CoChat

Increased emission intensity can compensate for the presence of noise in human click-based echolocation

Open access

The DOI matches its Crossref record; 35 of the 36 references it cites were found in a registry or an index.

Abstract

Echolocating bats adapt their emissions to succeed in noisy environments. In the present study we investigated if echolocating humans can detect a sound-reflecting surface in the presence of noise and if intensity of echolocation emissions (i.e. clicks) changes in a systematic pattern. We tested people who were blind and had experience in echolocation, as well as blind and sighted people who had no experience in echolocation prior to the study. We used an echo-detection paradigm where participants listened to binaural recordings of echolocation sounds (i.e. they did not make their own click emissions), and where intensity of emissions and echoes changed adaptively based on participant performance (intensity of echoes was yoked to intensity of emissions). We found that emission intensity had to systematically increase to compensate for weaker echoes relative to background noise. In fact, emission intensity increased so that spectral power of echoes exceeded spectral power of noise by 12 dB in 4-kHz and 5-kHz frequency bands. The effects were the same across all participant groups, suggesting that this effect occurs independently of long-time experience with echolocation. Our findings demonstrate for the first time that people can echolocate in the presence of noise and suggest that one potential strategy to deal with noise is to increase emission intensity to maintain signal-to-noise ratio of certain spectral components of the echoes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-021-81220-9

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Waveform plot (left channel only) of recording of click emission made in front of the speaker. a.u. – arbitray units.
Figure 1 Waveform plot (left channel only) of recording of click emission made in front of the speaker. a.u. – arbitray units.CC BY · PubMed Central
Figure 2 Picture of the manikin used to make binaural recordings. Anthropometric details of this manikin have been published elsewhere12. The center of the speaker used to generate emissions was placed at the mouth of the manikin (marked by a small tube).
Figure 2 Picture of the manikin used to make binaural recordings. Anthropometric details of this manikin have been published elsewhere12. The center of the speaker used to generate emissions was placed at the mouth of the manikin (marked by a small tube).CC BY · PubMed Central
Figure 3 Illustration (top view) of recording setup for the various echolocation sound conditions used in the experiment. Echolocation sounds were recorded in an empty space (object absent; left), in the presence of a 17.5-cm diameter disk at 1-m distance (middle) and in the presence of a 26.5-cm diameter disk that could be placed at 1 m, 2 m, or 3 m (right). In all conditions the disk was placed so that its round, flat side faced the manikin. Here (in the top view) the disk is illustrated as a horizontal line.
Figure 3 Illustration (top view) of recording setup for the various echolocation sound conditions used in the experiment. Echolocation sounds were recorded in an empty space (object absent; left), in the presence of a 17.5-cm diameter disk at 1-m distance (middle) and in the presence of a 26.5-cm diameter disk that could be placed at 1 m, 2 m, or 3 m (right). In all conditions the disk was placed so that its round, flat side faced the manikin. Here (in the top view) the disk is illustrated as a horizontal line.CC BY · PubMed Central
Figure 4 Waveform plots (left channel only) of echolocation sound recordings used during the experiment. From top to bottom: Object Absent, 17.5-cm disk at 1 m, 26.5-cm disk at 1 m, 26.5-cm disk at 2 m, 26.5-cm disk at 3 m. a.u. – arbitray units.
Figure 4 Waveform plots (left channel only) of echolocation sound recordings used during the experiment. From top to bottom: Object Absent, 17.5-cm disk at 1 m, 26.5-cm disk at 1 m, 26.5-cm disk at 2 m, 26.5-cm disk at 3 m. a.u. – arbitray units.CC BY · PubMed Central
Figure 5 Emission SNRs for the different conditions and participant groups (SC – sighted controls; BC – blind controls; EE – expert echolocators). Bars represent means and error bars represent standard error of the mean across participants. Circles represent individual participants.
Figure 5 Emission SNRs for the different conditions and participant groups (SC – sighted controls; BC – blind controls; EE – expert echolocators). Bars represent means and error bars represent standard error of the mean across participants. Circles represent individual participants.CC BY · PubMed Central
Figure 6 Echo SNRs for the different conditions and participant groups (SC – sighted controls; BC – blind controls; EE – expert echolocators). Bars represent means and error bars represent standard error of the mean across participants. Circles represent individual participants.
Figure 6 Echo SNRs for the different conditions and participant groups (SC – sighted controls; BC – blind controls; EE – expert echolocators). Bars represent means and error bars represent standard error of the mean across participants. Circles represent individual participants.CC BY · PubMed Central
Figure 7 Power spectra (1/3 Octave Bands) for noise and clicks (top panel) and noise and echoes (bottom panel). Black lines denote data for noise, and red and blue solid and dashed lines denote data from clicks and echoes in the various conditions.
Figure 7 Power spectra (1/3 Octave Bands) for noise and clicks (top panel) and noise and echoes (bottom panel). Black lines denote data for noise, and red and blue solid and dashed lines denote data from clicks and echoes in the various conditions.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Research works printed but not linked: 2

  1. Thaler, L. & Castillo-Serrano, J. G. People’s ability to detect objects using click-based echolocation: a direct comparison between mouth-clicks and clicks made by a loudspeaker. PLoS ONE 11(5), e0154868. https://doi.org/10.1371/journal.pone.0154868 (2016). · DOI · Paper page
  2. Bilsen, F. Repetition pitch: monaural interaction of a sound with the repetition of the same, but phase shifted sound. Acta Acust. united Ac. 17, 295–300 (1966).

Cited by

See all 24

Metadata

Authors
Castillo-Serrano, J. G., Norman, L. J., Foresteire, D., & Thaler, L.
Affiliations
Durham University (GB)
Corresponding author
Thaler, L.
Venue
Scientific Reports
Published
2021-01-18
Volume
11
Issue
1
Pages
1750-1750
ISSN
2045-2322 (ISSN-L)
OpenAlex
W3124197991
Cited by
24
References
36
Citations by year
2025: 1 · 2024: 1 · 2023: 1 · 2022: 20 · 2021: 1
FWCI
3.02
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Durham Research Online (Durham University) (acceptedVersion, other-oa)
  • Durham Research Online (Durham University) (acceptedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Consejo Nacional de Ciencia y Tecnología (CONACyT, 600799)
  • RCUK | Biotechnology and Biological Sciences Research Council (BB/M007847/1)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
  • Life Sciences › Agricultural and Biological Sciences › Ecology, Evolution, Behavior and Systematics › Bat Biology and Ecology Studies
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Neuroscience and Music Perception
Keywords
human echolocation, emission intensity, background noise, echo detection, signal-to-noise ratio, blind people, auditory spatial perception, spectral power, noise compensation
MeSH terms
Adaptation, Physiological, Adult, Aged, Animals, Blindness, Echolocation, Female, Humans, Male, Middle Aged, Noise, Sound, Sound Localization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Increased emission intensity can compensate for the presence of noise in human click-based echolocation. https://app.cochat.ai/papers/10.1038/s41598-021-81220-9
The paper
Castillo-Serrano, J. G., Norman, L. J., Foresteire, D., & Thaler, L. (2021). Increased emission intensity can compensate for the presence of noise in human click-based echolocation. Scientific Reports. https://doi.org/10.1038/s41598-021-81220-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.