissue engineering with a unique bimodal open-celled structure fabricated using supercritical fluid foaming. Scientific Reports. https://doi.org/10.1038/s41598-019-46061-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.