CoChat

Performance of a convolutional neural network derived from an ECG database in recognizing myocardial infarction

Open access
Makimoto, Hisaki, Höckmann, Moritz, Lin, Tina, Glöckner, David, Gerguri, Shqipe, Clasen, Lukas, Schmidt, Jan, Assadi-Schmidt, Athena, Bejinariu, Alexandru, Müller, Patrick, Angendohr, Stephan, Babady, Mehran, Brinkmeyer, Christoph, Makimoto, Asuka, Kelm, Malte · 2020 · Scientific Reports
Cited by 108

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Artificial intelligence (AI) is developing rapidly in the medical technology field, particularly in image analysis. ECG-diagnosis is an image analysis in the sense that cardiologists assess the waveforms presented in a 2-dimensional image. We hypothesized that an AI using a convolutional neural network (CNN) may also recognize ECG images and patterns accurately. We used the PTB ECG database consisting of 289 ECGs including 148 myocardial infarction (MI) cases to develop a CNN to recognize MI in ECG. Our CNN model, equipped with 6-layer architecture, was trained with training-set ECGs. After that, our CNN and 10 physicians are tested with test-set ECGs and compared their MI recognition capability in metrics F1 (harmonic mean of precision and recall) and accuracy. The F1 and accuracy by our CNN were significantly higher (83 ± 4%, 81 ± 4%) as compared to physicians (70 ± 7%, 67 ± 7%, P < 0.0001, respectively). Furthermore, elimination of Goldberger-leads or ECG image compression up to quarter resolution did not significantly decrease the recognition capability. Deep learning with a simple CNN for image analysis may achieve a comparable capability to physicians in recognizing MI on ECG. Further investigation is warranted for the use of AI in ECG image assessment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-020-65105-x

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 108

Metadata

Authors
Makimoto, H., Höckmann, M., Lin, T., Glöckner, D., Gerguri, S., Clasen, L., Schmidt, J., Assadi-Schmidt, A., Bejinariu, A., Müller, P., Angendohr, S., Babady, M., Brinkmeyer, C., Makimoto, A., & Kelm, M.
Venue
Scientific Reports
Published
2020-05-21
Volume
10
Issue
1
Pages
8445-8445
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3028005831
Cited by
108
References
6
FWCI
7.82
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of a convolutional neural network derived from an ECG database in recognizing myocardial infarction. https://app.cochat.ai/papers/10.1038/s41598-020-65105-x
The paper
Makimoto, H., Höckmann, M., Lin, T., Glöckner, D., Gerguri, S., Clasen, L., Schmidt, J., Assadi-Schmidt, A., Bejinariu, A., Müller, P., Angendohr, S., Babady, M., Brinkmeyer, C., Makimoto, A., & Kelm, M. (2020). Performance of a convolutional neural network derived from an ECG database in recognizing myocardial infarction. Scientific Reports. https://doi.org/10.1038/s41598-020-65105-x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.