CoChat

Comparability of accelerometer signal aggregation metrics across placements and dominant wrist cut points for the assessment of physical activity in adults

Open access
Migueles, Jairo H., Cadenas-Sanchez, Cristina, Rowlands, Alex V., Henriksson, Pontus, Shiroma, Eric J., Acosta, Francisco M., Rodriguez-Ayllon, Maria, Esteban-Cornejo, Irene, Plaza-Florido, Abel, Gil-Cosano, Jose J., Ekelund, Ulf, van Hees, Vincent T., Ortega, Francisco B. · 2019 · Scientific Reports
Cited by 77

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Large epidemiological studies that use accelerometers for physical behavior and sleep assessment differ in the location of the accelerometer attachment and the signal aggregation metric chosen. This study aimed to assess the comparability of acceleration metrics between commonly-used body-attachment locations for 24 hours, waking and sleeping hours, and to test comparability of PA cut points between dominant and non-dominant wrist. Forty-five young adults (23 women, 18–41 years) were included and GT3X + accelerometers (ActiGraph, Pensacola, FL, USA) were placed on their right hip, dominant, and non-dominant wrist for 7 days. We derived Euclidean Norm Minus One g (ENMO), Low-pass filtered ENMO (LFENMO), Mean Amplitude Deviation (MAD) and ActiGraph activity counts over 5-second epochs from the raw accelerations. Metric values were compared using a correlation analysis, and by plotting the differences by time of the day. Cut points for the dominant wrist were derived using Lin’s concordance correlation coefficient optimization in a grid of possible thresholds, using the non-dominant wrist estimates as reference. They were cross-validated in a separate sample (N = 36, 10 women, 22–30 years). Shared variances between pairs of acceleration metrics varied across sites and metric pairs (range in r 2: 0.19–0.97, all p < 0.01), suggesting that some sites and metrics are associated, and others are not. We observed higher metric values in dominant vs. non-dominant wrist, thus, we developed cut points for dominant wrist based on ENMO to classify sedentary time (<50 m g), light PA (50–110 m g), moderate PA (110–440 m g) and vigorous PA (≥440 m g). Our findings suggest differences between dominant and non-dominant wrist, and we proposed new cut points to attenuate these differences. ENMO and LFENMO were the most similar metrics, and they showed good comparability with MAD. However, counts were not comparable with ENMO, LFENMO and MAD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-019-54267-y

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 77

Metadata

Authors
Migueles, J. H., Cadenas-Sanchez, C., Rowlands, A. V., Henriksson, P., Shiroma, E. J., Acosta, F. M., Rodriguez-Ayllon, M., Esteban-Cornejo, I., Plaza-Florido, A., Gil-Cosano, J. J., Ekelund, U., van Hees, V. T., & Ortega, F. B.
Venue
Scientific Reports
Published
2019-12-03
Volume
9
Issue
1
Pages
18235-18235
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2993825645
Cited by
77
References
13
FWCI
4.86
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparability of accelerometer signal aggregation metrics across placements and dominant wrist cut points for the assessment of physical activity in adults. https://app.cochat.ai/papers/10.1038/s41598-019-54267-y
The paper
Migueles, J. H., Cadenas-Sanchez, C., Rowlands, A. V., Henriksson, P., Shiroma, E. J., Acosta, F. M., Rodriguez-Ayllon, M., Esteban-Cornejo, I., Plaza-Florido, A., Gil-Cosano, J. J., Ekelund, U., van Hees, V. T., & Ortega, F. B. (2019). Comparability of accelerometer signal aggregation metrics across placements and dominant wrist cut points for the assessment of physical activity in adults. Scientific Reports. https://doi.org/10.1038/s41598-019-54267-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.