Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 41 of the 42 references it cites were found in a registry or an index.

Equivalency of four research-grade movement sensors to assess movement behaviors and its implications for population surveillance

Open access
Migueles, Jairo H., Molina-Garcia, Pablo, Torres-Lopez, Lucia V., Cadenas-Sanchez, Cristina, Rowlands, Alex V., Ebner-Priemer, Ulrich W., Koch, Elena D., Reif, Andreas, Ortega, Francisco B. · 2022 · Scientific Reports

Abstract

the benefits of physical activity (PA) and sleep for health, accurate and objective population-based surveillance is important. Monitor-based surveillance has potential, but the main challenge is the need for replicable outcomes from different monitors. This study investigated the agreement of movement behavior outcomes assessed with four research-grade activity monitors (i.e., Movisens Move4, ActiGraph GT3X+, GENEActiv, and Axivity AX3) in adults. Twenty-three participants wore four monitors on the non-dominant wrist simultaneously for seven days. Open-source software (GGIR) was used to estimate the daily time in sedentary, light, moderate-to-vigorous PA (MVPA), and sleep (movement behaviors). The prevalence of participants meeting the PA and sleep recommendations were calculated from each monitor’s data. Outcomes were deemed equivalent between monitors if the absolute standardized difference and its 95% confidence intervals (CI 95%) fell within ± 0.2 standard deviations (SD) of the mean of the differences. The participants were mostly men (n = 14, 61%) and aged 36 (SD = 14) years. Pairwise confusion matrices showed that 83–87% of the daily time was equally classified into the movement categories by the different pairs of monitors. The between-monitor difference in MVPA ranged from 1 (CI 95%: − 6, 7) to 8 (CI 95%: 1, 15) min/day. Most of the PA and sleep metrics could be considered equivalent. The prevalence of participants meeting the PA and the sleep guidelines was 100% consistent across monitors (22 and 5 participants out of the 23, respectively). Our findings indicate that the various research-grade activity monitors investigated show high inter-instrument reliability with respect to sedentary, PA and sleep-related estimates when their raw data are processed in an identical manner. These findings may have important implications for advancement towards monitor-based PA and sleep surveillance systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-022-09469-2

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Pairwise confusion matrices for the sleep, sedentary time, light PA and MVPA expressed in min/day as determined by the different monitors. MVPA moderate-to-vigorous physical activity, PA physical activity.
Figure 1 Pairwise confusion matrices for the sleep, sedentary time, light PA and MVPA expressed in min/day as determined by the different monitors. MVPA moderate-to-vigorous physical activity, PA physical activity.CC BY · PubMed Central
Figure 2 Equivalence between pairs of monitors for sedentary time, light, moderate, and vigorous PA. Points represent the difference in min/day between a pair of monitors (as determined in the vertical axis) for every PA metric. Error bars represent the CI95% of the difference. Perfect equivalence = 0 (solid line); proposed equivalence zone (± 0.2 SDs of the differences) represented by dashed lines. Black markers indicate that the CI95% are within the equivalence zone, and grey markers indicate that they go beyond the equivalence zone. CI95% 95% confidence intervals, PA physical activity, SD standard deviation.
Figure 2 Equivalence between pairs of monitors for sedentary time, light, moderate, and vigorous PA. Points represent the difference in min/day between a pair of monitors (as determined in the vertical axis) for every PA metric. Error bars represent the CI95% of the difference. Perfect equivalence = 0 (solid line); proposed equivalence zone (± 0.2 SDs of the differences) represented by dashed lines. Black markers indicate that the CI95% are within the equivalence zone, and grey markers indicate that they go beyond the equivalence zone. CI95% 95% confidence intervals, PA physical activity, SD standard deviation.CC BY · PubMed Central
Figure 3 Attachment of the devices in two wristbands. The proximality of the wristbands was counterbalanced across participants.
Figure 3 Attachment of the devices in two wristbands. The proximality of the wristbands was counterbalanced across participants.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Research works printed but not linked: 1

  1. World Health Organization. Global Action Plan on Physical Activity 2018–2030: More Active People for a Healthier World (World Health Organization, 2018).

Cited by

See all 22

Metadata

Authors
Migueles, J. H., Molina-Garcia, P., Torres-Lopez, L. V., Cadenas-Sanchez, C., Rowlands, A. V., Ebner-Priemer, U. W., Koch, E. D., Reif, A., & Ortega, F. B.
Affiliations
  • Universidad de Granada (ES)
  • University of Leicester (GB)
  • Karlsruhe Institute of Technology (DE)
  • Goethe University Frankfurt (DE)
Corresponding author
  • Migueles, Jairo H.
  • Ortega, Francisco B.
Venue
Scientific Reports
Published
2022-04-01
Volume
12
Issue
1
Pages
5525-5525
ISSN
2045-2322 (ISSN-L)
OpenAlex
W4220804768
Cited by
22
References
42
Citations by year
2026: 3 · 2025: 7 · 2024: 6 · 2023: 6
FWCI
2.94
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • UniSA Research Outputs Repository (University of South Australia) (acceptedVersion, cc-by)
  • Repository KITopen (Karlsruhe Institute of Technology) (submittedVersion, cc-by)
  • Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion, cc-by)
  • Academica-e (Universidad Pública de Navarra) (submittedVersion, cc-by)
  • Jyväskylä University Digital Archive (University of Jyväskylä) (submittedVersion, cc-by)
  • Institutional Repository of the University of Granada (University of Granada) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Figshare (submittedVersion, cc-by)
  • Publication Server of Goethe University Frankfurt am Main (Goethe University Frankfurt) (submittedVersion, cc-by)
  • KITopen (cc-by)
Funders
  • Forskningsrådet om Hälsa, Arbetsliv och Välfärd (2021-00036)
  • Ministerio de Ciencia, Innovación y Universidades (FPU17/04802, FJC2018-037925-I)
  • NIHR Leicester Biomedical Research Centre
  • Collaboration for Leadership in Applied Health Research and Care - Greater Manchester
  • Horizon 2020 Framework Programme (667302)
  • Universidad de Granada (Units of Excellence; Scientific Excellence Unit on Exercise and Health (UCEES))
  • Junta de Andalucía (SOMM17/6107/UGR)
  • SAMID III network (RETICS)
  • ISCIII‐ Sub‐Directorate General for Research Assessment and Promotion
  • European Regional Development Fund (RD16/0022)
  • EXERNET Research Network on Exercise and Health (DEP2005‐00046/ACTI)
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
Keywords
accelerometer, wearable activity trackers, movement behavior, physical activity, sleep, sedentary behavior, moderate-to-vigorous physical activity, population surveillance, ActiGraph GT3X+, GENEActiv, wrist-worn sensors, physical activity guidelines, sleep guidelines
MeSH terms
Adult, Humans, Male, Population Surveillance, Wrist Joint, Reproducibility of Results, Exercise, Sedentary Behavior

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Equivalency of four research-grade movement sensors to assess movement behaviors and its implications for population surveillance. https://app.cochat.ai/papers/10.1038/s41598-022-09469-2
The paper
Migueles, J. H., Molina-Garcia, P., Torres-Lopez, L. V., Cadenas-Sanchez, C., Rowlands, A. V., Ebner-Priemer, U. W., Koch, E. D., Reif, A., & Ortega, F. B. (2022). Equivalency of four research-grade movement sensors to assess movement behaviors and its implications for population surveillance. Scientific Reports. https://doi.org/10.1038/s41598-022-09469-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.