Increased emission intensity can compensate for the presence of noise in human click-based echolocation
Open accessThe DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.
Abstract
Echolocating bats adapt their emissions to succeed in noisy environments. In the present study we investigated if echolocating humans can detect a sound-reflecting surface in the presence of noise and if intensity of echolocation emissions (i.e. clicks) changes in a systematic pattern. We tested people who were blind and had experience in echolocation, as well as blind and sighted people who had no experience in echolocation prior to the study. We used an echo-detection paradigm where participants listened to binaural recordings of echolocation sounds (i.e. they did not make their own click emissions), and where intensity of emissions and echoes changed adaptively based on participant performance (intensity of echoes was yoked to intensity of emissions). We found that emission intensity had to systematically increase to compensate for weaker echoes relative to background noise. In fact, emission intensity increased so that spectral power of echoes exceeded spectral power of noise by 12 dB in 4-kHz and 5-kHz frequency bands. The effects were the same across all participant groups, suggesting that this effect occurs independently of long-time experience with echolocation. Our findings demonstrate for the first time that people can echolocate in the presence of noise and suggest that one potential strategy to deal with noise is to increase emission intensity to maintain signal-to-noise ratio of certain spectral components of the echoes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Consistent with our observation that participants coped with these varied levels of ambient noise, we have also shown in laboratory based work [40] that intensity of click emissions can compensate for the presence of background noise in human echolocation.”
From Human click-based echolocation: Effects of blindness and age, and real-life implications in a 10-week training program (2021) · cites this paper as [40]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brainard, D. H. (1997) · Spatial Vision · doi:10.1163/156856897x00357 · Cited by 19,702
An Introduction to the Psychology of Hearing: Fourth Edition
Moore, B. (1997) · BRILL eBooks · doi:10.1163/9789004658820 · Cited by 2,646
Psychoacoustics: facts and models
(1991) · Choice Reviews Online · doi:10.5860/choice.28-5706 · Cited by 2,402
Introduction to the Psychology of Hearing
OWENS, E. (1977) · Archives of Otolaryngology - Head and Neck Surgery · doi:10.1001/archotol.1977.00780290081022 · Cited by 1,766
Griffin, D. R., & Lindsay, R. B. (1958) · Medical Entomology and Zoology · Cited by 1,450
Litovsky, R. Y., Colburn, H. S., Yost, W. A., & Guzman, S. J. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.427914 · Cited by 756
Au, W. W. L. (1993) · Springer eBooks · doi:10.1007/978-1-4612-4356-4 · Cited by 645
The Precedence Effect in Sound Localization
Wallach, H., Newman, E. B., & Rosenzweig, M. R. (1949) · The American Journal of Psychology · doi:10.2307/1418275 · Cited by 614
Prins, N., & Kingdom, F. A. A. (2018) · Frontiers in Psychology · doi:10.3389/fpsyg.2018.01250 · Cited by 429
The evolution of the Lombard effect: 100 years of psychoacoustic research
Brumm, H., & Zollinger, S. A. (2011) · Behaviour · doi:10.1163/000579511x605759 · Cited by 413
Research works printed but not linked: 2
- Thaler, L. & Castillo-Serrano, J. G. People’s ability to detect objects using click-based echolocation: a direct comparison between mouth-clicks and clicks made by a loudspeaker. PLoS ONE 11(5), e0154868. https://doi.org/10.1371/journal.pone.0154868 (2016). · DOI · Paper page
- Bilsen, F. Repetition pitch: monaural interaction of a sound with the repetition of the same, but phase shifted sound. Acta Acust. united Ac. 17, 295–300 (1966).
Cited by
Norman, L. J., Dodsworth, C., Foresteire, D., & Thaler, L. (2021) · PLOS ONE · doi:10.1371/journal.pone.0252330 · Cited by 59
“Consistent with our observation that participants coped with these varied levels of ambient noise, we have also shown in laboratory based work [40] that intensity of click emissions can compensate for the presence of background noise in human echolocation.”
BackgroundSelf-citationThaler, L. (2022) · Physiology News · doi:10.36866/pn.126.20 · Cited by 2
Self-citationThaler, L., Castillo-Serrano, J., Kish, D., & Norman, L. J. (2024) · Neuropsychologia · doi:10.1016/j.neuropsychologia.2024.108822 · Cited by 2
Self-citationReview of Methodologies in Recent Research of Human Echolocation
Bujacz, M., Sztyler, B., Wileńska, N., Czajkowska, K., & Strumiłło, P. (2023) · Archives of Acoustics · doi:10.24425/aoa.2023.145236 · Cited by 2
Why don’t we have whiskers? What we can learn from mammalian whisker touch sensing
Grant, R. A. (2022) · Physiology News · doi:10.36866/pn.126.24 · Cited by 2
Metadata
- Authors
- Castillo-Serrano, J. G., Norman, L. J., Foresteire, D., & Thaler, L.
- Affiliations
- Durham University (GB)
- Corresponding author
- Thaler, L.
- Venue
- Scientific Reports
- Published
- 2021-01-18
- Volume
- 11
- Issue
- 1
- Pages
- 1750-1750
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC7813859
- OpenAlex
- W3124197991
- Cited by
- 24
- References
- 36
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 1 · 2022: 20 · 2021: 1
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, other-oa)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Durham Research Online (Durham University) (acceptedVersion, other-oa)
- Durham Research Online (Durham University) (acceptedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Consejo Nacional de Ciencia y Tecnología (CONACyT, 600799)
- RCUK | Biotechnology and Biological Sciences Research Council (BB/M007847/1)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Agricultural and Biological Sciences › Ecology, Evolution, Behavior and Systematics › Bat Biology and Ecology Studies
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neuroscience and Music Perception
- Keywords
- human echolocation, emission intensity, background noise, echo detection, signal-to-noise ratio, blind people, auditory spatial perception, spectral power, noise compensation
- MeSH terms
- Adaptation, Physiological, Adult, Aged, Animals, Blindness, Echolocation, Female, Humans, Male, Middle Aged, Noise, Sound, Sound Localization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increased emission intensity can compensate for the presence of noise in human click-based echolocation. https://app.cochat.ai/papers/10.1038/s41598-021-81220-9
- The paper
- Castillo-Serrano, J. G., Norman, L. J., Foresteire, D., & Thaler, L. (2021). Increased emission intensity can compensate for the presence of noise in human click-based echolocation. Scientific Reports. https://doi.org/10.1038/s41598-021-81220-9
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.