Clinical evaluation of a real-time artificial intelligence-based polyp detection system: a US multi-center pilot study
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Artificial intelligence (AI) has increasingly been employed in multiple fields, and there has been significant interest in its use within gastrointestinal endoscopy. Computer-aided detection (CAD) can potentially improve polyp detection rates and decrease miss rates in colonoscopy. However, few clinical studies have evaluated real-time CAD during colonoscopy. In this study, we analyze the efficacy of a novel real-time CAD system during colonoscopy. This was a single-arm prospective study of patients undergoing colonoscopy with a real-time CAD system. This AI-based system had previously been trained using manually labeled colonoscopy videos to help detect neoplastic polyps (adenomas and serrated polyps). In this pilot study, 300 patients at two centers underwent elective colonoscopy with the CAD system. These results were compared to 300 historical controls consisting of consecutive colonoscopies performed by the participating endoscopists within 12 months prior to onset of the study without the aid of CAD. The primary outcome was the mean number of adenomas per colonoscopy. Use of real-time CAD trended towards increased adenoma detection (1.35 vs 1.07, p = 0.099) per colonoscopy though this did not achieve statistical significance. Compared to historical controls, use of CAD demonstrated a trend towards increased identification of serrated polyps (0.15 vs 0.07) and all neoplastic (adenomatous and serrated) polyps (1.50 vs 1.14) per procedure. There were significantly more non-neoplastic polyps detected with CAD (1.08 vs 0.57, p < 0.0001). There was no difference in ≥ 10 mm polyps identified between the two groups. A real-time CAD system can increase detection of adenomas and serrated polyps during colonoscopy in comparison to historical controls without CAD, though this was not statistically significant. As this pilot study is underpowered, given the findings we recommend pursuing a larger randomized controlled trial to further evaluate the benefits of CAD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artificial intelligence in healthcare: past, present and future
Jiang, F., Jiang, Y., Zhi, H., Dong, Y., Li, H., Ma, S., Wang, Y., Dong, Q., Shen, H., & Wang, Y. (2017) · Stroke and Vascular Neurology · doi:10.1136/svn-2017-000101 · Cited by 4,837
Artificial intelligence in medicine
Hamet, P., & Tremblay, J. (2017) · Metabolism · doi:10.1016/j.metabol.2017.01.011 · Cited by 2,334
Wang, P., Berzin, T. M., Glissen Brown, J. R., Bharadwaj, S., Becq, A., Xiao, X., Liu, P., Li, L., Song, Y., Zhang, D., et al. (2019) · Gut · doi:10.1136/gutjnl-2018-317500 · Cited by 865 · cited 2×
“Wang et al. conducted a prospective randomized controlled study to compare the difference in adenoma detection rate with or without real-time automated CAD 13 .”
BackgroundZhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660 · cited 1×
“In a meta-analysis of tandem colonoscopy studies, the lesion miss rate has been reported to be as high as 26% 3 .”
BackgroundHassan, C., Spadaccini, M., Iannone, A., Maselli, R., Jovani, M., Chandrasekar, V. T., Antonelli, G., Yu, H., Areia, M., Dinis-Ribeiro, M., et al. (2021) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2020.06.059 · Cited by 529 · cited 1×
“Detection of adenomas and serrated polyps are important components of high-quality colonoscopy, and it has been reported that high adenoma detection rates may reduce the risk of interval cancer 14,15 .”
BackgroundFernández-Esparrach, G., Bernal, J., López-Cerón, M., Córdova, H., Sánchez-Montes, C., Rodríguez de Miguel, C., & Sánchez, F. (2016) · Endoscopy · doi:10.1055/s-0042-108434 · Cited by 146
Cited by
Wei, M. T., Fay, S., Yung, D., Ladabaum, U., & Kopylov, U. (2024) · Clinical and Translational Gastroenterology · doi:10.14309/ctg.0000000000000671 · Cited by 57
Self-citationEnhancing human-AI collaboration: The case of colonoscopy
Introzzi, L., Zonca, J., Cabitza, F., Cherubini, P., & Reverberi, C. (2024) · Digestive and Liver Disease · doi:10.1016/j.dld.2023.10.018 · Cited by 28
Berzin, T. M., & Glissen Brown, J. (2023) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000002286 · Cited by 10
Metadata
- Authors
- Quan, S. Y., Wei, M. T., Lee, J., Mohi-Ud-Din, R., Mostaghim, R., Sachdev, R., Siegel, D., Friedlander, Y., & Friedland, S.
- Venue
- Scientific Reports
- Published
- 2022-04-21
- Volume
- 12
- Issue
- 1
- Pages
- 6598-6598
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W4224240826
- Cited by
- 55
- References
- 6
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical evaluation of a real-time artificial intelligence-based polyp detection system: a US multi-center pilot study. https://app.cochat.ai/papers/10.1038/s41598-022-10597-y
- The paper
- Quan, S. Y., Wei, M. T., Lee, J., Mohi-Ud-Din, R., Mostaghim, R., Sachdev, R., Siegel, D., Friedlander, Y., & Friedland, S. (2022). Clinical evaluation of a real-time artificial intelligence-based polyp detection system: a US multi-center pilot study. Scientific Reports. https://doi.org/10.1038/s41598-022-10597-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.