The natural reduction of threat in selected systems of old buildings containing asbestos
Open accessPublished version of a preprint
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
The aim of this study was to measure changes in asbestos dust concentrations over extended use in old building systems. Buildings from different systems during their service lifetimes and after asbestos removal were tested. Asbestos dust concentrations decreased in all building systems due to air exchange and other phenomena in the absence of new active dust sources. Currently, with proper use of those buildings, average values of dust concentrations did not exceed 300–400 f/m 3 with a downward trend to < 300 f/m 3 . The results of these studies were obtained with a modified optical microscopy technique, verified by SEM and TEM methods. The graphical trends in concentration changes over longer periods illustrate the potency of opposing factors reducing and increasing indoor air pollution. If removal asbestos work was not carried out carefully, single measurements conducted in the short-term and mandated immediately after asbestos removal may not detect hazards that appear over time. Monitoring buildings over longer periods allows detection of significant contamination changes. In many cases, the minimal air contamination undermines the desirability of removing asbestos in old buildings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




![Figure 5 Contamination comparison in rigid (“BISTYP”) and non-rigid structures (“LIPSK”). (a) The reduction of the rate of change in the concentration of asbestos dust over a period of time, after reaching a concentration of < 400 f/m3. This applies to objects operated in the same way for longer periods of time without damaging the ACM. The vertical axis corresponds to dust concentrations on a logarithmic scale. The horizontal axis denotes the time when measurements were taken (weeks) on a linear scale. (b) The same data as in (a). Time of measurements [weeks] on a log scale (on the horizontal axis). The figure shows a steady decline in asbestos concentrations in all cases over an extended period.](https://figures.cochat.ai/paper-figures/d08043aa176448bcb5efc4d4e98b0a95/the-natural-reduction-of-threat-in-selected-systems-of-old-buildings-containing-figure-5.jpg)

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“The measured concentration of fibres varies depending on the activity of new dust emission sources, the time that has passed between their formation and sampling, and the building’s use, ventilation and general condition34,35,38.”
From Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland (2023) · cites this paper as [38]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“The study found that wet methods, such as using water misting, were more effective at reducing airborne asbestos fiber levels than dry methods.”
From A critical review of asbestos concentrations in water and air, according to exposure sources (2023) · cites this paper as [87]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Lotter, J. T., Roberts, B., Henshaw, J. L., & Pierce, J. S. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1183010 · Cited by 4
RetractedExposure to asbestos: past, present and future
Pira, E., Donato, F., Maida, L., & Discalzi, G. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2017.10.126 · Cited by 68
Lange, J., Lange, P. R., Reinhard, T. K., & Thomulka, K. W. (1996) · The Annals of Occupational Hygiene · doi:10.1016/0003-4878(95)00081-x · Cited by 55
Asbestos Exposure During Renovation and Demolition of Asbestos-Cement Clad Buildings
BROWN, S. K. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385075 · Cited by 49
Ambient monitoring of asbestos in selected Italian living areas
Gualtieri, A. F., Mangano, D., Gualtieri, M. L., Ricchi, A., Foresti, E., Lesci, G., Roveri, N., Mariotti, M., & Pecchini, G. (2009) · Journal of Environmental Management · doi:10.1016/j.jenvman.2009.06.007 · Cited by 41
Asbestos release from whole-building demolition of buildings with asbestos-containing material
Perkins, R. A., Hargesheimer, J., & Fourie, W. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701691023 · Cited by 33
Visonà, S. D., Villani, S., Manzoni, F., Chen, Y., Ardissino, G., Russo, F., Moretti, M., Javan, G. T., & Osculati, A. (2018) · Journal of Public Health Research · doi:10.4081/jphr.2018.1519 · Cited by 33
Crump, K. S., & Farrar, D. B. (1989) · Regulatory Toxicology and Pharmacology · doi:10.1016/0273-2300(89)90012-3 · Cited by 30
Measurement of asbestos emissions associated with demolition of abandoned residential dwellings
Neitzel, R. L., Sayler, S. K., Demond, A. H., d'Arcy, H., Garabrant, D. H., & Franzblau, A. (2020) · Science of The Total Environment · doi:10.1016/j.scitotenv.2020.137891 · Cited by 30
Donovan, E. P., Donovan, B. L., Sahmel, J. E., Scott, P. K., & Paustenbach, D. J. (2010) · Critical Reviews in Toxicology · doi:10.3109/10408444.2010.506639 · Cited by 29
Exposure to airborne asbestos in buildings
Lee, R. J., Van Orden, D. R., Corn, M., & Crump, K. S. (1992) · Regulatory Toxicology and Pharmacology · doi:10.1016/0273-2300(92)90024-4 · Cited by 27
Exosomes from asbestos‐exposed cells modulate gene expression in mesothelial cells
Munson, P., Lam, Y., Dragon, J., MacPherson, M., & Shukla, A. (2018) · The FASEB Journal · doi:10.1096/fj.201701291rr · Cited by 27
Kim, Y., Hong, W., & Zhang, Y. (2014) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2014.08.092 · Cited by 25
Airborne concentrations of asbestos in 71 school buildings
Corn, M., Crump, K., Farrar, D. B., Lee, R. J., & McFee, D. R. (1991) · Regulatory Toxicology and Pharmacology · doi:10.1016/0273-2300(91)90044-v · Cited by 25
Abelmann, A., Maskrey, J. R., Lotter, J. T., Chapman, A. M., Nembhard, M. D., Pierce, J. S., Wilmoth, J. M., Lee, R. J., & Paustenbach, D. J. (2017) · Inhalation Toxicology · doi:10.1080/08958378.2017.1418940 · Cited by 20
Burdett, G., & BARD, D. (2006) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mel078 · Cited by 19
Spatio-seasonal variation of airborne asbestos concentration in urban areas of Shiraz, Iran
Fathabadi, M. K. F., Abdolahnejad, A., Teiri, H., & Hajizadeh, Y. (2017) · International Journal of Occupational and Environmental Health · doi:10.1080/10773525.2018.1436016 · Cited by 18
Verma, D. K., & Clark, N. E. (1995) · American Industrial Hygiene Association Journal · doi:10.1080/15428119591016494 · Cited by 17
Zhang, Y., Kim, Y., & Hong, W. (2015) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2015.08.004 · Cited by 17
Preparation and Examination of Proposed Consensus Reference Standards for Fiber-Counting
Harper, M., & Bartolucci, A. (2003) · AIHA Journal · doi:10.1080/15428110308984819 · Cited by 14
Sahmel, J. E., Avens, H. J., Scott, P. K., Unice, K. M., Burns, A., Barlow, C. A., Madl, A. K., Henshaw, J., & Paustenbach, D. J. (2015) · Inhalation Toxicology · doi:10.3109/08958378.2015.1110216 · Cited by 13
RATE OF DECLINE OF ASBESTOS FIBRE CONCENTRATION IN ROOM AIR
Moorcroft, J. S., & Duggan, M. (1984) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/28.4.453 · Cited by 11
Young, J. M., Kelly, T. M., & Vance, L. (2008) · Air Quality Atmosphere & Health · doi:10.1007/s11869-008-0015-x · Cited by 11
Airborne Asbestos Exposures from Warm Air Heating Systems in Schools
Burdett, G. J., Dewberry, K., & Staff, J. (2015) · Annals of Occupational Hygiene · doi:10.1093/annhyg/mev062 · Cited by 10 · cited 1×
“Description of drawing elements: (1) Steel pole, (2) Steel connector, (3) PW3/A or PŻW3/A, sandwich panel with a mineral wool core, faced on both sides with (3)—asbestos cement flat panels, (4) Mineral wool thermal insulation core of PW/3A board, (5) Wall facade made of corrugated sheet steel.”
Background(2007) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mem020 · Cited by 9
Interpretation of Airborne Asbestos Measurements
Chesson, J., Rench, J. D., Schultz, B. D., & Milne, K. L. (1990) · Risk Analysis · doi:10.1111/j.1539-6924.1990.tb00527.x · Cited by 8
Factors Affecting Airborne Concentrations of Asbestos in a Commercial Building
Reynolds, S. J., Kreiger, R. A., Bohn, J. A., Fish, D., Marxhausen, T., & McJilton, C. (1994) · American Industrial Hygiene Association Journal · doi:10.1080/15428119491018547 · Cited by 8
Asbestos release from the demolition of two schools in Fairbanks, Alaska
Wilmoth, R. C., Taylor, M. S., & Taylor, M. S. (1994) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1994.10388343 · Cited by 8
Asbestos: A Silent Potent Killer
Aremu, S. O., & Zephaniah, H. S. (2019) · European Journal of Environment and Public Health · doi:10.29333/ejeph/5906 · Cited by 6
Song, S., Jang, B.-K., Jo, B.-H., Kim, Y.-J., Heo, E.-H., Lee, J.-D., Son, B., & Lee, J. (2016) · Journal of Korean Society of Occupational and Environmental Hygiene · doi:10.15269/jksoeh.2016.26.3.267 · Cited by 4
Besson, P. (1999) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(99)00041-1 · Cited by 3
Jung, J.-S., Park, H.-K., Song, H.-S., Lee, W.-J., Kim, Y., & Jeon, H.-J. (2015) · Journal of the Korea Academia-Industrial cooperation Society · doi:10.5762/kais.2015.16.7.5029 · Cited by 2
Bellassai, D., Spinazzola, A., & Silvestri, S. (2015) · PubMed · Cited by 2
Obmiński, Z., Mroczkowska, H., Borkowski, L., & Supiński, J. (2016) · Polish Journal of Sports Medicine · doi:10.5604/1232406x.1207349 · Cited by 1
Research works printed but not linked: 6
- Kadlewicz, K. Testing of the asbestos fibres concentration in the atmosphere at workstations and in the environment. Res. Rep. Min. Environ. Q. 4, 19–40 (2009) (in Polish).
- Kim, J. Y. et al. A study on the factors affecting asbestos exposure level from asbestos abatement in building. J. Korean Soc. Occup. Environ. Hyg. 19(1), 8–15 (2009).
- Dyczek, J. Asbestos Risk reduction & measurement of asbestos fibre concentration. In Conference September 28–29, Cracow AGH University of Science and Technology Faculty of Materials Science and Ceramics Department of Building Materials (2006) (in Polish).
- Obmiński, A. Problems of the pollution of buildings using asbestos-containing products. In IV Poland-Wide Interdisciplinary Scientific and Technical Conference "Ecology and construction". Bielsko Biała: Polish Association of Construction Engineers and Technicians, 249–272 (1992) (in Polish).
- Obmiński, A. Air pollution with asbestos dust during works to dismantle asbestos-containing products. In VII Silesian Forum of Construction Investments, Real Estate. Katowice, conference 10–11. 06: Silesian Building Forum, spec. Issue 58–61 http://izbabud.pl/wpcontent/uploads/2016/07/Forum_Budownictwa_%C5%9Al%C4%85skiego_2015_01-1.pdf (2015) (in Polish).
- Kropiunik, H. Asbestos air monitoring correlation between results of PCM and SEM measurements. Asbestos Risk reduction & measurement of asbestos fibre concentration (ed. Dyczek, J.) conference: Sep. 28–29, Cracow AGH University of Science and Technology Faculty of Materials Science and Ceramics Department of Building Materials (2006).
Cited by
A critical review of asbestos concentrations in water and air, according to exposure sources
Peña-Castro, M., Montero-Acosta, M., & Saba, M. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e15730 · Cited by 58
“A more recent study evaluated the effectiveness of different dust suppression strategies in reducing occupational exposure to asbestos during asbestos removal work Andrzej Obmiński (2022) [87].”
BackgroundSingh, R., & Frank, A. L. (2023) · Cureus · doi:10.7759/cureus.37305 · Cited by 13
Frangioudakis, G., Collins, J., Otness, P., Goode, J., Tomley, S., Franklin, P., & Ross, J. (2023) · Sustainability · doi:10.3390/su151512071 · Cited by 15
“A 2022 study of changes in asbestos fibre concentrations in typical Eastern European buildings found that indoor airborne fibre concentrations are generally low and reduce over time, with ventilation being an important factor in the reductions [17].”
BackgroundHousehold air pollution and human health
Rybak, J., & Pieśniewska, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-16090-5.00005-2 · Cited by 12
Obmiński, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-70631-z · Cited by 9
Self-citation
Metadata
- Authors
- Obmiński, A.
- Affiliations
- Instytut Techniki Budowlanej (PL)
- Corresponding author
- Obmiński, Andrzej
- ORCID
- Obmiński, Andrzej
- Venue
- Scientific Reports
- Published
- 2022-02-16
- Volume
- 12
- Issue
- 1
- Pages
- 2580-2580
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC8850589
- OpenAlex
- W4225472082
- Cited by
- 7
- References
- 34
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 4
- FWCI
- 0.59
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Research Square (acceptedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- asbestos, indoor air pollution, old buildings, building services, air exchange, asbestos removal, long-term monitoring, indoor air quality
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.