Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 57 of the 57 references it cites were found in a registry or an index.

Removal of chromium from tannery industry wastewater using iron-based electrocoagulation process: experimental; kinetics; isotherm and economical studies

Open access

Abstract

Chromium is a hazardous compound from industrial processes, known for its toxicity, mutagenicity, teratogenicity, and carcinogenicity. Chemical methods are efficient but cost-effective alternatives with reduced sludge are sought. Electro-coagulation, utilizing low-cost iron plate electrodes, was explored for factual tannery wastewater treatment in this manuscript. Operating parameters such as initial chromium concentration, voltage, electrode number, operating time, agitation speed and current density has been studied to evaluate the treatment effeciency. Under optimal conditions (15 V, 0.4 mA/cm 2, 200 rpm, 330 ppm chromium, 8 iron electrodes with a total surface area of 0.1188 m 2, 3 h), chromium elimination was 98.76%. Iron anode consumption, power use, and operating cost were 0.99 gm/L, 0.0143 kW-h/L, and 160 EGP/kg of chromium eliminated, respectively. Kinetics studies were pursued first-order reaction (97.99% correlation), and Langmuir isotherms exhibited strong conformity (Langmuir R 2: 99.99%). A predictive correlation for chromium elimination (R 2: 97.97%) was developed via statistical regression. At HARBY TANNERY factory in Egypt, industrial sewage treatment achieved a final chromium disposal rate of 98.8% under optimized conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-023-46848-9

Cites

57 of 57 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Schematic diagram of the used system for electro-coagulation.
Figure 1 Schematic diagram of the used system for electro-coagulation.CC BY · PubMed Central
Figure 2 Effect of treatment time on chromium elimination efficiency (6 electrodes, 15 V, 0.4 mA/cm2, 200 rpm and 330 ppm Cr+).
Figure 2 Effect of treatment time on chromium elimination efficiency (6 electrodes, 15 V, 0.4 mA/cm2, 200 rpm and 330 ppm Cr+).CC BY · PubMed Central
Figure 3 Effect of initial chromium concentration on chromium elimination efficiency (6 electrodes, 15 V, 0.4 mA/cm2, 200 rpm and 3 h).
Figure 3 Effect of initial chromium concentration on chromium elimination efficiency (6 electrodes, 15 V, 0.4 mA/cm2, 200 rpm and 3 h).CC BY · PubMed Central
Figure 4 Effect of applied voltage on chromium elimination percentage (6 electrodes, 0.4 mA/cm2, 330 rpm, 330 ppm Cr+ and 3 h).
Figure 4 Effect of applied voltage on chromium elimination percentage (6 electrodes, 0.4 mA/cm2, 330 rpm, 330 ppm Cr+ and 3 h).CC BY · PubMed Central
Figure 5 Effect of current density on chromium elimination percentage (6 electrodes, 15 V, 200 rpm, 330 ppm Cr+ and 3 h).
Figure 5 Effect of current density on chromium elimination percentage (6 electrodes, 15 V, 200 rpm, 330 ppm Cr+ and 3 h).CC BY · PubMed Central
Figure 6 Effect of current density on power consumption and chromium removal % (8 electrodes, 15 V, 200 rpm, 330 ppm Cr+ and 3 h).
Figure 6 Effect of current density on power consumption and chromium removal % (8 electrodes, 15 V, 200 rpm, 330 ppm Cr+ and 3 h).CC BY · PubMed Central
Figure 7 Effect of magnetic agitation velocity on chromium elimination percentage (6 electrodes, 15 V, 0.4 mA/cm2, 330 ppm Cr+ and 3 h).
Figure 7 Effect of magnetic agitation velocity on chromium elimination percentage (6 electrodes, 15 V, 0.4 mA/cm2, 330 ppm Cr+ and 3 h).CC BY · PubMed Central
Figure 8 Effect of number Fe electrodes on chromium elimination percentage at (0.4 mA/cm2,15 V, 200 rpm, 330 ppm Cr+ and 3 h).
Figure 8 Effect of number Fe electrodes on chromium elimination percentage at (0.4 mA/cm2,15 V, 200 rpm, 330 ppm Cr+ and 3 h).CC BY · PubMed Central
Figure 9 Reaction rate of 330 ppm initial chromium concentration at ideal processing factors. a First order kinetic model. b second order kinetic model.
Figure 9 Reaction rate of 330 ppm initial chromium concentration at ideal processing factors. a First order kinetic model. b second order kinetic model.CC BY · PubMed Central
Figure 10 Isothermal models for the chromium adsorption onto carbonized rice straw: a Langmuir isotherm model. b Freundlich isotherm model.
Figure 10 Isothermal models for the chromium adsorption onto carbonized rice straw: a Langmuir isotherm model. b Freundlich isotherm model.CC BY · PubMed Central
Figure 11 Normal probability of standardized errors.
Figure 11 Normal probability of standardized errors.CC BY · PubMed Central
Figure 12 Predicted chromium removal % vs. observed chromium removal %
Figure 12 Predicted chromium removal % vs. observed chromium removal %CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 57 references

Research works printed but not linked: 7

  1. Castiblanco, Y., Perilla, A., Arbelaez, O., Velásquez, P. & Santis, A. Effect of the pH and the catalyst concentration on the removal of hexavalent chromium (Cr (VI)) during photocatalysis of wastewater from plating on plastics industry. Chem. Eng. Trans. 86, 679–684 (2021).
  2. Gonzalez-Delgado, A., Tejada-Tovar, C. & Villabona-Ortiz, A. Computer-aided modeling and evaluation of a packed bed for chromium (vi) removal using residual biomass of Theobroma Cacao L. Chem. Eng. Trans. 92, 517–522 (2022).
  3. Aboutaleb, E., Kamel, G. & Hellal, M. Investigation of effective treatment techniques for olive mill wastewater. Egypt. J. Chem. 61, 415–422 (2018).
  4. Villabona-Ortíz, Á., Tejada-Tovar, C. & Contreras-Amaya, R. Electrocoagulation as an alternative for the removal of chromium (VI) in solution. Tecnura 25, 28–42 (2021). · DOI
  5. Patel, S. R. & Parikh, S. P. Chromium removal from industrial effluent by electrocoagulation: Operating cost and kinetic analysis. J. Environ. Treat. Tech. 9, 621–628 (2021).
  6. Dermentzis, K., Christoforidis, A., Valsamidou, E., Lazaridou, A. & Kokkinos, N. Removal of hexavalent chromium from electroplating wastewater by electrocoagulation with iron electrodes. Glob. Nest J 13, 412–418 (2011).
  7. Nouri, J., Mahvi, A. H. & Bazrafshan, E. Application of electrocoagulation process in removal of zinc and copper from aqueous solutions by aluminum electrodes. Int. J. Environ. Res. 4, 201–208 (2010).

Cited by

See all 53

Metadata

Authors
El-Gawad, H. A., Hassan, G. K., Aboelghait, K. M., Mahmoud, W. H., Mohamed, R. M., & Afify, A. A.
Affiliations
  • El Shorouk Academy (EG)
  • National Research Centre (EG)
  • Cairo University (EG)
  • Suez Canal University (EG)
Corresponding author
Aboelghait, Karim M.
Venue
Scientific Reports
Published
2023-11-10
Volume
13
Issue
1
Pages
19597-19597
ISSN
2045-2322 (ISSN-L)
OpenAlex
W4388567725
Cited by
50
References
57
Citations by year
2026: 17 · 2025: 21 · 2024: 12
FWCI
3.99
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Greater South Information System
Funders
National Research Centre Egypt
Topics
  • Physical Sciences › Environmental Science › Water Science and Technology › Coagulation and Flocculation Studies
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Chromium effects and bioremediation
  • Physical Sciences › Environmental Science › Environmental Engineering › Environmental remediation with nanomaterials
Keywords
chromium removal, tannery wastewater, electrocoagulation, iron electrodes, heavy metal removal, first-order kinetics, Langmuir isotherm, operating costs, current density, wastewater treatment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Removal of chromium from tannery industry wastewater using iron-based electrocoagulation process: experimental; kinetics; isotherm and economical studies. https://app.cochat.ai/papers/10.1038/s41598-023-46848-9
The paper
El-Gawad, H. A., Hassan, G. K., Aboelghait, K. M., Mahmoud, W. H., Mohamed, R. M., & Afify, A. A. (2023). Removal of chromium from tannery industry wastewater using iron-based electrocoagulation process: experimental; kinetics; isotherm and economical studies. Scientific Reports. https://doi.org/10.1038/s41598-023-46848-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.