Assessing reliability and validity of different stiffness measurement tools on a multi-layered phantom tissue model
Published version of a preprint
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Changes in the mechanical properties (i.e., stiffness) of soft tissues have been linked to musculoskeletal disorders, pain conditions, and cancer biology, leading to a rising demand for diagnostic methods. Despite the general availability of different stiffness measurement tools, it is unclear as to which are best suited for different tissue types and the related measurement depths. The study aimed to compare different stiffness measurement tools’ (SMT) reliability on a multi-layered phantom tissue model (MPTM). A polyurethane MPTM simulated the four layers of the thoracolumbar region: cutis (CUT), subcutaneous connective tissue (SCT), fascia profunda (FPR), and erector spinae (ERS), with varying stiffness parameters. Evaluated stiffness measurement tools included Shore Durometer, Semi-Electronic Tissue Compliance Meter (STCM), IndentoPRO, MyotonPRO, and ultrasound imaging. Measurements were made by two independent, blinded examiners. Shore Durometer, STCM, IndentoPRO, and MyotonPRO reliably detected stiffness changes in three of the four MPTM layers, but not in the thin (1 mm thick) layer simulating FPR. With ultrasound imaging, only stiffness changes in layers thicker than 3 mm could be measured reliably. Significant correlations ranging from 0.70 to 0.98 (all p < 0.01) were found. The interrater reliability ranged from good to excellent (ICC(2,2) = 0.75–0.98). The results are encouraging for researchers and clinical practitioners as the investigated stiffness measurement tools are easy-to-use and comparatively affordable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Additionally, Bartsch et al. (Bartsch et al., 2023) demonstrated that MyotonPro may not be able to measure thin layers in multilayered structures such as the skin.”
From Multimodal assessment of the skin biomechanical properties during wound healing and hyaluronic acid response (2026) · cites this paper as Bartsch et al., 2023
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Visible Human Male: A Technical Report
Spitzer, V., Ackerman, M. J., Scherzinger, A. L., & Whitlock, D. (1996) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1996.96236280 · Cited by 705
Reduced thoracolumbar fascia shear strain in human chronic low back pain
Langevin, H. M., Fox, J. R., Koptiuch, C., Badger, G. J., Greenan- Naumann, A. C., Bouffard, N. A., Konofagou, E. E., Lee, W.-N., Triano, J. J., & Henry, S. M. (2011) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-12-203 · Cited by 383
Research works printed but not linked: 68
- Wu, A. et al. Global low back pain prevalence and years lived with disability from 1990 to 2017: Estimates from the Global Burden of Disease Study 2017. Ann. Transl. Med. 8, 299 (2020). · DOI · Paper page
- Langevin, H. M. & Sherman, K. J. Pathophysiological model for chronic low back pain integrating connective tissue and nervous system mechanisms. Med. Hypotheses 68, 74–80 (2007). · DOI · Paper page
- Langevin, H. M. et al. Ultrasound evidence of altered lumbar connective tissue structure in human subjects with chronic low back pain. BMC Musculoskelet. Disord. 10, 151 (2009). · DOI · Paper page
- Willard, F. H., Vleeming, A., Schuenke, M. D., Danneels, L. & Schleip, R. The thoracolumbar fascia: Anatomy, function and clinical considerations. J. Anat. 221, 507–536 (2012). · DOI · Paper page
- Brandl, A., Egner, C. & Schleip, R. Immediate effects of myofascial release on the thoracolumbar fascia and osteopathic treatment for acute low back pain on spine shape parameters: A randomized, placebo-controlled trial. Life 11, 845 (2021). · DOI
- Holzapfel, G. Biomechanics of Soft Tissue. in Handbook of Materials Behavior models (ed. Lematre, J.) 1049–1063 (Academic Press, 2001). · DOI · Paper page
- Langevin, H. M. et al. Connecting (t)issues: How research in fascia biology can impact integrative oncology. Cancer Res. 76, 6159–6162 (2016). · DOI
- Alvarez-Diaz, P. et al. Effects of anterior cruciate ligament injury on neuromuscular tensiomyographic characteristics of the lower extremity in competitive male soccer players. Knee Surg. Sport. Traumatol. Arthrosc. 24, 2264–2270 (2016). · DOI
- Sakai, F., Ebihara, S., Akiyama, M. & Horikawa, M. Pericranial muscle hardness in tension-type headache. A non-invasive measurement method and its clinical application. Brain 118(Pt 2), 523–531 (1995). · doi:10.1093/brain/118.2.523
- Kuo, W.-H., Jian, D.-W., Wang, T.-G. & Wang, Y.-C. Neck muscle stiffness quantified by sonoelastography is correlated with body mass index and chronic neck pain symptoms. Ultrasound Med. Biol. 39, 1356–1361 (2013). · DOI
- Tafazzoli, F. & Lamontagne, M. Mechanical behaviour of hamstring muscles in low-back pain patients and control subjects. Clin. Biomech. 11, 16–24 (1996). · DOI
- Li, Y., Yu, J., Zhang, J., Zhang, Z. & Wang, X. Quantifying the stiffness of lumbar erector spinae during different positions among participants with chronic low back pain. PLoS ONE 17, e0270286 (2022). · doi:10.1371/journal.pone.0270286
- Zügel, M. et al. Fascial tissue research in sports medicine: From molecules to tissue adaptation, injury and diagnostics: Consensus statement. Br. J. Sports Med. 52, 1497 (2018). · DOI · Paper page
- Muckelt, P. E. et al. Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue. Sci. Rep. 12, 13654 (2022). · DOI
- Wilke, J., Vogt, L., Pfarr, T. & Banzer, W. Reliability and validity of a semi-electronic tissue compliance meter to assess muscle stiffness. J. Back Musculoskelet. Rehabil. 31, 991–997 (2018). · DOI
- Oflaz, H. & Baran, O. A new medical device to measure a stiffness of soft materials. Acta Bioeng. Biomech. 16, 125–131 (2014).
- Sohirad, S., Wilson, D., Waugh, C., Finnamore, E. & Scott, A. Feasibility of using a hand-held device to characterize tendon tissue biomechanics. PLoS ONE 12, e0184463 (2017). · doi:10.1371/journal.pone.0184463
- Avila Gonzalez, C. A. et al. Frontiers in fascia research. J. Bodyw. Mov. Ther. 22, 873–880 (2018). · DOI
- Moreau, B. et al. Non-invasive assessment of human multifidus muscle stiffness using ultrasound shear wave elastography: A feasibility study. Proc. Inst. Mech. Eng. Part H J. Eng. Med. 230, 809–814 (2016). · doi:10.1177/0954411916656022
- Nair, K. et al. Stiffness of resting lumbar myofascia in healthy young subjects quantified using a handheld myotonometer and concurrently with surface electromyography monitoring. J. Bodyw. Mov. Ther. 20, 388–396 (2016). · DOI
- Lohr, C., Braumann, K.-M., Reer, R., Schroeder, J. & Schmidt, T. Reliability of tensiomyography and myotonometry in detecting mechanical and contractile characteristics of the lumbar erector spinae in healthy volunteers. Eur. J. Appl. Physiol. 118, 1349–1359 (2018). · DOI
- Mix, A. & Giacomin, A. Standardized polymer durometry. J. Test. Eval. 39, 696–705 (2011). · doi:10.1520/jte103205
- Falanga, V. & Bucalo, B. Use of a durometer to assess skin hardness. J. Am. Acad. Dermatol. 29, 47–51 (1993). · DOI · Paper page
- Fischer, A. A. Tissue compliance meter for objective, quantitative documentation of soft tissue consistency and pathology. Arch. Phys. Med. Rehabil. 68, 122–125 (1987).
- Kett, A. R. & Sichting, F. Sedentary behaviour at work increases muscle stiffness of the back: Why roller massage has potential as an active break intervention. Appl. Ergon. 82, 102947 (2020). · DOI
- Koch, V. & Wilke, J. Reliability of a new indentometer device for measuring myofascial tissue stiffness. J. Clin. Med. 11, 5194 (2022). · DOI
- Kett, A. R., Milani, T. L. & Sichting, F. Sitting for too long, moving too little: Regular muscle contractions can reduce muscle stiffness during prolonged periods of chair-sitting. Front. Sport. Act. living 3, 760533 (2021). · DOI
- Chuang, L.-L., Wu, C.-Y., Lin, K.-C. & Lur, S.-Y. Quantitative mechanical properties of the relaxed biceps and triceps brachii muscles in patients with subacute stroke: A reliability study of the myoton-3 myometer. Stroke Res. Treat. 2012, 617694 (2012).
- Jafari, M., Bahrpeyma, F., Mokhtari-Dizaji, M. & Nasiri, A. Novel method to measure active myofascial trigger point stiffness using ultrasound imaging. J. Bodyw. Mov. Ther. 22, 374–378 (2018). · DOI
- Periyasamy, R., Anand, S. & Ammini, A. C. Investigation of Shore meter in assessing foot sole hardness in patients with diabetes mellitus - a pilot study. Int. J. Diabetes Dev. Ctries. 32, 169–175 (2012). · doi:10.1007/s13410-012-0085-z
- Jędrzejewski, G. et al. The rolf method of structural integration on fascial tissue stiffness, elasticity, and superficial blood perfusion in healthy individuals: The prospective. Interv. Study Front. Physiol. 11, 1062 (2020). · DOI
- Cohen, J. Statistical Power Analysis for the Behavioral Sciences (Academic Press, 1977).
- Fleiss, J. Reliability of measurement. in Design and Analysis of Clinical Experiments 1–32 (Wiley, 2011). · DOI · Paper page
- Furlan, L. & Sterr, A. The applicability of standard error of measurement and minimal detectable change to motor learning research—A behavioral study. Front. Hum. Neurosci. 12, 95 (2018). · DOI · Paper page
- Schmitt, J. S. & Di Fabio, R. P. Reliable change and minimum important difference (MID) proportions facilitated group responsiveness comparisons using individual threshold criteria. J. Clin. Epidemiol. 57, 1008–1018 (2004). · DOI · Paper page
- Wilke, J. & Banzer, W. Non-invasive screening of fascial tissues—A narrative review. Phys. Medizin Rehabil. Kurortmedizin 24, 117–124 (2014). · doi:10.1055/s-0034-1370952
- Taljanovic, M. S. et al. Shear-wave elastography: Basic physics and musculoskeletal applications. Radiographics 37, 855–870 (2017). · DOI · Paper page
- Sigrist, R. M. S., Liau, J., Kaffas, A. E., Chammas, M. C. & Willmann, J. K. Ultrasound elastography: Review of techniques and clinical applications. Theranostics 7, 1303–1329 (2017). · DOI · Paper page
- Chakouch, M. K., Pouletaut, P., Charleux, F. & Bensamoun, S. F. Viscoelastic shear properties of in vivo thigh muscles measured by MR elastography. J. Magn. Reson. Imaging 43, 1423–1433 (2016). · DOI
- Chakouch, M. K., Charleux, F. & Bensamoun, S. F. New magnetic resonance elastography protocols to characterise deep back and thigh muscles. Comput. Methods Biomech. Biomed. Engin. 17(Suppl 1), 32–33 (2014). · doi:10.1080/10255842.2014.931086
- Strzalkowski, N. D. J., Triano, J. J., Lam, C. K., Templeton, C. A. & Bent, L. R. Thresholds of skin sensitivity are partially influenced by mechanical properties of the skin on the foot sole. Physiol. Rep. 3, e12425 (2015). · DOI
- Beaudette, S. M., Zwambag, D. P., Bent, L. R. & Brown, S. H. M. Spine postural change elicits localized skin structural deformation of the trunk dorsum in vivo. J. Mech. Behav. Biomed. Mater. 67, 31–39 (2017). · DOI
- Holowka, N. B. et al. Foot callus thickness does not trade off protection for tactile sensitivity during walking. Nature 571, 261–264 (2019). · DOI · Paper page
- Helili, M. et al. An investigation of regional plantar soft tissue hardness and its potential correlation with plantar pressure distribution in healthy adults. Appl. Bionics Biomech. 2021, 5566036 (2021). · DOI
- Duan, Y. et al. Relationship between plantar tissue hardness and plantar pressure distributions in people with diabetic peripheral neuropathy. Front. Bioeng. Biotechnol. 10, 836018 (2022). · DOI
- Chatzistergos, P. E., Allan, D., Chockalingam, N. & Naemi, R. Shore hardness is a more representative measurement of bulk tissue biomechanics than of skin biomechanics. Med. Eng. Phys. 105, 103816 (2022). · DOI
- Spears, I. R. & Miller-Young, J. E. The effect of heel-pad thickness and loading protocol on measured heel-pad stiffness and a standardized protocol for inter-subject comparability. Clin. Biomech. 21, 204–212 (2006). · doi:10.1016/j.clinbiomech.2005.09.017
- Feng, Y. N., Li, Y. P., Liu, C. L. & Zhang, Z. J. Assessing the elastic properties of skeletal muscle and tendon using shearwave ultrasound elastography and MyotonPRO. Sci. Rep. 8, 17064 (2018). · DOI · Paper page
- Wilke, J., Schwiete, C. & Behringer, M. Effects of maximal eccentric exercise on deep fascia stiffness of the knee flexors: A pilot study using shear-wave elastography. J. Sport. Sci. Med. 21, 419–425 (2022). · DOI
- Cheung, W. K., Cheung, J. P. Y. & Lee, W.-N. Role of ultrasound in low back pain: A review. Ultrasound Med. Biol. 46, 1344–1358 (2020). · DOI
- Kawchuk, G. N. et al. Clinicians’ ability to detect a palpable difference in spinal stiffness compared with a mechanical device. J. Manip. Physiol. Ther. 42, 89–95 (2019). · DOI
- Maher, C. G., Latimer, J. & Adams, R. An investigation of the reliability and validity of posteroanterior spinal stiffness judgments made using a reference-based protocol. Phys. Ther. 78, 829–837 (1998). · DOI
- Seffinger, M. A. et al. Reliability of spinal palpation for diagnosis of back and neck pain: A systematic review of the literature. Spine (Phila Pa 1976) 29, E413–E425 (2004). · DOI · Paper page
- Stolz, M., von Piekartz, H., Hall, T., Schindler, A. & Ballenberger, N. Evidence and recommendations for the use of segmental motion testing for patients with LBP—A systematic review. Musculoskelet. Sci. Pract. 45, 102076 (2020). · DOI
- Wong, R., Geyer, S., Weninger, W., Guimberteau, J.-C. & Wong, J. K. The dynamic anatomy and patterning of skin. Exp. Dermatol. 25, 92–98 (2016). · DOI · Paper page
- Moseley, L. G. I can’t find it! distorted body image and tactile dysfunction in patients with chronic back pain. Pain 140, 239–243 (2008). · DOI · Paper page
- Catley, M. J., O’Connell, N. E., Berryman, C., Ayhan, F. F. & Moseley, G. L. Is tactile acuity altered in people with chronic pain? A systematic review and meta-analysis. J. Pain 15, 985–1000 (2014). · DOI · Paper page
- Guimberteau, J. C., Delage, J. P., McGrouther, D. A. & Wong, J. K. F. The microvacuolar system: How connective tissue sliding works. J. Hand Surg. Eur. 35, 614–622 (2010). · DOI
- Berikol, G., Ekşi, M. Ş, Aydın, L., Börekci, A. & Özcan-Ekşi, E. E. Subcutaneous fat index: A reliable tool for lumbar spine studies. Eur. Radiol. 32, 6504–6513 (2022). · DOI
- Brown, R. B. Non-specific low back pain, dietary salt intake, and posterior lumbar subcutaneous edema. Int. J. Environ. Res. Public Health 19, 9158 (2022). · DOI
- Hides, J., Gilmore, C., Stanton, W. & Bohlscheid, E. Multifidus size and symmetry among chronic LBP and healthy asymptomatic subjects. Man. Ther. 13, 43–49 (2008). · DOI · Paper page
- Kjaer, P., Bendix, T., Sorensen, J. S., Korsholm, L. & Leboeuf-Yde, C. Are MRI-defined fat infiltrations in the multifidus muscles associated with low back pain?. BMC Med. 5, 2 (2007). · DOI · Paper page
- Krause, F., Wilke, J., Niederer, D., Vogt, L. & Banzer, W. Acute effects of foam rolling on passive stiffness, stretch sensation and fascial sliding: A randomized controlled trial. Hum. Mov. Sci. 67, 102514 (2019). · DOI
- Wang, Y., Jacobson, D. S. & Urban, M. W. A non-invasive method to estimate the stress-strain curve of soft tissue using ultrasound elastography. Ultrasound Med. Biol. 48, 786–807 (2022). · doi:10.1016/j.ultrasmedbio.2021.12.016
- Deurenberg, P., Yap, M. & van Staveren, W. A. Body mass index and percent body fat: a meta analysis among different ethnic groups. Int. J. Obes. Relat. Metab. Disord. J. Int. Assoc. Study Obes. 22, 1164–1171 (1998). · DOI · Paper page
- Fedewa, M. V. et al. Examining race-related error in two-compartment models of body composition assessment: A systematic review and meta-analysis. J. Clin. Densitom. Off. J. Int. Soc. Clin. Densitom. 24, 156–168 (2021). · DOI
- Oguntade, A. S. et al. Body composition and risk of heart failure: protocol for a systematic review and meta-analysis. Open Heart 8, e001632 (2021). · DOI
- Barone, M. et al. Assessment of body composition: Intrinsic methodological limitations and statistical pitfalls. Nutrition 102, 111736 (2022). · DOI
Cited by
Bouffandeau, A., Poisbleau, D., Ouidja, M. O. I., Karasinski, P., Papy, D., Flouzat-Lachaniette, C.-H., Bosc, R., Hersant, B., Meningaud, J.-P., & Haiat, G. (2026) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2026.107451 · Cited by 2
Bouffandeau, A., Poisbleau, D., Ouidja, M. O. I., Karasinski, P., Papy, D., Flouzat-Lachaniette, C.-H., Bosc, R., Hersant, B., Meningaud, J.-P., & Haiat, G. (2026) · arXiv · doi:10.48550/arxiv.2611.20949 · Cited by 2
Metadata
- Authors
- Bartsch, K., Brandl, A., Weber, P., Wilke, J., Bensamoun, S. F., Bauermeister, W., Klingler, W., & Schleip, R.
- Venue
- Scientific Reports
- Published
- 2023-01-16
- Volume
- 13
- Issue
- 1
- ISSN
- 2045-2322
- Cited by
- 83
- References
- 2
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Funders
- Technische Universität München
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing reliability and validity of different stiffness measurement tools on a multi-layered phantom tissue model. https://app.cochat.ai/papers/10.1038/s41598-023-27742-w
- The paper
- Bartsch, K., Brandl, A., Weber, P., Wilke, J., Bensamoun, S. F., Bauermeister, W., Klingler, W., & Schleip, R. (2023). Assessing reliability and validity of different stiffness measurement tools on a multi-layered phantom tissue model. Scientific Reports. https://doi.org/10.1038/s41598-023-27742-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.