Performance comparison of modified ComBat for harmonization of radiomic features for multicenter studies
Open accessThe DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Multicenter studies are needed to demonstrate the clinical potential value of radiomics as a prognostic tool. However, variability in scanner models, acquisition protocols and reconstruction settings are unavoidable and radiomic features are notoriously sensitive to these factors, which hinders pooling them in a statistical analysis. A statistical harmonization method called ComBat was developed to deal with the “batch effect” in gene expression microarray data and was used in radiomics studies to deal with the “center-effect”. Our goal was to evaluate modifications in ComBat allowing for more flexibility in choosing a reference and improving robustness of the estimation. Two modified ComBat versions were evaluated: M-ComBat allows to transform all features distributions to a chosen reference, instead of the overall mean, providing more flexibility. B-ComBat adds bootstrap and Monte Carlo for improved robustness in the estimation. BM-ComBat combines both modifications. The four versions were compared regarding their ability to harmonize features in a multicenter context in two different clinical datasets. The first contains 119 locally advanced cervical cancer patients from 3 centers, with magnetic resonance imaging and positron emission tomography imaging. In that case ComBat was applied with 3 labels corresponding to each center. The second one contains 98 locally advanced laryngeal cancer patients from 5 centers with contrast-enhanced computed tomography. In that specific case, because imaging settings were highly heterogeneous even within each of the five centers, unsupervised clustering was used to determine two labels for applying ComBat. The impact of each harmonization was evaluated through three different machine learning pipelines for the modelling step in predicting the clinical outcomes, across two performance metrics (balanced accuracy and Matthews correlation coefficient). Before harmonization, almost all radiomic features had significantly different distributions between labels. These differences were successfully removed with all ComBat versions. The predictive ability of the radiomic models was always improved with harmonization and the improved ComBat provided the best results. This was observed consistently in both datasets, through all machine learning pipelines and performance metrics. The proposed modifications allow for more flexibility and robustness in the estimation. They also slightly but consistently improve the predictive power of resulting radiomic models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
Data Mining: Practical Machine Learning Tools and Techniques
(2011) · Elsevier eBooks · doi:10.1016/c2009-0-19715-5 · Cited by 25,437
Silhouettes: A graphical aid to the interpretation and validation of cluster analysis
Rousseeuw, P. J. (1987) · Journal of Computational and Applied Mathematics · doi:10.1016/0377-0427(87)90125-7 · Cited by 21,392
Adjusting batch effects in microarray expression data using empirical Bayes methods
Johnson, W. E., Li, C., & Rabinovic, A. (2007) · Biostatistics · doi:10.1093/biostatistics/kxj037 · Cited by 8,658
Radiomics: Images Are More than Pictures, They Are Data
Gillies, R. J., Kinahan, P. E., & Hricak, H. (2016) · Radiology · doi:10.1148/radiol.2015151169 · Cited by 8,421
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Radiomics: the bridge between medical imaging and personalized medicine
Lambin, P., Leijenaar, R. T. H., Deist, T. M., Peerlings, J., de Jong, E. E. C., van Timmeren, J., Sanduleanu, S., Larue, R. T. H. M., Even, A. J. G., Jochems, A., et al. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.141 · Cited by 5,688
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Self-citationFDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0
Boellaard, R., Delgado-Bolton, R., Oyen, W. J. G., Giammarile, F., Tatsch, K., Eschner, W., Verzijlbergen, F. J., Barrington, S. F., Pike, L. C., Weber, W. A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-014-2961-x · Cited by 3,303
Bias in error estimation when using cross-validation for model selection
Varma, S., & Simon, R. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-91 · Cited by 2,485
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
Ten quick tips for machine learning in computational biology
Chicco, D. (2017) · BioData Mining · doi:10.1186/s13040-017-0155-3 · Cited by 878
Nordhausen, K. (2009) · International Statistical Review · doi:10.1111/j.1751-5823.2009.00095_18.x · Cited by 637
Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels
Shafiq‐ul‐Hassan, M., Zhang, G. G., Latifi, K., Ullah, G., Hunt, D. C., Balagurunathan, Y., Abdalah, M. A., Schabath, M. B., Goldgof, D. G., Mackin, D., et al. (2017) · Medical Physics · doi:10.1002/mp.12123 · Cited by 585
Chen, C., Grennan, K., Badner, J., Zhang, D., Gershon, E., Jin, L., & Liu, C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0017238 · Cited by 542
Hastie, T., Tibshirani, R., & Friedman, J. (2009) · Springer Series in Statistics · doi:10.1007/978-0-387-84858-7_14 · Cited by 477
Pieper, S., Halle, M., & Kikinis, R. (2005) · 2004 2nd IEEE International Symposium on Biomedical Imaging: Macro to Nano (IEEE Cat No. 04EX821) · doi:10.1109/isbi.2004.1398617 · Cited by 444
Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics
Orlhac, F., Frouin, F., Nioche, C., Ayache, N., & Buvat, I. (2019) · Radiology · doi:10.1148/radiol.2019182023 · Cited by 411
A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET
Orlhac, F., Boughdad, S., Philippe, C., Stalla-Bourdillon, H., Nioche, C., Champion, L., Soussan, M., Frouin, F., Frouin, V., & Buvat, I. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.199935 · Cited by 393
Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
Galavis, P. E., Hollensen, C., Jallow, N., Paliwal, B., & Jeraj, R. (2010) · Acta Oncologica · doi:10.3109/0284186x.2010.498437 · Cited by 344
Luo, J., Schumacher, M., Scherer, A., Sanoudou, D., Megherbi, D., Davison, T., Shi, T., Tong, W., Shi, L., Hong, H., et al. (2010) · The Pharmacogenomics Journal · doi:10.1038/tpj.2010.57 · Cited by 331
Deist, T. M., Dankers, F. J. W. M., Valdes, G., Wijsman, R., Hsu, I., Oberije, C., Lustberg, T., van Soest, J., Hoebers, F., Jochems, A., et al. (2018) · Medical Physics · doi:10.1002/mp.12967 · Cited by 304
Choe, J., Lee, S. M., Do, K.-H., Lee, G., Lee, J.-G., Lee, S. M., & Seo, J. B. (2019) · Radiology · doi:10.1148/radiol.2019181960 · Cited by 296
Peerlings, J., Woodruff, H. C., Winfield, J. M., Ibrahim, A., Van Beers, B. E., Heerschap, A., Jackson, A., Wildberger, J. E., Mottaghy, F. M., DeSouza, N. M., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-41344-5 · Cited by 266
Lucia, F., Visvikis, D., Desseroit, M.-C., Miranda, O., Malhaire, J.-P., Robin, P., Pradier, O., Hatt, M., & Schick, U. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3898-7 · Cited by 245
Self-citationImpact of Image Reconstruction Settings on Texture Features in 18F-FDG PET
Yan, J., Chu-Shern, J. L., Loi, H. Y., Khor, L. K., Sinha, A. K., Quek, S. T., Tham, I. W. K., & Townsend, D. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.156927 · Cited by 242
Voxel size and gray level normalization of CT radiomic features in lung cancer
Shafiq-ul-Hassan, M., Latifi, K., Zhang, G., Ullah, G., Gillies, R., & Moros, E. (2018) · Scientific Reports · doi:10.1038/s41598-018-28895-9 · Cited by 215
Lal, T. N., Chapelle, O., Weston, J., & Elisseeff, A. (2008) · Studies in Fuzziness and Soft Computing · doi:10.1007/978-3-540-35488-8_6 · Cited by 209
Lucia, F., Visvikis, D., Vallières, M., Desseroit, M.-C., Miranda, O., Robin, P., Bonaffini, P. A., Alfieri, J., Masson, I., Mervoyer, A., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4231-9 · Cited by 178
Self-citationDissaux, G., Visvikis, D., Da-ano, R., Pradier, O., Chajon, E., Barillot, I., Duvergé, L., Masson, I., Abgral, R., Santiago Ribeiro, M.-J., et al. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.119.228106 · Cited by 172
Self-citationFeasibility of state of the art PET/CT systems performance harmonisation
Kaalep, A., Sera, T., Rijnsdorp, S., Yaqub, M., Talsma, A., Lodge, M. A., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3977-4 · Cited by 160
Li, Z.-C., Bai, H., Sun, Q., Li, Q., Liu, L., Zou, Y., Chen, Y., Liang, C., & Zheng, H. (2018) · European Radiology · doi:10.1007/s00330-017-5302-1 · Cited by 158
Müller, C., Schillert, A., Röthemeier, C., Trégouët, D.-A., Proust, C., Binder, H., Pfeiffer, N., Beutel, M., Lackner, K. J., Schnabel, R. B., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0156594 · Cited by 150
Sun, C., Tian, X., Liu, Z., Li, W., Li, P., Chen, J., Zhang, W., Fang, Z., Du, P., Duan, H., et al. (2019) · EBioMedicine · doi:10.1016/j.ebiom.2019.07.049 · Cited by 117
Removing batch effects from purified plasma cell gene expression microarrays with modified ComBat
Stein, C. K., Qu, P., Epstein, J., Buros, A., Rosenthal, A., Crowley, J., Morgan, G., & Barlogie, B. (2015) · BMC Bioinformatics · doi:10.1186/s12859-015-0478-3 · Cited by 98
Methods of Hierarchical Clustering
Murtagh, F. D., & Contreras, P. (2011) · arXiv (Cornell University) · doi:10.48550/arxiv.1105.0121 · Cited by 95
Kupfer, P., Guthke, R., Pohlers, D., Huber, R., Koczan, D., & Kinne, R. W. (2012) · BMC Medical Genomics · doi:10.1186/1755-8794-5-23 · Cited by 72
Chatterjee, A., Vallières, M., Dohan, A. J. J., Levesque, I. R., Ueno, Y. R., Saif, S., Reinhold, C., & Seuntjens, J. P. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2019.2893860 · Cited by 58
Self-citationWhy validation of prognostic models matters?
Zwanenburg, A., & Löck, S. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2018.03.004 · Cited by 51
Konstantinopoulos, P. A., Cannistra, S. A., Fountzilas, H., Culhane, A. C., Pillay, K., Rueda, B. R., Cramer, D. W., Seiden, M. V., Birrer, M. J., Coukos, G., et al. (2011) · PLoS ONE · doi:10.1371/journal.pone.0018202 · Cited by 33
Upadhaya, T., Vallières, M., Chatterjee, A., Lucia, F., Bonaffini, P. A., Masson, I., Mervoyer, A., Reinhold, C., Schick, U., Seuntjens, J. P., et al. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2878934 · Cited by 26
Self-citationCaveolin 1 Promotes Renal Water and Salt Reabsorption
Willière, Y., Borschewski, A., Patzak, A. R., Nikitina, T., Dittmayer, C., Daigeler, A. L., Schuelke, M., Bachmann, S., & Mutig, K. (2018) · Scientific Reports · doi:10.1038/s41598-017-19071-6 · Cited by 26
Standardization of Multicentric Image Datasets with Generative Adversarial Networks
Hognon, C., Tixier, F., Gallinato, O., Colin, T., Visvikis, D., & Jaouen, V. (2019) · HAL · Cited by 16
Self-citation
Cited by
A Guide to ComBat Harmonization of Imaging Biomarkers in Multicenter Studies
Orlhac, F., Eertink, J. J., Cottereau, A.-S., Zijlstra, J. M., Thieblemont, C., Meignan, M., Boellaard, R., & Buvat, I. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262464 · Cited by 348
A review in radiomics: Making personalized medicine a reality via routine imaging
Guiot, J., Vaidyanathan, A., Deprez, L., Zerka, F., Danthine, D., Frix, A., Lambin, P., Bottari, F., Tsoutzidis, N., Miraglio, B., et al. (2022) · Medicinal Research Reviews · doi:10.1002/med.21846 · Cited by 337
Papadimitroulas, P., Brocki, L., Christopher Chung, N., Marchadour, W., Vermet, F., Gaubert, L., Eleftheriadis, V., Plachouris, D., Visvikis, D., Kagadis, G. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.009 · Cited by 226
“In case of very high heterogeneity where the number of labels to use with ComBat would be too high with respect to the number of patients, unsupervised clustering can be relied upon to identify potential labels to use for harmonization [168].”
BackgroundMethodSelf-citationMali, S. A., Ibrahim, A., Woodruff, H. C., Andrearczyk, V., Müller, H., Primakov, S., Salahuddin, Z., Chatterjee, A., & Lambin, P. (2021) · Journal of Personalized Medicine · doi:10.3390/jpm11090842 · Cited by 207
Deep Learning With Radiomics for Disease Diagnosis and Treatment: Challenges and Potential
Zhang, X., Zhang, Y., Zhang, G., Qiu, X., Tan, W., Yin, X., & Liao, L. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.773840 · Cited by 181
“(57) proposed a hybrid version based on a modified B-ComBat and MComBat, namely BM-ComBat, to improve the robustness (B) and flexibility (M) of the estimation.”
Background
Metadata
- Authors
- Da-ano, R., Masson, I., Lucia, F., Doré, M., Robin, P., Alfieri, J., Rousseau, C., Mervoyer, A., Reinhold, C., Castelli, J., De Crevoisier, R., Rameé, J. F., Pradier, O., Schick, U., Visvikis, D., & Hatt, M.
- Venue
- Scientific Reports
- Published
- 2020-06-24
- Volume
- 10
- Issue
- 1
- Pages
- 10248-10248
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3038062368
- Cited by
- 204
- References
- 45
- FWCI
- 14.34
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.