Comparison between a wireless dry electrode EEG system with a conventional wired wet electrode EEG system for clinical applications
Open accessThe DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Abstract
Dry electrode electroencephalogram (EEG) recording combined with wireless data transmission offers an alternative tool to conventional wet electrode EEG systems. However, the question remains whether the signal quality of dry electrode recordings is comparable to wet electrode recordings in the clinical context. We recorded the resting state EEG (rsEEG), the visual evoked potentials (VEP) and the visual P300 (P3) from 16 healthy subjects (age range: 26–79 years) and 16 neurological patients who reported subjective memory impairment (age range: 50–83 years). Each subject took part in two recordings on different days, one with 19 dry electrodes and another with 19 wet electrodes. They reported their preferred EEG system. Comparisons of the rsEEG recordings were conducted qualitatively by independent visual evaluation by two neurologists blinded to the EEG system used and quantitatively by spectral analysis of the rsEEG. The P100 visual evoked potential (VEP) and P3 event-related potential (ERP) were compared in terms of latency, amplitude and pre-stimulus noise. The majority of subjects preferred the dry electrode headset. Both neurologists reported that all rsEEG traces were comparable between the wet and dry electrode headsets. Absolute Alpha and Beta power during rest did not statistically differ between the two EEG systems (p > 0.05 in all cases). However, Theta and Delta power was slightly higher with the dry electrodes (p = 0.0004 for Theta and p < 0.0001 for Delta). For ERPs, the mean latencies and amplitudes of the P100 VEP and P3 ERP showed comparable values (p > 0.10 in all cases) with a similar spatial distribution for both wet and dry electrode systems. These results suggest that the signal quality, ease of set-up and portability of the dry electrode EEG headset used in our study comply with the needs of clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
The control of the false discovery rate in multiple testing under dependency
Benjamini, Y., & Yekutieli, D. (2001) · The Annals of Statistics · doi:10.1214/aos/1013699998 · Cited by 10,490
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
An Introduction to Applied Geostatistics
Bilonick, R. A. (1991) · Technometrics · doi:10.1080/00401706.1991.10484886 · Cited by 4,593
Report of the committee on methods of clinical examination in electroencephalography
(1958) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(58)90053-1 · Cited by 2,717
Green, A. A., Berman, M., Switzer, P., & Craig, M. D. (1988) · IEEE Transactions on Geoscience and Remote Sensing · doi:10.1109/36.3001 · Cited by 2,615
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
Using the International 10-20 EEG System for Positioning of Transcranial Magnetic Stimulation
Herwig, U., Satrapi, P., & Schönfeldt-Lecuona, C. (2003) · Brain Topography · doi:10.1023/b:brat.0000006333.93597.9d · Cited by 1,098
EEG differences between eyes-closed and eyes-open resting conditions
Barry, R. J., Clarke, A. R., Johnstone, S. J., Magee, C. A., & Rushby, J. A. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.07.028 · Cited by 1,077
The P300: Where in the Brain Is It Produced and What Does It Tell Us?
Linden, D. E. J. (2005) · The Neuroscientist · doi:10.1177/1073858405280524 · Cited by 833
How about taking a low‐cost, small, and wireless EEG for a walk?
Debener, S., Minow, F., Emkes, R., Gandras, K., & de Vos, M. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01471.x · Cited by 540
The effects of electrode impedance on data quality and statistical significance in ERP recordings
Kappenman, E. S., & Luck, S. J. (2010) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01009.x · Cited by 447
Lopez-Gordo, M., Sanchez-Morillo, D., & Valle, F. (2014) · Sensors · doi:10.3390/s140712847 · Cited by 410
Prefrontal modulation of visual processing in humans
Barceló, F., Suwazono, S., & Knight, R. T. (2000) · Nature Neuroscience · doi:10.1038/73975 · Cited by 374
Self-citationP300 Clinical Utility and Control of Variability
Polich, J. (1998) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199801000-00004 · Cited by 342
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
Liao, L.-D., Chen, C.-Y., Wang, I.-J., Chen, S.-F., Li, S.-Y., Chen, B.-W., Chang, J.-Y., & Lin, C.-T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-5 · Cited by 258
Soft, Comfortable Polymer Dry Electrodes for High Quality ECG and EEG Recording
Chen, Y.-H., De Beeck, M., Vanderheyden, L., Carrette, E., Mihajlović, V., Vanstreels, K., Grundlehner, B., Gadeyne, S., Boon, P., & Van Hoof, C. (2014) · Sensors · doi:10.3390/s141223758 · Cited by 238
Making the case for mobile cognition: EEG and sports performance
Park, J. L., Fairweather, M. M., & Donaldson, D. I. (2015) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2015.02.014 · Cited by 210
Comparison of Dry and Gel Based Electrodes for P300 Brain–Computer Interfaces
Guger, C., Krausz, G., Allison, B. Z., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00060 · Cited by 190
Kam, J. W. Y., Griffin, S., Shen, A., Patel, S., Hinrichs, H., Heinze, H.-J., Deouell, L. Y., & Knight, R. T. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.012 · Cited by 188
Self-citationA new EEG recording system for passive dry electrodes
Gargiulo, G., Calvo, R. A., Bifulco, P., Cesarelli, M., Jin, C., Mohamed, A., & van Schaik, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.12.025 · Cited by 165
Novel Multipin Electrode Cap System for Dry Electroencephalography
Fiedler, P., Pedrosa, P., Griebel, S., Fonseca, C., Vaz, F., Supriyanto, E., Zanow, F., & Haueisen, J. (2015) · Brain Topography · doi:10.1007/s10548-015-0435-5 · Cited by 145
Signal Quality Evaluation of Emerging EEG Devices
Radüntz, T. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00098 · Cited by 129
Systems, Subjects, Sessions: To What Extent Do These Factors Influence EEG Data?
Melnik, A., Legkov, P., Izdebski, K., Kärcher, S. M., Hairston, W. D., Ferris, D. P., & König, P. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00150 · Cited by 127
Proposing Metrics for Benchmarking Novel EEG Technologies Towards Real-World Measurements
Oliveira, A. S., Schlink, B. R., Hairston, W. D., König, P., & Ferris, D. P. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00188 · Cited by 120
Contact Pressure and Flexibility of Multipin Dry EEG Electrodes
Fiedler, P., Mühle, R., Griebel, S., Pedrosa, P., Fonseca, C., Vaz, F., Zanow, F., & Haueisen, J. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2811752 · Cited by 104
Guideline Twelve: Guidelines for Long-Term Monitoring for Epilepsy
(2008) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0b013e318175d472 · Cited by 101
A high-speed brain-computer interface (BCI) using dry EEG electrodes
Spüler, M. (2017) · PLoS ONE · doi:10.1371/journal.pone.0172400 · Cited by 101
EEG From a Single-Channel Dry-Sensor Recording Device
Johnstone, S. J., Blackman, R., & Bruggemann, J. M. (2012) · Clinical EEG and Neuroscience · doi:10.1177/1550059411435857 · Cited by 98
A Topographic Study of ERPs Elicited by Visual Feature Discrimination
O’Donnell, B. F., Swearer, J. M., Smith, L. T., Hokama, H., & McCarley, R. W. (1997) · Brain Topography · doi:10.1023/a:1022203811678 · Cited by 98
Zander, T. O., Andreessen, L. M., Berg, A., Bleuel, M., Pawlitzki, J., Zawallich, L., Krol, L. R., & Gramann, K. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00078 · Cited by 97
Shestyuk, A. Y., Kasinathan, K., Karapoondinott, V., Knight, R. T., & Gurumoorthy, R. (2019) · PLoS ONE · doi:10.1371/journal.pone.0214507 · Cited by 94
Self-citationCruz-Garza, J. G., Brantley, J. A., Nakagome, S., Kontson, K. L., Megjhani, M., Robleto, D., & Contreras-Vidal, J. L. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00527 · Cited by 86
Askamp, J., & van Putten, M. J. A. M. (2013) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2013.09.002 · Cited by 86
Ambulatory EEG: a cost‐effective alternative to inpatient video‐EEG in adult patients
Dash, D., Hernández‐Ronquillo, L., Moien‐Afshari, F., & Tellez-Zenteno, J. F. (2012) · Epileptic Disorders · doi:10.1684/epd.2012.0529 · Cited by 79
A low-power, wireless, 8-channel EEG monitoring headset
Brown, L., van de Molengraft, J., Yazıcıoğlu, R. F., Torfs, T., Penders, J., & Hoof, C. A. V. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627393 · Cited by 74
Computerized recognition of persons by EEG spectral patterns
Stassen, H. H. (1980) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(80)90368-5 · Cited by 69
Test–retest reliability of EEG spectra during a working memory task
Näpflin, M., Wildi, M., & Sarnthein, J. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.08.028 · Cited by 61
Käthner, I., Halder, S., Hintermüller, C., Espinosa, A., Guger, C., Miralles, F., Vargiu, E., Dauwalder, S., Rafael-Palou, X., Solà, M., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00286 · Cited by 51
Alterations of the human electroencephalogram induced by stressful verbal activity
Berkhout, J., Walter, D. O., & ADEY, W. R. (1969) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(69)90186-2 · Cited by 49
Contribution of Subregions of Human Frontal Cortex to Novelty Processing
Løvstad, M., Funderud, I., Lindgren, M., Endestad, T., Due-Tønnessen, P., Meling, T., Voytek, B., Knight, R. T., & Solbakk, A.-K. (2012) · Journal of Cognitive Neuroscience · doi:10.1162/jocn_a_00099 · Cited by 46
Self-citationA Wearable Channel Selection-Based Brain-Computer Interface for Motor Imagery Detection
Lo, C.-C., Chien, T.-Y., Chen, Y., Tsai, S.-H. L., Fang, W.-C., & Lin, B. (2016) · Sensors · doi:10.3390/s16020213 · Cited by 38
Nathan, V., & Jafari, R. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2471080 · Cited by 34
myBrain: a novel EEG embedded system for epilepsy monitoring
Pinho, F., Cerqueira, J., Correia, J. H., Sousa, N., & Dias, N. S. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1382585 · Cited by 29
Clements, J. M., Sellers, E. W., Ryan, D. B., Caves, K. M., Collins, L. M., & Throckmorton, C. S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066018 · Cited by 25
Quality assessment of electroencephalography obtained from a “dry electrode” system
Slater, J. D., Kalamangalam, G. P., & Hope, O. A. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.05.011 · Cited by 25
What Is the Importance of Abnormal “Background” Activity in Seizure Generation?
Staba, R. J., & Worrell, G. A. (2014) · Advances in experimental medicine and biology · doi:10.1007/978-94-017-8914-1_3 · Cited by 21
A Preliminary Study on Precision Image Guidance for Electrode Placement in an EEG Study
Jeon, S., Chien, J., Song, C., & Hong, J. (2017) · Brain Topography · doi:10.1007/s10548-017-0610-y · Cited by 21
Maciejewska, K., & Drzazga, Z. K. (2019) · Acta Neurobiologiae Experimentalis · doi:10.21307/ane-2019-003 · Cited by 8
Distribution of Variables Extracted from Spectral EEG-Analysis
Ferber, G., & Eichholz, G. (1976) · Methods of Information in Medicine · doi:10.1055/s-0038-1635726 · Cited by 4
Cited by
Progress in Brain Computer Interface: Challenges and Opportunities
Saha, S., Mamun, K. A., Ahmed, K., Mostafa, R., Naik, G. R., Darvishi, S., Khandoker, A. H., & Baumert, M. (2021) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2021.578875 · Cited by 365
Past, Present, and Future of EEG-Based BCI Applications
Värbu, K., Muhammad, N., & Muhammad, Y. (2022) · Sensors · doi:10.3390/s22093331 · Cited by 321
Karoly, P. J., Rao, V. R., Gregg, N. M., Worrell, G. A., Bernard, C., Cook, M. J., & Baud, M. O. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-021-00464-1 · Cited by 262
Wireless EEG: A survey of systems and studies
Niso, G., Romero, E., Moreau, J. T., Araujo, A., & Krol, L. R. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2022.119774 · Cited by 244
Electroencephalography (EEG) Technology Applications and Available Devices
Soufineyestani, M., Dowling, D., & Khan, A. (2020) · Applied Sciences · doi:10.3390/app10217453 · Cited by 230
“Conductive solid gel materials, such as those produced by Enobio, have also been used successfully in EEG devices.”
BackgroundMethod
Metadata
- Authors
- Hinrichs, H., Scholz, M., Baum, A. K., Kam, J. W. Y., Knight, R. T., & Heinze, H.-J.
- Venue
- Scientific Reports
- Published
- 2020-03-23
- Volume
- 10
- Issue
- 1
- Pages
- 5218-5218
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3012589689
- Cited by
- 219
- References
- 51
- FWCI
- 13.65
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.