A Fully-Analogue Light-to-Frequency Converter Circuit for Optical Sensing Applications
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
This paper reports on a novel analog front-end circuit designed to measure light intensity variations for portable/wearable and implantable sensor applications in different fields spanning from industry to biomedicine. The circuit is capable to follow variations of light intensity detected by a photodiode through the frequency modulation of a generated square wave output voltage signal. Therefore, the circuit can be seen as a light-to-frequency converter allowing for a quasi-digital output that can be measured by simple digital frequency meters so avoiding the use of transimpedance amplifiers and analog-to-digital converters. The proposed architecture of the analog front-end circuit has been designed at the transistor level in TSMC 180 nm standard CMOS technology in CADENCE Design System environment. The resulting characteristics and performances have been studied both theoretically and numerically. Moreover, a simplified version of the proposed circuit has been also implemented by using commercial off-the-shelf discrete components to study experimentally its main features. In this sense, the paper presents a series of experimental findings that fully validate the solution and prove its performances in terms of sensitivity and resolution as well as of time response to light intensity variations by using a laser operating in both steady-state and pulsed regimes. By varying the laser power up to $3.75~\mu \text{W}$ , the resulting circuit sensitivity and resolution are equal to…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Biosensing with plasmonic nanosensors
Anker, J. N., Hall, W. P., Lyandres, O., Shah, N. C., Zhao, J., & Van Duyne, R. P. (2008) · Nature Materials · doi:10.1038/nmat2162 · Cited by 6,786
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Wu, C., Khanikaev, A. B., Adato, R., Arju, N., Yanik, A. A., Altug, H., & Shvets, G. (2012) · Nature Materials · doi:10.1038/nmat3161 · Cited by 1,045
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Advances in healthcare wearable devices
Iqbal, S. M. A., Mahgoub, I., Du, E., Leavitt, M. A., & Asghar, W. (2021) · npj Flexible Electronics · doi:10.1038/s41528-021-00107-x · Cited by 714
Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624
Optical aptasensors for quantitative detection of small biomolecules: A review
Feng, C., Dai, S., & Wang, L. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.03.014 · Cited by 300
Holographic metasurface gas sensors for instantaneous visual alarms
Kim, I., Kim, W.-S., Kim, K., Ansari, M. A., Mehmood, M. Q., Badloe, T., Kim, Y., Gwak, J., Lee, H., Kim, Y.-K., et al. (2021) · Science Advances · doi:10.1126/sciadv.abe9943 · Cited by 281
Wearable devices for the detection of COVID-19
Ates, H. C., Yetisen, A. K., Güder, F., & Dincer, C. (2021) · Nature Electronics · doi:10.1038/s41928-020-00533-1 · Cited by 251
Two New “Protected” Oxyphors for Biological Oximetry: Properties and Application in Tumor Imaging
Esipova, T. V., Karagodov, A., Miller, J., Wilson, D. F., Busch, T. M., & Vinogradov, S. A. (2011) · Analytical Chemistry · doi:10.1021/ac2022234 · Cited by 247
Cited by
Stanchieri, G. D. P., Marcellis, A. D., Faccio, M., Palange, E., & Aiello, O. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3527759 · Cited by 8
“…photocurrent is used as the input of a transimpedance amplifier (TIA) combined with an analog-to-digital converter (ADC) [9], [10] circuit and 2) a converter circuit with a quasi-digital solution is used to generate a voltage waveform whose frequency depends on the input PD photocurrent [11], [12].”
Self-citationPolymer–Perovskite Microcrystal Heterojunction for Self-Powered Optical Sensing and Communication
Sathyanarayana, S., & Das, B. C. (2026) · Advanced Materials · doi:10.1002/adma.202517950 · Cited by 7
A 0.18 μm CMOS Integrated Optical Wireless Power Transfer System for Implantable Biomedical Devices
Stanchieri, G. D. P., Marcellis, A. D., Faccio, M., Palange, E., & Güler, Ü. (2023) · International Conference Mixed Design of Integrated Circuits and Systems · doi:10.23919/mixdes58562.2023.10203250 · Cited by 7
Self-citationA 30 kHz - 3 GHz Clock Duty-Cycle Corrector Circuit for CMOS Integrated Digital Electronic Systems
Stanchieri, G. D. P., Marcellis, A. D., Faccio, M., Palange, E., & Aiello, O. (2023) · International Conference Mixed Design of Integrated Circuits and Systems · doi:10.23919/mixdes58562.2023.10203264 · Cited by 4
Self-citationA reduced effort design, low power, extremely compact, CMOS ADC based on voltage-to-time converter
Stanchieri, G. D. P., Aiello, O., & Marcellis, A. D. (2025) · AEU - International Journal of Electronics and Communications · doi:10.1016/j.aeue.2025.155790 · Cited by 3
Self-citation
Metadata
- Authors
- Stanchieri, G. D. P., De Marcellis, A., Faccio, M., Palange, E., & Guler, U.
- Affiliations
- University of L'Aquila (IT)
- Department of Industrial and Information Engineering and Economics (DIIIE), University of L’Aquila, L’Aquila, Italy
- Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
- Venue
- IEEE Sensors Journal
- Published
- 2022-08-15
- Volume
- 22
- Issue
- 16
- Pages
- 16120-16130
- ISSN
- 1530-437X (ISSN-L)
- 1558-1748
- 2379-9153
- OpenAlex
- W4285259100
- Semantic Scholar
- 5a8b33fd29458dd83118fff71166629714037e92
- Cited by
- 11
- References
- 58
- Citations by year
- 2025: 6 · 2024: 2 · 2023: 2 · 2022: 1
- FWCI
- 0.80
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Sensors Journal (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
- Keywords
- analog front-end, photodiode, light intensity measurement, wearable sensors, implantable sensors, 0.18 μm CMOS
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fully-Analogue Light-to-Frequency Converter Circuit for Optical Sensing Applications. https://app.cochat.ai/papers/10.1109/jsen.2022.3187943
- The paper
- Stanchieri, G. D. P., De Marcellis, A., Faccio, M., Palange, E., & Guler, U. (2022). A Fully-Analogue Light-to-Frequency Converter Circuit for Optical Sensing Applications. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2022.3187943
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.