Automatic detection of non-perfusion areas in diabetic macular edema from fundus fluorescein angiography for decision making using deep learning
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Vision loss caused by diabetic macular edema (DME) can be prevented by early detection and laser photocoagulation. As there is no comprehensive detection technique to recognize NPA, we proposed an automatic detection method of NPA on fundus fluorescein angiography (FFA) in DME. The study included 3,014 FFA images of 221 patients with DME. We use 3 convolutional neural networks (CNNs), including DenseNet, ResNet50, and VGG16, to identify non-perfusion regions (NP), microaneurysms, and leakages in FFA images. The NPA was segmented using attention U-net. To validate its performance, we applied our detection algorithm on 249 FFA images in which the NPA areas were manually delineated by 3 ophthalmologists. For DR lesion classification, area under the curve is 0.8855 for NP regions, 0.9782 for microaneurysms, and 0.9765 for leakage classifier. The average precision of NP region overlap ratio is 0.643. NP regions of DME in FFA images are identified based a new automated deep learning algorithm. This study is an in-depth study from computer-aided diagnosis to treatment, and will be the theoretical basis for the application of intelligent guided laser.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global prevalence and major risk factors of diabetic retinopathy
Yau, J. W. Y., Rogers, S. L., Kawasaki, R., Lamoureux, E. L., Kowalski, J. W., Bek, T., Chen, S.-J., Dekker, J. M., Fletcher, A., Grauslund, J., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1909 · Cited by 4,985
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Elman, M. J., Ayala, A., Bressler, N. M., Browning, D., Flaxel, C. J., Glassman, A. R., Jampol, L. M., & Stone, T. W. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2014.08.047 · Cited by 562
Comparison of Deep Learning Approaches for Multi-Label Chest X-Ray Classification
Baltruschat, I. M., Nickisch, H., Grass, M., Knopp, T., & Saalbach, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-42294-8 · Cited by 455
Research works printed but not linked: 20
- Tufail, A. et al. Automated diabetic retinopathy image assessment software: diagnostic accuracy and cost-effectiveness compared with human graders. Ophthalmology 124, 343–351. https://doi.org/10.1016/j.ophtha.2016.11.014 (2017). · DOI · Paper page
- Early Treatment Diabetic Retinopathy Study Research Group. Early photocoagulation for diabetic retinopathy: ETDRS report number 9. Ophthalmology 98, 766–785 (1991). · DOI · Paper page
- Elman, M. J. et al. Expanded 2-year follow-up of ranibizumab plus prompt or deferred laser or triamcinolone plus prompt laser for diabetic macular edema. Ophthalmology 118, 609–614. https://doi.org/10.1016/j.ophtha.2010.12.033 (2011). · DOI · Paper page
- Silva, P. S. et al. Diabetic retinopathy severity and peripheral lesions are associated with nonperfusion on ultrawide field angiography. Ophthalmology 122, 2465–2472. https://doi.org/10.1016/j.ophtha.2015.07.034 (2015). · DOI · Paper page
- Zheng, Y. et al. Automated segmentation of foveal avascular zone in fundus fluorescein angiography. Invest. Ophthalmol. Vis. Sci. 51, 3653–3659. https://doi.org/10.1167/iovs.09-4935 (2010). · doi:10.1167/iovs.09-4935
- Lam, C., Yu, C., Huang, L. & Rubin, D. Retinal lesion detection with deep learning using image patches. Invest. Ophthalmol. Vis. Sci. 59, 590–596. https://doi.org/10.1167/iovs.17-22721 (2018). · DOI · Paper page
- Rasta, S. H., Nikfarjam, S. & Javadzadeh, A. Detection of retinal capillary nonperfusion in fundus fluorescein angiogram of diabetic retinopathy. BioImpacts BI 5, 183–190. https://doi.org/10.15171/bi.2015.27 (2015). · doi:10.15171/bi.2015.27
- Zhang, X. H., Chutatape, O. & IEEE. In: ICIP: 2004 International Conference on Image Processing, Volumes 1–5 IEEE International Conference on Image Processing (ICIP) 139–142 (2004).
- Zheng, Y., Kwong, M. T., Maccormick, I. J., Beare, N. A. & Harding, S. P. A comprehensive texture segmentation framework for segmentation of capillary non-perfusion regions in fundus fluorescein angiograms. PLoS ONE 9, e93624. https://doi.org/10.1371/journal.pone.0093624 (2014). · doi:10.1371/journal.pone.0093624
- Zhou, M., Jin, K., Wang, S., Ye, J. & Qian, D. Color retinal image enhancement based on luminosity and contrast adjustment. IEEE Trans. Bio Med. Eng. 65, 521–527. https://doi.org/10.1109/tbme.2017.2700627 (2018). · DOI · Paper page
- Mercan, C. et al. Multi-instance multi-label learning for multi-class classification of whole slide breast histopathology images. IEEE Trans. Med. Imaging 37, 316–325. https://doi.org/10.1109/tmi.2017.2758580 (2018). · DOI · Paper page
- Cao, W., Czarnek, N., Shan, J. & Li, L. Microaneurysm detection using principal component analysis and machine learning methods. IEEE Trans. Nanobiosci. 17, 191–198. https://doi.org/10.1109/tnb.2018.2840084 (2018). · DOI
- Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. & Abramoff, M. D. Automatic detection of red lesions in digital color fundus photographs. IEEE Trans. Med. Imaging 24, 584–592. https://doi.org/10.1109/tmi.2005.843738 (2005). · DOI · Paper page
- Niemeijer, M., van Ginneken, B., Russell, S. R., Suttorp-Schulten, M. S. & Abramoff, M. D. Automated detection and differentiation of drusen, exudates, and cotton-wool spots in digital color fundus photographs for diabetic retinopathy diagnosis. Invest. Ophthalmol. Vis. Sci. 48, 2260–2267. https://doi.org/10.1167/iovs.06-0996 (2007). · DOI · Paper page
- Sanchez, C. I. et al. A novel automatic image processing algorithm for detection of hard exudates based on retinal image analysis. Med. Eng. Phys. 30, 350–357. https://doi.org/10.1016/j.medengphy.2007.04.010 (2008). · DOI
- Abdelmoula, W. M., Shah, S. M. & Fahmy, A. S. Segmentation of choroidal neovascularization in fundus fluorescein angiograms. IEEE Trans. Bio Med. Eng. 60, 1439–1445. https://doi.org/10.1109/tbme.2013.2237906 (2013). · doi:10.1109/tbme.2013.2237906
- Zheng, R. et al. Detection of exudates in fundus photographs with imbalanced learning using conditional generative adversarial network. Biomed. Opt. Express 9, 4863–4878. https://doi.org/10.1364/boe.9.004863 (2018). · DOI
- Bamroongsuk, P., Yi, Q., Harper, C. A. & McCarty, D. Delivery of photocoagulation treatment for diabetic retinopathy at a large Australian ophthalmic hospital: comparisons with national clinical practice guidelines. Clin. Exp. Ophthalmol. 30, 115–119 (2002). · DOI
- Kozak, I. et al. Clinical evaluation and treatment accuracy in diabetic macular edema using navigated laser photocoagulator NAVILAS. Ophthalmology 118, 1119–1124. https://doi.org/10.1016/j.ophtha.2010.10.007 (2011). · DOI
- Payne, J. F. et al. Randomized trial of treat and extend ranibizumab with and without navigated laser versus monthly dosing for DME: TREX-DME 2 year outcomes. Am. J. Ophthalmol. https://doi.org/10.1016/j.ajo.2019.02.005 (2019). · DOI
Cited by
Gao, Z., Pan, X., Shao, J., Jiang, X., Su, Z., Jin, K., & Ye, J. (2023) · British Journal of Ophthalmology · doi:10.1136/bjo-2022-321472 · Cited by 93
Self-citationFFA-GPT: an automated pipeline for fundus fluorescein angiography interpretation and question-answer
Chen, X., Zhang, W., Xu, P., Zhao, Z., Zheng, Y., Shi, D., & He, M. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01101-z · Cited by 72
Liu, X., Wu, J., Shao, A., Shen, W., Ye, P., Wang, Y., Ye, J., Jin, K., & Yang, J. (2024) · Journal of Medical Internet Research · doi:10.2196/51926 · Cited by 52
Self-citationYu, T., Shao, A., Wu, H., Su, Z., Shen, W., Zhou, J., Lin, X., Shi, D., Grzybowski, A., Wu, J., et al. (2025) · Ophthalmology and Therapy · doi:10.1007/s40123-025-01109-y · Cited by 23
“For example, the detection and segmentation of non-perfusion areas (NPA) in DME were a key focus of Jin et al. [18], who utilized deep learning models to compare performance with human experts.”
Self-citationShao, A., Liu, X., Shen, W., Li, Y., Wu, H., Pan, X., Yang, Z., Xu, Y., Zhu, T., Wang, Y., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01759-z · Cited by 16
Self-citation
Metadata
- Authors
- Jin, K., Pan, X., You, K., Wu, J., Liu, Z., Cao, J., Lou, L., Xu, Y., Su, Z., Yao, K., & Ye, J.
- Venue
- Scientific Reports
- Published
- 2020-09-15
- Volume
- 10
- Issue
- 1
- Pages
- 15138-15138
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3087702805
- Cited by
- 59
- References
- 5
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- Zhejiang Provincial Key Research and Development Plan (2019C03020)
- National Key Research and Development Program of China (2019YFC0118401)
- Natural Science Foundation of China (81670888)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic detection of non-perfusion areas in diabetic macular edema from fundus fluorescein angiography for decision making using deep learning. https://app.cochat.ai/papers/10.1038/s41598-020-71622-6
- The paper
- Jin, K., Pan, X., You, K., Wu, J., Liu, Z., Cao, J., Lou, L., Xu, Y., Su, Z., Yao, K., & Ye, J. (2020). Automatic detection of non-perfusion areas in diabetic macular edema from fundus fluorescein angiography for decision making using deep learning. Scientific Reports. https://doi.org/10.1038/s41598-020-71622-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.