Sleep classification from wrist-worn accelerometer data using random forests
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Accurate and low-cost sleep measurement tools are needed in both clinical and epidemiological research. To this end, wearable accelerometers are widely used as they are both low in price and provide reasonably accurate estimates of movement. Techniques to classify sleep from the high-resolution accelerometer data primarily rely on heuristic algorithms. In this paper, we explore the potential of detecting sleep using Random forests. Models were trained using data from three different studies where 134 adult participants (70 with sleep disorder and 64 good healthy sleepers) wore an accelerometer on their wrist during a one-night polysomnography recording in the clinic. The Random forests were able to distinguish sleep-wake states with an F1 score of 73.93% on a previously unseen test set of 24 participants. Detecting when the accelerometer is not worn was also successful using machine learning ($$\hbox {F1-score} > 93.31\%$$ F1-score > 93.31 % ), and when combined with our sleep detection models on day-time data provide a sleep estimate that is correlated with self-reported habitual nap behaviour ($$\hbox {r}=.60$$ r = . 60 ). These Random forest models have been made open-source to aid further research. In line with literature, sleep stage classification turned out to be difficult using only accelerometer data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Weighted kappa: nominal scale agreement provision for scaled disagreement or partial credit
Cohen, J. (1968) · Psychological Bulletin · doi:10.1037/h0026256 · Cited by 8,736
Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250
Migueles, J. H., Rowlands, A. V., Huber, F., Sabia, S., & van Hees, V. T. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0063 · Cited by 955
Self-citationA novel, open access method to assess sleep duration using a wrist-worn accelerometer
van Hees, V. T., Sabia, S., Anderson, K. N., Denton, S. J., Oliver, J., Catt, M., Abell, J. G., Kivimäki, M., Trenell, M. I., & Singh-Manoux, A. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142533 · Cited by 744
Self-citationSabia, S., van Hees, V. T., Shipley, M. J., Trenell, M. I., Hagger-Johnson, G., Elbaz, A., Kivimaki, M., & Singh-Manoux, A. (2014) · American Journal of Epidemiology · doi:10.1093/aje/kwt330 · Cited by 304
Self-citationGenetic studies of accelerometer-based sleep measures yield new insights into human sleep behaviour
Jones, S. E., van Hees, V. T., Mazzotti, D. R., Marques-Vidal, P., Sabia, S., van der Spek, A., Dashti, H. S., Engmann, J., Kocevska, D., Tyrrell, J., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09576-1 · Cited by 300
Self-citationWilletts, M., Hollowell, S., Aslett, L., Holmes, C., & Doherty, A. (2018) · Scientific Reports · doi:10.1038/s41598-018-26174-1 · Cited by 250
Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?
ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001435 · Cited by 187
Cited by
Metrics of sleep apnea severity: beyond the apnea-hypopnea index
Malhotra, A., Ayappa, I., Ayas, N., Collop, N., Kirsch, D., Mcardle, N., Mehra, R., Pack, A. I., Punjabi, N., White, D. P., et al. (2021) · SLEEP · doi:10.1093/sleep/zsab030 · Cited by 489
Machine Learning for Healthcare Wearable Devices: The Big Picture
Sabry, F., Eltaras, T., Labda, W., Alzoubi, K., & Malluhi, Q. (2022) · Journal of Healthcare Engineering · doi:10.1155/2022/4653923 · Cited by 321
AI-Assisted Detection of Biomarkers by Sensors and Biosensors for Early Diagnosis and Monitoring
Wasilewski, T., Kamysz, W., & Gębicki, J. (2024) · Biosensors · doi:10.3390/bios14070356 · Cited by 290
40 years of actigraphy in sleep medicine and current state of the art algorithms
Patterson, M. R., Nunes, A. A. S., Gerstel, D., Pilkar, R., Guthrie, T., Neishabouri, A., & Guo, C. C. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00802-1 · Cited by 91
“Second, accuracy, sensitivity and other statistics were calculated for each subject and then averaged in the current work, whereas Sundararajan et al. 2021 combined all epochs from all subjects together and calculated the evaluation metrics.”
BackgroundMethodInfluentialYuan, H., Plekhanova, T., Walmsley, R., Reynolds, A. C., Maddison, K. J., Bucan, M., Gehrman, P., Rowlands, A., Ray, D. W., Bennett, D., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01065-0 · Cited by 40
Self-citation
Metadata
- Authors
- Sundararajan, K., Georgievska, S., te Lindert, B. H. W., Gehrman, P. R., Ramautar, J., Mazzotti, D. R., Sabia, S., Weedon, M. N., van Someren, E. J. W., Ridder, L., Wang, J., & van Hees, V. T.
- Venue
- Scientific Reports
- Published
- 2021-01-08
- Volume
- 11
- Issue
- 1
- Pages
- 24-24
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3151219741
- Cited by
- 106
- References
- 9
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sleep classification from wrist-worn accelerometer data using random forests. https://app.cochat.ai/papers/10.1038/s41598-020-79217-x
- The paper
- Sundararajan, K., Georgievska, S., te Lindert, B. H. W., Gehrman, P. R., Ramautar, J., Mazzotti, D. R., Sabia, S., Weedon, M. N., van Someren, E. J. W., Ridder, L., Wang, J., & van Hees, V. T. (2021). Sleep classification from wrist-worn accelerometer data using random forests. Scientific Reports. https://doi.org/10.1038/s41598-020-79217-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.