Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent?
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
PURPOSE: Accelerometers are increasingly being used to assess physical activity in large-scale surveys. Establishing whether key physical activity outcomes can be considered equivalent between three widely used accelerometer brands would be a significant step toward capitalizing on the increasing availability of accelerometry data for epidemiological research. METHODS: Twenty participants wore a GENEActiv, an Axivity AX3, and an ActiGraph GT9X on their nondominant wrist and were observed for 2 h in a simulated living space. Participants undertook a series of seated and upright light/active behaviors at their own pace. All accelerometer data were processed identically using open-source software (GGIR) to generate physical activity outcomes (including average dynamic acceleration (ACC) and time within intensity cut points). Data were analyzed using pairwise 95% equivalence tests (±10% equivalence zone), intraclass correlation coefficients (ICC) and limits of agreement. RESULTS: The GENEActiv and Axivity could be considered equivalent for ACC (ICC = 0.95, 95% confidence interval (CI), 0.87-0.98), but ACC measured by the ActiGraph was approximately 10% lower (GENEActiv/ActiGraph: ICC = 0.86; 95% CI, 0.56-0.95; Axivity/ActiGraph: ICC = 0.82; 95% CI, 0.50-0.94). For time spent within intensity cut points, all three accelerometers could be considered equivalent to each other for more than 85% of outcomes (ICC ≥0.69, lower 95% CI ≥0.36), with the GENEActiv and Axivity equivalent for 100% of outcomes (ICC ≥0.95, lower 95% CI ≥0.86). CONCLUSIONS: GENEActiv and Axivity data processed in GGIR are largely equivalent. If GENEActiv or Axivity is compared with the ActiGraph, time spent within intensity cut points has good agreement. These findings can be used to inform selection of appropriate outcomes if outputs from these accelerometer brands are compared.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This device has demonstrated equivalent output49 to the GENEActiv accelerometer, which has been validated using both standard laboratory and free-living energy expenditure assessment methods50,51.”
From GWAS identifies 14 loci for device-measured physical activity and sleep duration (2018) · cites this paper as [49]
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Letter to the Editor: Standardized use of the terms “sedentary” and “sedentary behaviours”
Networ, S. B. R. (2012) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h2012-024 · Cited by 1,873
Doherty, A., Jackson, D., Hammerla, N., Plötz, T., Olivier, P., Granat, M. H., White, T., van Hees, V. T., Trenell, M. I., Owen, C. G., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169649 · Cited by 1,250
Age Group Comparability of Raw Accelerometer Output from Wrist- and Hip-Worn Monitors
HILDEBRAND, M., VAN HEES, V. T., HANSEN, B. H., & EKELUND, U. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000289 · Cited by 1,043
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926
van Hees, V. T., Fang, Z., Langford, J., Assah, F., Mohammad, A., da Silva, I. C. M., Trenell, M. I., White, T., Wareham, N. J., & Brage, S. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00421.2014 · Cited by 676
Mons, U., Muezzinler, A., Gellert, C., Schottker, B., Abnet, C. C., Bobak, M., de Groot, L., Freedman, N. D., Jansen, E., Kee, F., et al. (2015) · BMJ · doi:10.1136/bmj.h1551 · Cited by 526
Evaluation of raw acceleration sedentary thresholds in children and adults
Hildebrand, M., Hansen, B. H., van Hees, V. T., & Ekelund, U. (2017) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/sms.12795 · Cited by 425 · cited 3×
“The inability to differentiate between postures using magnitude of acceleration alone has been previously reported (14,15) with use of further features from the acceleration signal recommended for classification of posture (e.”
Cited by
Migueles, J. H., Rowlands, A. V., Huber, F., Sabia, S., & van Hees, V. T. (2019) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2018-0063 · Cited by 955
Self-citationEstimating sleep parameters using an accelerometer without sleep diary
van Hees, V. T., Sabia, S., Jones, S. E., Wood, A. R., Anderson, K. N., Kivimäki, M., Frayling, T. M., Pack, A. I., Bucan, M., Trenell, M. I., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-31266-z · Cited by 554
GWAS identifies 14 loci for device-measured physical activity and sleep duration
Doherty, A., Smith-Byrne, K., Ferreira, T., Holmes, M. V., Holmes, C., Pulit, S. L., & Lindgren, C. M. (2018) · Nature Communications · doi:10.1038/s41467-018-07743-4 · Cited by 408
Ancillao, A., Tedesco, S., Barton, J., & O’Flynn, B. (2018) · Sensors · doi:10.3390/s18082564 · Cited by 243
Ramakrishnan, R., Doherty, A., Smith-Byrne, K., Rahimi, K., Bennett, D., Woodward, M., Walmsley, R., & Dwyer, T. (2021) · PLOS Medicine · doi:10.1371/journal.pmed.1003487 · Cited by 183
Metadata
- Authors
- ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L.
- Affiliations
- University of Leicester (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-02
- Volume
- 50
- Issue
- 2
- Pages
- 257-265
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2763127012
- Cited by
- 187
- References
- 34
- Citations by year
- 2026: 16 · 2025: 17 · 2024: 25 · 2023: 15 · 2022: 26 · 2021: 32 · 2020: 27 · 2019: 15 · 2018: 13
- FWCI
- 11.34
- Type
- journal article
- Language
- en
- Open access
- green
- journals.lww.com
- Licence
- other-oa
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Leicester Research Archive (University of Leicester) (acceptedVersion, other-oa)
- Loughborough University Institutional Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Figshare (submittedVersion)
- Loughborough University Research Repository (Loughborough University) (submittedVersion, cc-by-nc-nd)
- Funders
- National Institute for Health and Care Research
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- accelerometer, physical activity measurement, GENEActiv, ActiGraph GT9X, wrist-worn accelerometry, equivalence testing, limits of agreement
- MeSH terms
- Acceleration, Adolescent, Adult, Female, Humans, Male, Software, Exercise, Young Adult, Accelerometry
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent? https://app.cochat.ai/papers/10.1249/mss.0000000000001435
- The paper
- ROWLANDS, A. V., MIRKES, E. M., YATES, T., CLEMES, S., DAVIES, M., KHUNTI, K., & EDWARDSON, C. L. (2018). Accelerometer-assessed Physical Activity in Epidemiology: Are Monitors Equivalent? Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000001435
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.