The peripheral origin of tap-induced muscle contraction revealed by multi-electrode surface electromyography in human vastus medialis

Open access

The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index; none of the 2 sources its claims cite is checked for support yet.

Abstract

It is well established that muscle percussion may lead to the excitation of muscle fibres. It is still debated, however, whether the excitation arises directly at the percussion site or reflexively, at the end plates. Here we sampled surface electromyograms (EMGs) from multiple locations along human vastus medialis fibres to address this issue. In five healthy subjects, contractions were elicited by percussing the distal fibre endings at different intensities (5–50 N), and the patellar tendon. EMGs were detected with two 32-electrode arrays, positioned longitudinally and transversally to the percussed fibres, to detect the origin and the propagation of action potentials and their spatial distribution across vastus medialis. During muscle percussion, compound action potentials were first observed at the electrode closest to the tapping site with latency smaller than 5 ms, and spatial extension confined to the percussed strip. Conversely, during tendon tap (and voluntary contractions), action potentials were first detected by electrodes closest to end plates and at a greater latency (mean ± s.d., 28.2 ± 1.7 ms, p < 0.001). No evidence of reflex responses to muscle tap was observed. Multi-electrode surface EMGs allowed for the first time to unequivocally and quantitatively describe the non-reflex nature of the response evoked by a muscle tap.

Overview

CoChat Summary

TL;DR

Multi-electrode surface EMG in human vastus medialis shows that gentle muscle tap evokes action potentials first at the percussion site, propagating unidirectionally toward the proximal end, whereas tendon tap evokes potentials at the innervation zone with bidirectional propagation. The authors conclude that tap-induced contraction is idiomuscular/peripheral rather than reflex under these conditions.

Key findings

  • Muscle-tap potentials were first detected at the most distal electrode (electrode 1) in all 180 taps, while tendon-tap potentials originated at the innervation zone; muscle-tap propagation was unidirectional, tendon-tap and voluntary-contraction propagation was bidirectional.
  • Latency was much shorter for muscle tap than tendon tap: mean ± s.d. 3.6 ± 1.7 ms vs. 28.2 ± 1.7 ms, with significant within-subject differences (p < 0.001 for all subjects); at innervation-zone channel 9, muscle-tap latency was 18.6 ± 1.9 ms vs. 28.2 ± 1.7 ms for tendon tap.
  • The lowest tap force eliciting EMG above background ranged from 5.6 N (Subject 1) to 11.3 N (Subject 2); the W1 amplitude increased linearly with tap force (Pearson r > 0.93; p < 0.001 for all subjects), while W2, the expected reflex window, did not exceed background noise at any tap force.
  • Transverse-array responses were centered mid-array (mean [range]: 8.3 [7.5–9.5] cm) with average dispersion of 2 cm [1.0–3.8] cm, indicating excitation confined to the percussed muscle strip.

Methods

  • Five healthy male volunteers (age 41 ± 5 years, height 179 ± 4 cm, weight 72 ± 5 kg) participated in three sessions: voluntary knee extension, patellar tendon tap, and muscle taps at 5–50 N delivered to the distal vastus medialis; 23–35 muscle taps per subject.
  • Surface EMG was recorded with two 32-electrode arrays, one longitudinal and one transverse to the muscle fibres (5-mm inter-electrode distance; monopolar, 2048 Hz, gain 192 V/V), after identifying the innervation zone during voluntary contractions.
  • Analysis assessed propagation direction via delays between consecutive single-differential signals, latency from tap onset to first EMG potential, RMS amplitude in windows W1 and W2, and Gaussian fitting of transverse RMS distributions; non-parametric tests (Mann-Whitney) and Pearson correlation were used.

Limitations

  • Stated: the mechanisms underlying tap-evoked muscle fibre excitation were not investigated and cannot be inferred from the results; no repetitive firing was detected, possibly because it is occasional and asynchronous.
  • Stated: the absence of a reflex response may depend on factors such as muscle anatomy, amount of muscle mass affected, hammer-head size, muscle length, spindle stretch, background contraction, and the fraction of muscle mass stimulated.
  • Evident: the sample was small (five healthy male volunteers) and limited to vastus medialis, so generalizability to other muscles, women, older adults, or clinical populations is not established; the mechano-sensitive channel explanation is speculative and not directly tested.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41598-020-59122-z

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Figure 1 Experimental setup and possible EMG propagation patterns. (a) Schematic representation of the experimental setup. Medial view of the human left thigh. Two linear arrays of 32 electrodes (5 mm inter-electrode distance) were positioned longitudinally and transversally with respect to the distal fibres of the vastus medialis (VM) muscle. Muscle taps were delivered at the distal end of the longitudinal electrode array. (b) Generation and propagation patterns of EMG potentials associated with the direct idiomuscular (dashed arrow) and reflex (solid arrows) activation of VM fibres, as detected by the longitudinal array of electrodes. The latencies L (Lidio and Lreflex) between the tap onset and the first detected EMG potentials are shown on the time axis. W1 and W2 are the time windows, within which the amplitudes of the idiomuscular and reflex responses were evaluated, respectively (see methods).
Figure 1 Experimental setup and possible EMG propagation patterns. (a) Schematic representation of the experimental setup. Medial view of the human left thigh. Two linear arrays of 32 electrodes (5 mm inter-electrode distance) were positioned longitudinally and transversally with respect to the distal fibres of the vastus medialis (VM) muscle. Muscle taps were delivered at the distal end of the longitudinal electrode array. (b) Generation and propagation patterns of EMG potentials associated with the direct idiomuscular (dashed arrow) and reflex (solid arrows) activation of VM fibres, as detected by the longitudinal array of electrodes. The latencies L (Lidio and Lreflex) between the tap onset and the first detected EMG potentials are shown on the time axis. W1 and W2 are the time windows, within which the amplitudes of the idiomuscular and reflex responses were evaluated, respectively (see methods).CC BY · PubMed Central
Figure 2 Patterns of propagation of the EMG signal. (a) Propagation patterns of experimental, single-differential (SD) EMG responses detected with the longitudinal electrode array in the three experimental conditions: muscle tap (MT), tendon tap (TT), and voluntary contraction. The tap onset is indicated by a red arrow in the two panels showing the responses to percussions (MT and TT). IZ indicates the innervation zone position as identified in voluntary and tendon tap contractions. (b) EMG potentials induced by muscle tap (solid line) and by tendon tap (dashed line). The two grey-shaded boxes around EMG responses picked up by electrode 5 indicate the two time windows (W1 and W2), in which the amplitudes of the idiomuscular (W1) and reflex (W2) responses were evaluated.
Figure 2 Patterns of propagation of the EMG signal. (a) Propagation patterns of experimental, single-differential (SD) EMG responses detected with the longitudinal electrode array in the three experimental conditions: muscle tap (MT), tendon tap (TT), and voluntary contraction. The tap onset is indicated by a red arrow in the two panels showing the responses to percussions (MT and TT). IZ indicates the innervation zone position as identified in voluntary and tendon tap contractions. (b) EMG potentials induced by muscle tap (solid line) and by tendon tap (dashed line). The two grey-shaded boxes around EMG responses picked up by electrode 5 indicate the two time windows (W1 and W2), in which the amplitudes of the idiomuscular (W1) and reflex (W2) responses were evaluated.CC BY · PubMed Central
Figure 3 Delays between consecutive single differential EMG signals computed along the fibre direction. Boxplots represent the delay distribution obtained from voluntary contractions (grey boxes) and from muscle taps (MT, white boxes) for all subjects. The sign of the delay depends on the propagation direction. Delays with constant sign along the entire array indicate unidirectional propagation, while a sign change denotes bi-directional propagation. Dashed lines indicate the range of physiological delays associated with a conduction velocity between 3 and 6 m/s. An attenuation of action potentials along the fibres could be observed for all subjects (e.g. Fig. 2a) possibly because of misalignment between fibres and electrodes24 and difference in propagation velocity between excited fibres39. Therefore the delay values are represented for the maximal number of consecutive channels (n = 16) for which we were able to successfully track the propagation of action potentials.
Figure 3 Delays between consecutive single differential EMG signals computed along the fibre direction. Boxplots represent the delay distribution obtained from voluntary contractions (grey boxes) and from muscle taps (MT, white boxes) for all subjects. The sign of the delay depends on the propagation direction. Delays with constant sign along the entire array indicate unidirectional propagation, while a sign change denotes bi-directional propagation. Dashed lines indicate the range of physiological delays associated with a conduction velocity between 3 and 6 m/s. An attenuation of action potentials along the fibres could be observed for all subjects (e.g. Fig. 2a) possibly because of misalignment between fibres and electrodes24 and difference in propagation velocity between excited fibres39. Therefore the delay values are represented for the maximal number of consecutive channels (n = 16) for which we were able to successfully track the propagation of action potentials.CC BY · PubMed Central
Figure 4 Latencies between the tap and EMG onsets for muscle tap (MT) and tendon tap (TT). Data is shown for each individual subject. Note the broken ordinate. (**p < 0.001, Mann-Withney test).
Figure 4 Latencies between the tap and EMG onsets for muscle tap (MT) and tendon tap (TT). Data is shown for each individual subject. Note the broken ordinate. (**p < 0.001, Mann-Withney test).CC BY · PubMed Central
Figure 5 Effect of the muscle-tap force on the induced EMG amplitude for each participant. RMS values were computed for two windows (W1 and W2, see Fig. 2) defined as the time intervals where the induced potential was expected to appear if induced at the muscle tap location (W1) or through a reflex (at the IZ channel – W2). For each graph, the dashed horizontal line indicates the background noise level, while the solid line is the regression line fitting RMS estimates in W1. Pearson correlation coefficients (r) are reported within each scatter plot.
Figure 5 Effect of the muscle-tap force on the induced EMG amplitude for each participant. RMS values were computed for two windows (W1 and W2, see Fig. 2) defined as the time intervals where the induced potential was expected to appear if induced at the muscle tap location (W1) or through a reflex (at the IZ channel – W2). For each graph, the dashed horizontal line indicates the background noise level, while the solid line is the regression line fitting RMS estimates in W1. Pearson correlation coefficients (r) are reported within each scatter plot.CC BY · PubMed Central
Figure 6 Transversal distribution of the EMG signal in response to muscle tap. (a) Amplitude distributions of the EMG responses induced by muscle tap and detected by the transversal electrode array for one representative subject. Different traces represent the amplitude distributions for different muscle tap forces. The abscissa refers to the numbers of electrodes and therefore spans 16 cm. (b) Average values of means and standard deviations of the Gaussian distributions fitting the transversal amplitude profiles for all subjects and tap forces. The ordinate refers to the medio-lateral position along the transversal electrode array (med = medial; lat = lateral).
Figure 6 Transversal distribution of the EMG signal in response to muscle tap. (a) Amplitude distributions of the EMG responses induced by muscle tap and detected by the transversal electrode array for one representative subject. Different traces represent the amplitude distributions for different muscle tap forces. The abscissa refers to the numbers of electrodes and therefore spans 16 cm. (b) Average values of means and standard deviations of the Gaussian distributions fitting the transversal amplitude profiles for all subjects and tap forces. The ordinate refers to the medio-lateral position along the transversal electrode array (med = medial; lat = lateral).CC BY · PubMed Central

Verification

Claims the paper makes

0 Valid · 1 Not valid · 2 Not checked · 37 Own results and interpretations

16 more claims

Create a free account to see all 40 claims and to verify the 2 references still open.

See all claims — free account
  • It may state two separate claims as one. 13
  • Probably not a substantial claim. 10

Create a free account to see these claims.

Citations

Cites

Show all 38 references

Research works printed but not linked: 2

  1. Hong, C. Z., Torigoe, Y. & Yu, J. The localized twitch responses in respinsive taut bands of rabbits skeletal muscle fibers are related to the reflexes at spinal cord level. J Musculoskel. Pain. 3, 15–33 (1995).
  2. Simons, D. G., Travell, J. G. & Simons, L. S. Myofascial pain and dysfunction. The trigger point manual. 2nd edn, Vol. 1 Upper half of the body (Williams & Wilkins, 1999).

Cited by

See all 4

Metadata

Authors
Botter, A., Vieira, T. M., Geri, T., & Roatta, S.
Affiliations
  • Politecnico di Torino (IT)
  • University of Genoa (IT)
  • University of Turin (IT)
Corresponding author
Roatta, Silvestro
Venue
Scientific Reports
Published
2020-02-10
Volume
10
Issue
1
Pages
2256-2256
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3005047740
Cited by
4
References
38
Citations by year
2024: 1 · 2023: 1 · 2022: 1 · 2021: 1
FWCI
0.24
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PORTO@Iris (submittedVersion, cc-by)
  • Institutional Research Information System University of Turin (University of Turin) (submittedVersion, other-oa)
Funders
  • Compagnia di San Paolo (Convenzione_CSP_2016_2018)
  • Università degli Studi di Torino (ROAS_RILO_17_01)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
  • Health Sciences › Medicine › Clinical Neurology › Peripheral Nerve Disorders
Keywords
vastus medialis, compound action potential, action potential propagation, reflexes, end plates, voluntary muscle contraction
MeSH terms
Action Potentials, Adult, Electromyography, Humans, Male, Middle Aged, Muscle Contraction, Tendons, Muscle Fibers, Skeletal, Quadriceps Muscle, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-10-11, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-11 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The peripheral origin of tap-induced muscle contraction revealed by multi-electrode surface electromyography in human vastus medialis. https://app.cochat.ai/papers/10.1038/s41598-020-59122-z
The paper
Botter, A., Vieira, T. M., Geri, T., & Roatta, S. (2020). The peripheral origin of tap-induced muscle contraction revealed by multi-electrode surface electromyography in human vastus medialis. Scientific Reports. https://doi.org/10.1038/s41598-020-59122-z

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.