Effects of MRI scanner manufacturers in classification tasks with deep learning models
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Deep learning has become a leading subset of machine learning and has been successfully employed in diverse areas, ranging from natural language processing to medical image analysis. In medical imaging, researchers have progressively turned towards multi-center neuroimaging studies to address complex questions in neuroscience, leveraging larger sample sizes and aiming to enhance the accuracy of deep learning models. However, variations in image pixel/voxel characteristics can arise between centers due to factors including differences in magnetic resonance imaging scanners. Such variations create challenges, particularly inconsistent performance in machine learning-based approaches, often referred to as domain shift, where the trained models fail to achieve satisfactory or improved results when confronted with dissimilar test data. This study analyzes the performance of multiple disease classification tasks using multi-center MRI data obtained from three widely used scanner manufacturers (GE, Philips, and Siemens) across several deep learning-based networks. Furthermore, we investigate the efficacy of mitigating scanner vendor effects using ComBat-based harmonization techniques when applied to multi-center datasets of 3D structural MR images. Our experimental results reveal a substantial decline in classification performance when models trained on one type of scanner manufacturer are tested with data from different manufacturers. Moreover, despite applying ComBat-based harmonization, the harmonized images do not demonstrate any noticeable performance enhancement for disease classification tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“inconsistent feature distributions in multicenter imaging data resulting from technical heterogeneities—including differences in scanner manufacturers, magnetic field strengths (1.5T vs. 3T), and acquisition protocols—which compromise cross-site model generalizability (Kushol et al., 2023).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Kushol et al., 2023
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
Dosovitskiy, A., Beyer, L., Kolesnikov, A., Weissenborn, D., Zhai, X., Unterthiner, T., Dehghani, M., Minderer, M., Heigold, G., Gelly, S., et al. (2020) · arXiv · doi:10.48550/arxiv.2010.11929 · Cited by 47,472 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialPyTorch: An Imperative Style, High-Performance Deep Learning Library
Paszke, A., Gross, S., Massa, F., Lerer, A., Bradbury, J., Chanan, G., Killeen, T., Lin, Z., Gimelshein, N., Antiga, L., et al. (2019) · arXiv · doi:10.48550/arxiv.1912.01703 · Cited by 31,473 · cited 1×
“The DL frameworks employed in our analysis are implemented using PyTorch 36”
MobileNetV2: Inverted Residuals and Linear Bottlenecks
Sandler, M., Howard, A., Zhu, M., Zhmoginov, A., & Chen, L.-C. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00474 · Cited by 28,755 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialProceedings of IEEE Conference on Computer Vision and Pattern Recognition
(1993) · Proceedings of IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1993.341010 · Cited by 14,265
Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526 · cited 1×
“This task is achieved using the FreeSurfer program 27 (Command: mri_synthstrip -i input_image -o stripped_image ) 3 .”
ShuffleNet V2: Practical Guidelines for Efficient CNN Architecture Design
Ma, N., Zhang, X., Zheng, H.-T., & Sun, J. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01264-9_8 · Cited by 7,356 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialN4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073 · cited 1×
“Subsequently, we perform N4 bias field correction using the SimpleITK library’s N4BiasFieldCorrec-tionImageFilter class to rectify low-frequency intensity non-uniformity in the MRI data 28 .”
Dimensionality reduction for visualizing single-cell data using UMAP
Becht, E., McInnes, L., Healy, J., Dutertre, C.-A., Kwok, I. W. H., Ng, L. G., Ginhoux, F., & Newell, E. W. (2019) · Nature Biotechnology · doi:10.1038/nbt.4314 · Cited by 5,358 · cited 1×
“Subsequently, we employ t-SNE (t-distributed Stochastic Neighbor Embedding) 37 and UMAP (Uniform Manifold Approximation and Projection) 38 techniques to visualize the data in a 2D space, using features generated by MRQy 39 .”
Research works printed but not linked: 1
- Van der Maaten L Hinton G Visualizing data using t-sne J. Mach. Learn. Res. 2008 9 896
Cited by
The power of deep learning in simplifying feature selection for hepatocellular carcinoma: a review
Mostafa, G., Mahmoud, H. A., El‐Hafeez, T. A., & E.ElAraby, M. (2024) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-024-02682-1 · Cited by 103
“These CNN algorithms, trained on diverse imaging modalities such as ultrasound, computed tomography (CT) [39], and magnetic resonance imaging (MRI), have demonstrated exceptional performance in various tasks [40].”
MethodAhmed, N., Saha, A. K., Noman, M. A. A., Jim, J. R., Mridha, M. F., & Kabir, M. M. (2024) · Natural Language Processing Journal · doi:10.1016/j.nlp.2024.100112 · Cited by 69
A generalizable foundation model for analysis of human brain MRI
Tak, D., Garomsa, B., Zapaishchykova, A., Chaunzwa, T., Pardo, J. C. C., Ye, Z.-Z., Zielke, J., Ravipati, Y., Pai, S., Vajapeyam, S., et al. (2026) · Nature Neuroscience · doi:10.1038/s41593-026-02202-6 · Cited by 80
“Furthermore, magnetic resonance acquisition itself is subject to variability and noise, with a range of scanners (from 1.5 T to 7 T) and differing acquisition parameters (for example, echo time or relaxation time) 24 .”
Influentialde Almeida, J. G., Messiou, C., Withey, S. J., Matos, C., Koh, D.-M., & Papanikolaou, N. (2025) · European Radiology · doi:10.1007/s00330-025-11654-6 · Cited by 23
Jia, W., Li, H., Ali, R. A., Shanbhogue, K., Masch, W. R., Aslam, A., Harris, D. T., Reeder, S. B., Dillman, J. R., & He, L. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-01253-0 · Cited by 25
“For example, Kushol et al. found that harmonized images generated by the ComBat method fail to enhance the classification accuracy in most of their brain MR image classification applications [42].”
In the Picture: Medical Imaging Datasets, Artifacts, and their Living Review
Jiménez-Sánchez, A., Avlona, N.-R., de Boer, S., Campello, V. M., Feragen, A., Ferrante, E., Ganz, M., Gichoya, J. W., González, C., Groefsema, S., et al. (2025) · ACM Conference on Fairness, Accountability, and Transparency (FAccT) · doi:10.1145/3715275.3732035 · Cited by 36
A multi-site, multi-modal travelling-heads resource for brain MRI harmonisation
Warrington, S., Torchi, A., Mougin, O. E., Campbell, J., Ntata, A., Craig, M., Assimopoulos, S., Alfaro‐Almagro, F., Miller, K. L., Jenkinson, M., et al. (2025) · Scientific Data · doi:10.1038/s41597-025-04822-2 · Cited by 23
“…observe that between-scanner within-participant variability can be as large and occasionally exceed between-participant within-scanner variability for a number of IDP groups, in agreement with what has been reported before 10,50,51 , highlighting the need for harmonisation in between-scanner data.”
Müller, H., & Kassubek, J. (2024) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2024.1378896 · Cited by 15
A foundation model for generalized brain MRI analysisPreprint
Tak, D., Garomsa, B. A., Chaunzwa, T. L., Zapaishchykova, A., Pardo, J. C. C., Ye, Z., Zielke, J., Ravipati, Y., Vajapeyam, S., Mahootiha, M., et al. (2024) · medRxiv · doi:10.1101/2024.12.02.24317992 · Cited by 13
Chen, W., Kuo, L., Lin, Y.-X., Yu, W., Tseng, C., Lin, Y., Huang, C.-C., Chang, S., Wu, J. C., Chen, C.-K., et al. (2024) · International Journal of Biomedical Imaging · doi:10.1155/2024/6114826 · Cited by 17
Evaluation of Image‐Level Harmonization Methods for Multi‐Center MR Neuroimaging
Ho, B. C., Kim, D., Kumar, A., Weiss, S. E., Vossler, H. A., Mormino, E. C., Zaharchuk, G., & Initiative, T. F. L. D. N. (2026) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.70221 · Cited by 12
“Our findings with ComBat are consistent with the mixed results reported in the literature when applying this method in voxel-level harmonization [28, 29].”
España‐Irla, G., Tinney, E. M., Ai, M., Nwakamma, M. C., & Morris, T. P. (2025) · Human Brain Mapping · doi:10.1002/hbm.70237 · Cited by 11
Rodrigues, A. C., Almeida, J. G., Rodrigues, N. M., Moreno, R., Verde, A. S. C., Gaivão, A. M., Bilreiro, C., Santiago, I., Ip, J., Belião, S., et al. (2025) · Radiology Imaging Cancer · doi:10.1148/rycan.240507 · Cited by 16
“As shown by our sensitivity analysis, models trained on individual vendors fail to generalize when tested on data from other vendors, confirming previous findings in the literature pertaining to classification (44,45) and segmentation (22,46).”
Dang, M., Liu, B., Chen, Y., & Zhang, Z. (2026) · Psychoradiology · doi:10.1093/psyrad/kkag007 · Cited by 10
Rethinking MRI as a measurement device through modular and portable pipelines
Karakuzu, A., Blostein, N., Caron, A. V., Boré, A., Rheault, F., Descoteaux, M., & Stikov, N. (2025) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-025-01245-3 · Cited by 11
Rodrigues, N. M., de Almeida, J. G., Verde, A. S. C., Gaivão, A. M., Bireiro, C., Santiago, I., Ip, J., Belião, S., Matos, C., Vanneschi, L., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-99795-y · Cited by 7
“…models have the benefit of producing consistent results provided the input data is identical, with the caveat that performance degradation is common when transferring models between scanner manufacturers 8 or, in the case of prostate bpMRI, scanner manufacturers and the use of endorectal coil.”
High-quality multimodal MRI with simultaneous EEG using conductive ink and polymer-thick film nets
Cicero, N. G., Fultz, N. E., Jeong, H., Williams, S. D., Gomez, D. E. P., Setzer, B., Warbrick, T., Jaschke, M., Gupta, R., Lev, M. H., et al. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad8837 · Cited by 9
From promise to practice: a scoping review of AI applications in abdominal radiology
Fotis, A., Lalwani, N., Gupta, P. K., & Yee, J. (2025) · Abdominal Radiology · doi:10.1007/s00261-025-05144-y · Cited by 5
Trends in brain MRI and CP association using deep learning
Hassan, M. A., Lin, J., Fateh, A. A., Zhuang, Y., Lin, G., Khan, D., Mohammed, A. A. Q., & Zeng, H. (2024) · La radiologia medica · doi:10.1007/s11547-024-01893-w · Cited by 6
Jannat, S. R., Lynch, K. M., Fotouhi, M., Cen, S., Choupan, J., Sheikh‐Bahaei, N., Pandey, G., & Varghese, B. A. (2025) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2025.1532395 · Cited by 8
Tariq, U., Ahmed, I., Shaukat, K., & Ihsan, M. (2026) · International Journal of Computational Intelligence Systems · doi:10.1007/s44196-026-01283-2 · Cited by 4
MRAnnotator: multi-anatomy and many-sequence MRI segmentation of 44 structures
Zhou, A., Liu, Z., Tieu, A., Patel, N. R., Sun, S., Yang, A., Choi, P., Lee, H.-C., Tordjman, M., Deyer, L., et al. (2024) · Radiology Advances · doi:10.1093/radadv/umae035 · Cited by 10
“10,11 Recently, Kirillov et al. 12 proposed the concept of “Segment Anything,” demonstrating that models trained on a large-scale segmentation dataset can be generalized across a wide range of downstream segmentation tasks.”
Decoding dynamic brain networks in Parkinson’s disease with temporal attention
Patel, S. B., FitzGerald, J. J., & Antoniades, C. A. (2025) · Scientific Reports · doi:10.1038/s41598-025-01106-y · Cited by 4
Contrastive Anatomy-Contrast Disentanglement: A Domain-General MRI Harmonization Method
Scholz, D., Erdur, A. C., Holland, R., Ehm, V., Peeken, J. C., Wiestler, B., & Rueckert, D. (2025) · Lecture notes in computer science · doi:10.1007/978-3-032-04978-0_10 · Cited by 3
“Variations in pulse sequences, acquisition parameters, and scanner hardware can cause undesired contrast variations, particularly in multi-site and longitudinal studies [15,9].”
Du, Q., Kong, W., Chang, Y., Xin, Z., Shao, X., Feng, L., Zhou, J., Zhang, Y., Li, X. H., Cao, G., et al. (2026) · Spine · doi:10.1097/brs.0000000000005639 · Cited by 3
A Multiple Sclerosis MRI Dataset with Tri-Mask Annotations for Lesion Segmentation
Bawil, M. B., Shamsi, M., Ghalehasadi, A., Jafargholkhanloo, A. F., & Bavil, A. S. (2026) · Scientific Data · doi:10.1038/s41597-026-07184-5 · Cited by 5
Lillebostad, P. A. G., Njølstad, T. S., Hogstad, S., Riemer, F., Kverneng, S. U., Stige, K. E., Biermann, M., Jog, M., Buch, S., Haacke, E. M., et al. (2025) · Imaging Neuroscience · doi:10.1162/imag.a.158 · Cited by 3
“The challenge of generalization across sites and scanners— known as domain shift— is one of the major challenges facing the field of deep learning for medical imaging ( Kushol et al., 2023; M å rtensson et al., 2020), and is difficult to spot in the absence of explicit scrutiny.”
Raskin, D., Klang, E., Barash, Y., Korfiatis, P. D., Partovi, S., McCarthy, C. J., Nadkarni, G. N., Collins, J. D., & Sorin, V. (2025) · European Journal of Radiology · doi:10.1016/j.ejrad.2025.112456 · Cited by 3
Sam, F., Qin, Z., Sey, C., Arhin, J. R., Addo, D., Fiasam, L. D., Ayivi, W., & Muoka, G. W. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.108686 · Cited by 3
Li, S., Yang, M., Zhang, X., Chen, M., Wang, Y., Xiong, X., Duan, Z., Fu, K., & Lin, Z. (2026) · Measurement Science and Technology · doi:10.1088/1361-6501/ae5e36 · Cited by 2
Shakeri, M., Mostaar, A., Sadeghi, A. Z., Hosseini, S. M., Joybari, A. Y., & Ghadiri, H. (2024) · Journal of Medical Physics · doi:10.4103/jmp.jmp_149_24 · Cited by 2
“[58] Voxel intensity values can also be affected by these differences, possibly hiding or simulating pathological alterations in the healthy tissue.”
Cardiovascular Magnetic Resonance imaging analysis using neural networks
Wang, L. M., Wang, L. M., Wu, P., & Ding, L. (2025) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2025.101874 · Cited by 6
Moroze, E., Zikopoulos, B., & Yazdanbakhsh, A. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.11.17.688918 · Cited by 2
“It has been found that CNNs can distinguish between MRI data taken from multiple centers/scanner brands with no other obvious differences 29,30 .”
Skull-stripping induces shortcut learning in MRI-based Alzheimer’s disease classification
Tinauer, C., Sackl, M., Stollberger, R., Schmidt, R., Ropele, S., & Langkammer, C. (2025) · Insights into Imaging · doi:10.1186/s13244-025-02158-4 · Cited by 9
“Lastly, while heatmaps and similarity metrics were effective for feature interpretation, they may not fully capture the intricate interactions between features learned by the models.”
Kim, J. J., Kim, J. Y., Hwangbo, L., Lee, H. J., Lee, N. K., Lee, J. M., & Liu, W. (2026) · European Journal of Radiology · doi:10.1016/j.ejrad.2026.113159 · Cited by 1
HeteroMRI: Robust white matter abnormality classification across multi-scanner MRI data
Abedi, M., Shekarchizadeh, N., Bazin, P., Scherf, N., Lier, J., Bergner, C., Initiative, A. D. N., Köhler, W., & Kirsten, T. (2025) · GigaScience · doi:10.1093/gigascience/giaf092 · Cited by 1
“Statistical techniques such as intensity normalization [ 26 , 41 ] or ComBat-based batch effect correction [ 31–36 ] have shown success to some extent, but often fail to improve DL model performance in disease classification tasks [ 37 ].”
DeepDSMRI: Deep Domain Shift Analyzer for MRI
Kushol, R., Kalra, S., & Yang, Y. (2024) · Lecture notes in computer science · doi:10.1007/978-3-031-66955-2_6
Self-citationJaganath, M. S., Shri, G. R., Bharani, B. I., Kumar, S. G. M., Haris, S. S., & Karneya, B. (2025) · International Conference on Visual Analytics and Data Visualization (ICVADV) · doi:10.1109/icvadv63329.2025.10961162
“These days, even a basic mobile phone may be transformed into an effective medical instrument [9].”
AlexNet-Based Deep Learning Model for Automated MRI Scan Classification
Sheikdavood, K., Arun, A., Reaz, M. B. I., Balamani, T., Mohanavel, G., & Logarasu, R. (2025) · International Conference on Data Intelligence and Cognitive Informatics (ICDICI) · doi:10.1109/icdici66477.2025.11135005
“Nowadays, even a simple mobile phone can be turned into a powerful medical device [9].”
NeuroFusion: A forensic enriched ensemble framework for cerebellum disease classification
Hanzala, A., Sajjad, M., Akter, T., Kaur, H., & Rahman, M. S. (2025) · Neuroscience Informatics · doi:10.1016/j.neuri.2025.100251
Shahraki, B., Montazerabadi, A., Valizadeh, M., Lotfi, P., & Ghorbani, F. (2026) · Hemoglobin · doi:10.1080/03630269.2025.2609992
“Vendor-specific differences in MRI hardware and software, as noted by Kushol et al. [24], affect signal processing and final quantification.”
Zeng, G., Min, X., Xu, Z., Maimaitizunong, S., Fan, W., Qiao, F., Nan, Y., Chen, P., Chen, Z., & Yin, X. (2026) · International Journal of Clinical Practice · doi:10.1155/ijcp/4651616
Sharifian, P., Azimi, M.-S., Noroozi, M., Karimian, A., & Arabi, H. (2025) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme68496.2025.11392296 · Cited by 1
“Finally, we provide a multi-faceted validation: quantitative metrics show a major boost in balanced accuracy, while t-SNE visualizations offer qualitative proof of successful feature distribution alignment post-harmonization.”
Sun, Y., Wang, K., & Ye, T. (2026) · Cellular and Molecular Neurobiology · doi:10.1007/s10571-026-01705-x
“For imaging-based AI pipelines, standardized data representations most commonly DICOM or NIfTI formats are required, accompanied by harmonized voxel resolution, intensity normalization, and consistent acquisition metadata to minimize scanner-and site-related variability (Kushol et al. 2023).”
Hua, C., Wang, X.-L., & Sheng, H. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1758568 · Cited by 1
Sim, J. Z. T., Ge, X., Low, H. M., & Lee, C. H. (2026) · Livers · doi:10.3390/livers6020021
“Third, this study was limited to MR examinations performed on scanners from two vendors (Siemens and Philips), which may restrict the generalizability of our findings across other manufacturers [41].”
Transfer learning and domain adaptation in neuroinformatics
Lawal, M. A., Abayomi, A., Salihu, A. A., Aliyu, A. A., Aliyu, M. A., & Yakubu, I. Z. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-41459-6.00007-9 · Cited by 2
Cross-Scanner Reliability of Brain MRI Foundation Models: A Travelling-Heads StudyPreprint
González, R. N., Caballero-Lillo, P., Gallo, A., Aja‐Fernández, S., Planchuelo‐Gómez, Á., & de Luis-García, R. (2026) · medRxiv · doi:10.64898/2026.03.23.26348808 · Cited by 1
Dibble, A. J., Dalby, C., Sevegnani, M., Fracasso, A., Lyall, D. M., Harvey, M., Svanera, M., Initiative, T. F. L. D. N., & Initiative, T. F. L. D. N. (2026) · medRxiv · doi:10.64898/2026.03.27.26349489 · Cited by 3
Letter to the Editor: Beyond external validation: Is TED-Net ready for real-world generalization?
Tang, W., & Yang, W. (2026) · European Radiology · doi:10.1007/s00330-026-12802-2
Chen, L. (2026) · IEEE International Conference on Electronics, Energy Systems and Power Engineering (EESPE) · doi:10.1109/eespe68405.2026.11649052
“…performance on more advanced cases further suggests that deep learning models may complement radiological assessment by providing consistent, reproducible evaluations of structural degeneration, which has been proposed as a promising direction for integrating AI into dementia care pathways [13].”
Fallah, S., & Herzog, N. J. (2026) · Journal of Imaging · doi:10.3390/jimaging12090426
“Multi-site acquisition introduces further confounds, as scanner-dependent intensity distributions across ADNI’s 54 sites are classifiable by manufacturer with approximately 99% accuracy [5].”
Anuradha, M., Thenneti, A., Khan, M. Z. A. A., Madichetty, S. S., Bussa, N. S., & Godnaha, U. (2026) · IEEE World Conference on Applied Intelligence and Computing (AIC) · doi:10.1109/aic70896.2026.11717354
“…and contrast variations on every image they produce, differences in field homogeneity, gradient hardware, coil sensitivity, and reconstruction pipelines create scanner-specific signatures that survive standard preprocessing [16] and are invisible unless using systems to detect site loss and LOSO .”
A Clinical Primer on Computer Vision
Parkinson, J., & Lindner, C. (2026) · Calcified Tissue International · doi:10.1007/s00223-026-01620-9
Metadata
- Authors
- Kushol, R., Parnianpour, P., Wilman, A. H., Kalra, S., & Yang, Y.-H.
- Affiliations
- University of Alberta (CA)
- Corresponding author
- Kushol, Rafsanjany
- Venue
- Scientific Reports
- Published
- 2023-10-05
- Volume
- 13
- Issue
- 1
- Pages
- 16791-16791
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC10556074
- OpenAlex
- W4387376141
- Semantic Scholar
- 97dba224ea71c3d29332667aa5861e19c0bc2e46
- Cited by
- 54
- References
- 44
- Citations by year
- 2026: 21 · 2025: 22 · 2024: 11
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- ALS Society of Canada (100009017)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (501100002790)
- Fondation Brain Canada (100009408)
- Gouvernement du Canada | Canadian Institutes of Health Research (501100000024)
- Prime Minister Fellowship Bangladesh
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Computer Science › Artificial Intelligence › Domain Adaptation and Few-Shot Learning
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Keywords
- domain shift, multi-center MRI, structural MRI, combat, image harmonization, disease classification, neuroimaging, deep learning
- MeSH terms
- Machine Learning, Deep Learning, Magnetic Resonance Imaging, Natural Language Processing, Neuroimaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.