Comparison between a wireless dry electrode EEG system with a conventional wired wet electrode EEG system for clinical applications
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Dry electrode electroencephalogram (EEG) recording combined with wireless data transmission offers an alternative tool to conventional wet electrode EEG systems. However, the question remains whether the signal quality of dry electrode recordings is comparable to wet electrode recordings in the clinical context. We recorded the resting state EEG (rsEEG), the visual evoked potentials (VEP) and the visual P300 (P3) from 16 healthy subjects (age range: 26–79 years) and 16 neurological patients who reported subjective memory impairment (age range: 50–83 years). Each subject took part in two recordings on different days, one with 19 dry electrodes and another with 19 wet electrodes. They reported their preferred EEG system. Comparisons of the rsEEG recordings were conducted qualitatively by independent visual evaluation by two neurologists blinded to the EEG system used and quantitatively by spectral analysis of the rsEEG. The P100 visual evoked potential (VEP) and P3 event-related potential (ERP) were compared in terms of latency, amplitude and pre-stimulus noise. The majority of subjects preferred the dry electrode headset. Both neurologists reported that all rsEEG traces were comparable between the wet and dry electrode headsets. Absolute Alpha and Beta power during rest did not statistically differ between the two EEG systems (p > 0.05 in all cases). However, Theta and Delta power was slightly higher with the dry electrodes (p = 0.0004 for Theta and p < 0.0001 for Delta). For ERPs, the mean latencies and amplitudes of the P100 VEP and P3 ERP showed comparable values (p > 0.10 in all cases) with a similar spatial distribution for both wet and dry electrode systems. These results suggest that the signal quality, ease of set-up and portability of the dry electrode EEG headset used in our study comply with the needs of clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
The control of the false discovery rate in multiple testing under dependency
Benjamini, Y., & Yekutieli, D. (2001) · The Annals of Statistics · doi:10.1214/aos/1013699998 · Cited by 10,490
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
An Introduction to Applied Geostatistics
Bilonick, R. A. (1991) · Technometrics · doi:10.1080/00401706.1991.10484886 · Cited by 4,593
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Green, A. A., Berman, M., Switzer, P., & Craig, M. D. (1988) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/36.3001 · Cited by 2,615
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
Using the International 10-20 EEG System for Positioning of Transcranial Magnetic Stimulation
Herwig, U., Satrapi, P., & Schönfeldt-Lecuona, C. (2003) · Brain Topography · doi:10.1023/b:brat.0000006333.93597.9d · Cited by 1,098
EEG differences between eyes-closed and eyes-open resting conditions
Barry, R. J., Clarke, A. R., Johnstone, S. J., Magee, C. A., & Rushby, J. A. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.07.028 · Cited by 1,077
The P300: Where in the Brain Is It Produced and What Does It Tell Us?
Linden, D. E. J. (2005) · The Neuroscientist · doi:10.1177/1073858405280524 · Cited by 833
Cited by
Progress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
Past, Present, and Future of EEG-Based BCI Applications
Värbu, K., Muhammad, N., & Muhammad, Y. (2022) · Sensors · doi:10.3390/s22093331 · Cited by 321
Karoly, P. J., Rao, V. R., Gregg, N. M., Worrell, G. A., Bernard, C., Cook, M. J., & Baud, M. O. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-021-00464-1 · Cited by 262
Wireless EEG: A survey of systems and studies
Niso, G., Romero, E., Moreau, J. T., Araujo, A., & Krol, L. R. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2022.119774 · Cited by 244
Electroencephalography (EEG) Technology Applications and Available Devices
Soufineyestani, M., Dowling, D., & Khan, A. (2020) · Applied Sciences · doi:10.3390/app10217453 · Cited by 230
“Conductive solid gel materials, such as those produced by Enobio, have also been used successfully in EEG devices.”
BackgroundMethodImpedance and Noise of Passive and Active Dry EEG Electrodes: A Review
Habibzadeh Tonekabony Shad, E., Molinas, M., & Ytterdal, T. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3012394 · Cited by 173
“Due to huge progress in dry electrodes technology, they comply with the needs of clinical EEG applications and higher user comfort is achieved for dry electrodes in comparison with wet electrodes [95]–[97].”
BackgroundDecoding Covert Speech From EEG-A Comprehensive Review
Panachakel, J. T., & Ramakrishnan, A. G. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.642251 · Cited by 156
“Although recent studies have shown comparable signal qualities in wet and dry electrodes (Lopez-Gordo et al., 2014; Hinrichs et al., 2020), EEG recorded using dry electrodes are more prone to artifacts (Leach et al., 2020).”
BackgroundDementia ConnEEGtome: towards multicentric harmonization of EEG connectivity in neurodegeneration
Prado, P., Birba, A., Cruzat, J., Santamaría-García, H., Parra, M., Moguilner, S., Tagliazucchi, E., & Ibáñez, A. (2022) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2021.12.008 · Cited by 43
A Fully-Analogue Light-to-Frequency Converter Circuit for Optical Sensing Applications
Stanchieri, G. D. P., De Marcellis, A., Faccio, M., Palange, E., & Guler, U. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3187943 · Cited by 11
Metadata
- Authors
- Hinrichs, H., Scholz, M., Baum, A. K., Kam, J. W. Y., Knight, R. T., & Heinze, H.-J.
- Venue
- Scientific Reports
- Published
- 2020-03-23
- Volume
- 10
- Issue
- 1
- Pages
- 5218-5218
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3012589689
- Cited by
- 219
- References
- 51
- FWCI
- 13.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.