Effects of MRI scanner manufacturers in classification tasks with deep learning models
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Deep learning has become a leading subset of machine learning and has been successfully employed in diverse areas, ranging from natural language processing to medical image analysis. In medical imaging, researchers have progressively turned towards multi-center neuroimaging studies to address complex questions in neuroscience, leveraging larger sample sizes and aiming to enhance the accuracy of deep learning models. However, variations in image pixel/voxel characteristics can arise between centers due to factors including differences in magnetic resonance imaging scanners. Such variations create challenges, particularly inconsistent performance in machine learning-based approaches, often referred to as domain shift, where the trained models fail to achieve satisfactory or improved results when confronted with dissimilar test data. This study analyzes the performance of multiple disease classification tasks using multi-center MRI data obtained from three widely used scanner manufacturers (GE, Philips, and Siemens) across several deep learning-based networks. Furthermore, we investigate the efficacy of mitigating scanner vendor effects using ComBat-based harmonization techniques when applied to multi-center datasets of 3D structural MR images. Our experimental results reveal a substantial decline in classification performance when models trained on one type of scanner manufacturer are tested with data from different manufacturers. Moreover, despite applying ComBat-based harmonization, the harmonized images do not demonstrate any noticeable performance enhancement for disease classification tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“inconsistent feature distributions in multicenter imaging data resulting from technical heterogeneities—including differences in scanner manufacturers, magnetic field strengths (1.5T vs. 3T), and acquisition protocols—which compromise cross-site model generalizability (Kushol et al., 2023).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Kushol et al., 2023
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet: A large-scale hierarchical image database
Deng, J., Dong, W., Socher, R., Li, L.-J., Li, K., & Fei-Fei, L. (2009) · 2009 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2009.5206848 · Cited by 65,333
An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
Dosovitskiy, A., Beyer, L., Kolesnikov, A., Weissenborn, D., Zhai, X., Unterthiner, T., Dehghani, M., Minderer, M., Heigold, G., Gelly, S., et al. (2020) · arXiv · doi:10.48550/arxiv.2010.11929 · Cited by 47,472 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialPyTorch: An Imperative Style, High-Performance Deep Learning Library
Paszke, A., Gross, S., Massa, F., Lerer, A., Bradbury, J., Chanan, G., Killeen, T., Lin, Z., Gimelshein, N., Antiga, L., et al. (2019) · arXiv · doi:10.48550/arxiv.1912.01703 · Cited by 31,473 · cited 1×
“The DL frameworks employed in our analysis are implemented using PyTorch 36”
MobileNetV2: Inverted Residuals and Linear Bottlenecks
Sandler, M., Howard, A., Zhu, M., Zhmoginov, A., & Chen, L.-C. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00474 · Cited by 28,755 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialProceedings of IEEE Conference on Computer Vision and Pattern Recognition
(1993) · Proceedings of IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.1993.341010 · Cited by 14,265
Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526 · cited 1×
“This task is achieved using the FreeSurfer program 27 (Command: mri_synthstrip -i input_image -o stripped_image ) 3 .”
ShuffleNet V2: Practical Guidelines for Efficient CNN Architecture Design
Ma, N., Zhang, X., Zheng, H.-T., & Sun, J. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01264-9_8 · Cited by 7,356 · cited 4×
“Initially, we employ three 3D DL-based classification networks (ResNet 31 , MobileNetV2 33 , ShuffleNetV2 32 ) using MRI data to classify three distinct scanner manufacturers (GE, Philips, and Siemens).”
InfluentialN4ITK: Improved N3 Bias Correction
Tustison, N. J., Avants, B. B., Cook, P. A., Zheng, Y., Egan, A., Yushkevich, P. A., & Gee, J. C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2046908 · Cited by 6,073 · cited 1×
“Subsequently, we perform N4 bias field correction using the SimpleITK library’s N4BiasFieldCorrec-tionImageFilter class to rectify low-frequency intensity non-uniformity in the MRI data 28 .”
Dimensionality reduction for visualizing single-cell data using UMAP
Becht, E., McInnes, L., Healy, J., Dutertre, C.-A., Kwok, I. W. H., Ng, L. G., Ginhoux, F., & Newell, E. W. (2019) · Nature Biotechnology · doi:10.1038/nbt.4314 · Cited by 5,358 · cited 1×
“Subsequently, we employ t-SNE (t-distributed Stochastic Neighbor Embedding) 37 and UMAP (Uniform Manifold Approximation and Projection) 38 techniques to visualize the data in a 2D space, using features generated by MRQy 39 .”
A reproducible evaluation of ANTs similarity metric performance in brain image registration
Avants, B. B., Tustison, N. J., Song, G., Cook, P. A., Klein, A., & Gee, J. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.025 · Cited by 4,796
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347 · cited 11×
“The ADNI has satisfied our initial criterion, which offers the most extensive collection of publicly accessible research data resources, including imaging, clinical, and genomic data.”
InfluentialKowalska, M., Woźniak, M., Kijek, M., Mitrosz, P., Szakiel, J., & Turek, P. (2022) · Scientific Reports · doi:10.1038/s41598-021-99269-x · Cited by 2,117
The Parkinson Progression Marker Initiative (PPMI)
Marek, K., Jennings, D., Lasch, S., Siderowf, A., Tanner, C., Simuni, T., Coffey, C., Kieburtz, K., Flagg, E., Chowdhury, S., et al. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2011.09.005 · Cited by 1,892 · cited 9×
“Notably, in the PPMI dataset, using data from Siemens and GE also yields an average accuracy of around 90%, while using Philips data results in an approximate classification accuracy of 85%.”
InfluentialHarmonization of cortical thickness measurements across scanners and sites
Fortin, J.-P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., Adams, P., Cooper, C., Fava, M., McGrath, P. J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.024 · Cited by 1,580
Han, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
Harmonization of multi-site diffusion tensor imaging data
Fortin, J.-P., Parker, D., Tunç, B., Watanabe, T., Elliott, M. A., Ruparel, K., Roalf, D. R., Satterthwaite, T. D., Gur, R. C., Gur, R. E., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.047 · Cited by 1,261
Liu, M., Li, F., Yan, H., Wang, K., Ma, Y., Shen, L., & Xu, M. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116459 · Cited by 568
Pomponio, R., Erus, G., Habes, M., Doshi, J., Srinivasan, D., Mamourian, E., Bashyam, V., Nasrallah, I. M., Satterthwaite, T. D., Fan, Y., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116450 · Cited by 524 · cited 1×
“Initially, we evaluate the outcomes of a modified ComBat-based method known as ComBat-generalized additive model (ComBat-GAM), specifically designed to address site effects in multi-site neuroimaging datasets 21 .”
SynthStrip: skull-stripping for any brain image
Hoopes, A., Mora, J. S., Dalca, A. V., Fischl, B., & Hoffmann, M. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119474 · Cited by 488
Qiu, S., Joshi, P. S., Miller, M. I., Xue, C., Zhou, X., Karjadi, C., Chang, G. H., Joshi, A. S., Dwyer, B., Zhu, S., et al. (2020) · Brain · doi:10.1093/brain/awaa137 · Cited by 472
Statistical normalization techniques for magnetic resonance imaging
Shinohara, R. T., Sweeney, E. M., Goldsmith, J., Shiee, N., Mateen, F. J., Calabresi, P. A., Jarso, S., Pham, D. L., Reich, D. S., & Crainiceanu, C. M. (2014) · NeuroImage: Clinical · doi:10.1016/j.nicl.2014.08.008 · Cited by 425 · cited 1×
“Lastly, we apply WhiteStripe intensity normalization using the Python intensity-normalization package 30 .”
Abd-Ellah, M. K., Awad, A. I., Khalaf, A. A. M., & Hamed, H. F. A. (2019) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2019.05.028 · Cited by 348
Dual attention multi-instance deep learning for Alzheimer’s disease diagnosis with structural MRI
Zhu, W., Sun, L., Huang, J., Han, L., & Zhang, D. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3077079 · Cited by 278
Radua, J., Vieta, E., Shinohara, R., Kochunov, P., Quidé, Y., Green, M. J., Weickert, C. S., Weickert, T., Bruggemann, J., Kircher, T., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116956 · Cited by 258
The Domain Shift Problem of Medical Image Segmentation and Vendor-Adaptation by Unet-GAN
Yan, W., Wang, Y., Gu, S., Huang, L., Yan, F., Xia, L., & Tao, Q. (2019) · Lecture notes in computer science · doi:10.1007/978-3-030-32245-8_69 · Cited by 190
Effect of data leakage in brain MRI classification using 2D convolutional neural networks
Yagis, E., Atnafu, S. W., García Seco de Herrera, A., Marzi, C., Scheda, R., Giannelli, M., Tessa, C., Citi, L., & Diciotti, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-01681-w · Cited by 161
Horng, H., Singh, A., Yousefi, B., Cohen, E. A., Haghighi, B., Katz, S. I., Noël, P. B., Shinohara, R. T., & Kontos, D. (2022) · Scientific Reports · doi:10.1038/s41598-022-08412-9 · Cited by 131
Harmonization of cortical thickness measurements across scanners and sitesPreprint
Fortin, J., Cullen, N. C., Sheline, Y. I., et al. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/148502 · Cited by 88
Harmonization of multi-site diffusion tensor imaging dataPreprint
Fortin, J., Parker, D., Tunç, B., et al. (2017) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/116541 · Cited by 84
Maikusa, N., Zhu, Y., Uematsu, A., Yamashita, A., Saotome, K., Okada, N., Kasai, K., Okanoya, K., Yamashita, O., Tanaka, S., et al. (2021) · Human Brain Mapping · doi:10.1002/hbm.25615 · Cited by 83
Effects of MRI scanner parameters on breast cancer radiomics
Saha, A., Yu, X., Sahoo, D., & Mazurowski, M. A. (2017) · Expert Systems with Applications · doi:10.1016/j.eswa.2017.06.029 · Cited by 79
Role of MRI in diagnosis and treatment of multiple sclerosis
Sahraian, M. A., & Eshaghi, A. (2010) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2010.03.022 · Cited by 70
Yan, W., Huang, L., Xia, L., Gu, S., Yan, F., Wang, Y., & Tao, Q. (2020) · Radiology: Artificial Intelligence · doi:10.1148/ryai.2020190195 · Cited by 66
Technical Note: MRQy — An open‐source tool for quality control of MR imaging data
Sadri, A. R., Janowczyk, A., Zhou, R., Verma, R., Beig, N., Antunes, J., Madabhushi, A., Tiwari, P., & Viswanath, S. E. (2020) · Medical Physics · doi:10.1002/mp.14593 · Cited by 63 · cited 4×
“Subsequently, we employ t-SNE (t-distributed Stochastic Neighbor Embedding) 37 and UMAP (Uniform Manifold Approximation and Projection) 38 techniques to visualize the data in a 2D space, using features generated by MRQy 39 .”
InfluentialAddformer: Alzheimer’s Disease Detection from Structural Mri Using Fusion Transformer
Kushol, R., Masoumzadeh, A., Huo, D., Kalra, S., & Yang, Y.-H. (2022) · 2022 IEEE 19th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi52829.2022.9761421 · Cited by 61
Self-citationCross–scanner harmonization methods for structural MRI may need further work: A comparison study
Gebre, R. K., Senjem, M. L., Raghavan, S., Schwarz, C. G., Gunter, J. L., Hofrenning, E. I., Reid, R. I., Kantarci, K., Graff‐Radford, J., Knopman, D. S., et al. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.119912 · Cited by 57
Tian, D., Zeng, Z., Sun, X., Tong, Q., Li, H., He, H., Gao, J., He, Y., & Xia, M. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119297 · Cited by 56
Kalra, S., Khan, M. H., Barlow, L. R., Beaulieu, C., Benatar, M. G., Briemberg, H., Chenji, S., Clua, M. G., Das, S. K., Dionne, A., et al. (2020) · medRxiv · doi:10.1101/2020.07.10.20142679 · Cited by 45 · cited 1×
“The Canadian ALS Neuroimaging Consortium (CALSN IC) 26 is the only prospective, multi-center and multimodal longitudinal study of ALS using harmonized clinical and imaging protocols across its sites.”
Self-citationDSMRI: Domain Shift Analyzer for Multi-Center MRI Datasets
Kushol, R., Wilman, A. H., Kalra, S., & Yang, Y. (2023) · Diagnostics · doi:10.3390/diagnostics13182947 · Cited by 32
Self-citationKushol, R., Luk, C., Dey, A., Benatar, M. G., Briemberg, H., Dionne, A., Dupré, N., Frayne, R., Genge, A. L., Gibson, S. B., et al. (2023) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2023.102279 · Cited by 27
Self-citationReliability assessment of tissue classification algorithms for multi-center and multi-scanner data
Dadar, M., Duchesne, S., & For the CCNA Group and the CIMA-Q Group (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116928 · Cited by 26
Joo, L., Jung, S. C., Lee, H., Park, S. Y., Kim, M., Park, J. E., & Choi, K. M. (2021) · Scientific Reports · doi:10.1038/s41598-021-96621-z · Cited by 19
Rbvs-Net: A Robust Convolutional Neural Network For Retinal Blood Vessel Segmentation
Kushol, R., & Salekin, M. S. (2020) · Proceedings - International Conference on Image Processing · doi:10.1109/icip40778.2020.9190759 · Cited by 11
Self-citationDomain Adaptation of MRI Scanners as an Alternative to MRI Harmonization
Kushol, R., Frayne, R., Graham, S. J., Wilman, A. H., Kalra, S., & Yang, Y. (2023) · Lecture notes in computer science · doi:10.1007/978-3-031-45857-6_1 · Cited by 9
Self-citationMRQy: An Open-Source Tool for Quality Control of MR Imaging DataPreprint
Sadri, A. R., Janowczyk, A. R., Zou, R., Verma, R., Beig, N., Antunes, J. T., Madabhushi, A., Tiwari, P., & Viswanath, S. E. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2004.04871 · Cited by 5 · cited 4×
“Subsequently, we employ t-SNE (t-distributed Stochastic Neighbor Embedding) 37 and UMAP (Uniform Manifold Approximation and Projection) 38 techniques to visualize the data in a 2D space, using features generated by MRQy 39 .”
InfluentialReliability Assessment of Tissue Classification Algorithms for Multi-Center and Multi-Scanner DataPreprint
Dadar, M., Duchesne, S., & For the CCNA Group and the CIMA-Q Group (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.01.28.922971 · Cited by 3
Tian, D., Zeng, Z., Sun, X., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.12.05.471192 · Cited by 3
Itahashi, T., Aoki, Y. Y., Yamashita, A., Soda, T., Fujino, J., Ohta, H., Aoki, R., Nakamura, M., Kato, N., Tanaka, S., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.10.31.466635 · Cited by 2
Research works printed but not linked: 1
- Van der Maaten L Hinton G Visualizing data using t-sne J. Mach. Learn. Res. 2008 9 896
Cited by
The power of deep learning in simplifying feature selection for hepatocellular carcinoma: a review
Mostafa, G., Mahmoud, H. A., El‐Hafeez, T. A., & E.ElAraby, M. (2024) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-024-02682-1 · Cited by 103
“These CNN algorithms, trained on diverse imaging modalities such as ultrasound, computed tomography (CT) [39], and magnetic resonance imaging (MRI), have demonstrated exceptional performance in various tasks [40].”
MethodAhmed, N., Saha, A. K., Noman, M. A. A., Jim, J. R., Mridha, M. F., & Kabir, M. M. (2024) · Natural Language Processing Journal · doi:10.1016/j.nlp.2024.100112 · Cited by 69
A generalizable foundation model for analysis of human brain MRI
Tak, D., Garomsa, B., Zapaishchykova, A., Chaunzwa, T., Pardo, J. C. C., Ye, Z.-Z., Zielke, J., Ravipati, Y., Pai, S., Vajapeyam, S., et al. (2026) · Nature Neuroscience · doi:10.1038/s41593-026-02202-6 · Cited by 80
“Furthermore, magnetic resonance acquisition itself is subject to variability and noise, with a range of scanners (from 1.5 T to 7 T) and differing acquisition parameters (for example, echo time or relaxation time) 24 .”
Influentialde Almeida, J. G., Messiou, C., Withey, S. J., Matos, C., Koh, D.-M., & Papanikolaou, N. (2025) · European Radiology · doi:10.1007/s00330-025-11654-6 · Cited by 23
Jia, W., Li, H., Ali, R. A., Shanbhogue, K., Masch, W. R., Aslam, A., Harris, D. T., Reeder, S. B., Dillman, J. R., & He, L. (2024) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-024-01253-0 · Cited by 25
“For example, Kushol et al. found that harmonized images generated by the ComBat method fail to enhance the classification accuracy in most of their brain MR image classification applications [42].”
Metadata
- Authors
- Kushol, R., Parnianpour, P., Wilman, A. H., Kalra, S., & Yang, Y.-H.
- Affiliations
- University of Alberta (CA)
- Corresponding author
- Kushol, Rafsanjany
- Venue
- Scientific Reports
- Published
- 2023-10-05
- Volume
- 13
- Issue
- 1
- Pages
- 16791-16791
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC10556074
- OpenAlex
- W4387376141
- Semantic Scholar
- 97dba224ea71c3d29332667aa5861e19c0bc2e46
- Cited by
- 54
- References
- 44
- Citations by year
- 2026: 21 · 2025: 22 · 2024: 11
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Scientific Reports (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- ALS Society of Canada (100009017)
- Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada (501100002790)
- Fondation Brain Canada (100009408)
- Gouvernement du Canada | Canadian Institutes of Health Research (501100000024)
- Prime Minister Fellowship Bangladesh
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Computer Science › Artificial Intelligence › Domain Adaptation and Few-Shot Learning
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Keywords
- domain shift, multi-center MRI, structural MRI, combat, image harmonization, disease classification, neuroimaging, deep learning
- MeSH terms
- Machine Learning, Deep Learning, Magnetic Resonance Imaging, Natural Language Processing, Neuroimaging
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.