CoChat

A Fully-Analogue Light-to-Frequency Converter Circuit for Optical Sensing Applications

Stanchieri, Guido Di Patrizio, De Marcellis, Andrea, Faccio, Marco, Palange, Elia, Guler, Ulkuhan · 2022 · IEEE Sensors Journal

The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.

Abstract

This paper reports on a novel analog front-end circuit designed to measure light intensity variations for portable/wearable and implantable sensor applications in different fields spanning from industry to biomedicine. The circuit is capable to follow variations of light intensity detected by a photodiode through the frequency modulation of a generated square wave output voltage signal. Therefore, the circuit can be seen as a light-to-frequency converter allowing for a quasi-digital output that can be measured by simple digital frequency meters so avoiding the use of transimpedance amplifiers and analog-to-digital converters. The proposed architecture of the analog front-end circuit has been designed at the transistor level in TSMC 180 nm standard CMOS technology in CADENCE Design System environment. The resulting characteristics and performances have been studied both theoretically and numerically. Moreover, a simplified version of the proposed circuit has been also implemented by using commercial off-the-shelf discrete components to study experimentally its main features. In this sense, the paper presents a series of experimental findings that fully validate the solution and prove its performances in terms of sensitivity and resolution as well as of time response to light intensity variations by using a laser operating in both steady-state and pulsed regimes. By varying the laser power up to $3.75~\mu \text{W}$ , the resulting circuit sensitivity and resolution are equal to…

Overview

Integrity signals

Registry

Crossref · 10.1109/jsen.2022.3187943

Cites

58 of 58 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 58 references

Cited by

See all 11

Metadata

Authors
Stanchieri, G. D. P., De Marcellis, A., Faccio, M., Palange, E., & Guler, U.
Affiliations
  • University of L'Aquila (IT)
  • Department of Industrial and Information Engineering and Economics (DIIIE), University of L’Aquila, L’Aquila, Italy
  • Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, MA, USA
Venue
IEEE Sensors Journal
Published
2022-08-15
Volume
22
Issue
16
Pages
16120-16130
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W4285259100
Cited by
11
References
58
Citations by year
2025: 6 · 2024: 2 · 2023: 2 · 2022: 1
FWCI
0.80
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Sensors Journal (publishedVersion)
  • Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
Keywords
analog front-end, photodiode, light intensity measurement, wearable sensors, implantable sensors, 0.18 μm CMOS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Fully-Analogue Light-to-Frequency Converter Circuit for Optical Sensing Applications. https://app.cochat.ai/papers/10.1109/jsen.2022.3187943
The paper
Stanchieri, G. D. P., De Marcellis, A., Faccio, M., Palange, E., & Guler, U. (2022). A Fully-Analogue Light-to-Frequency Converter Circuit for Optical Sensing Applications. IEEE Sensors Journal. https://doi.org/10.1109/jsen.2022.3187943

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.