Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples
Open accessThe DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index; 3 of the 17 sources its claims cite were checked for support.
Abstract
This study aims to develop a dispersive liquid-liquid micro-extraction (DLLME) method for simultaneous determination of triazole fungicides (TFs). A hydrophobic molecular deep eutectic solvent (DES), composed of diphenylamine (DPA) and benzophenone (BZP) in a 1:1 molar ratio, was prepared as an extraction solvent for the adsorption of TFs. The rapid injection of a dispersion solvent containing the extraction solvent (DES) facilitated the extraction process, and phase separation was further accelerated through centrifugation. Under the optimal conditions, the proposed method provided a correlation coefficient greater than 0.993, with intra-day and inter-day RSDs ranging from 2.5% to 4.8% and 5.5% to 7.1%, respectively. The limits of detection and quantitation were found to be in the range of 0.5-1.0 ng mL − 1 and 1.6–3.3 ng mL − 1 , respectively. Enrichment factors ranged from 593 to 1380. Ultimately, the proposed extraction method successfully detected residual TFs, achieving relative recoveries between 84.6% and 109.6% in water, wheat, and rice samples. Furthermore, this study provides comparative insights into the presence of TFs in bran compared to hulled wheat samples. The findings demonstrate that the proposed DLLME method, based on a tailored hydrophobic DPA–BZP-1:1 DES, provides a simple, low-solvent, and selective sample preparation strategy, offering an effective methodological alternative for the routine monitoring of triazole fungicide residues in agricultural products and environmental samples.
Overview
CoChat Summary
TL;DR
This study developed a hydrophobic deep eutectic solvent (DPA:BZP 1:1) dispersive liquid-liquid microextraction method coupled to GC-FID for simultaneous determination of six triazole fungicides in water, wheat, and rice. Under optimized conditions it achieved low detection limits, high enrichment factors, and acceptable recoveries, and compared bran versus hulled wheat for fungicide presence.
Key findings
- The method gave correlation coefficients of 0.993–0.996, intra-day RSDs of 2.5–4.8%, inter-day RSDs of 5.5–7.1%, LODs of 0.5–1.0 ng mL−1, LOQs of 1.6–3.3 ng mL−1, and enrichment factors of 593–1380.
- Relative recoveries in spiked water, wheat, and rice samples were 84.6–109.6%.
- In wheat, hexaconazole and diniconazole passed through the bran and remained in hulled wheat; the bran-versus-hulled-wheat comparison is reported as a first.
- The AGREE greenness score was 0.56; the method uses 25 µL DES plus 1.5 mL methanol, reported as a 90–98% reduction in solvent consumption versus classical LLE.
Methods
- The DES was prepared by mixing diphenylamine and benzophenone in a 1:1 molar ratio, then ultrasonicating at 35 °C for 1 min until a homogeneous yellow eutectic liquid formed.
- DLLME used 50 mL aqueous sample at pH 3.0; 1500 µL methanol containing 25 µL DES was injected rapidly, shaken manually for 1 min, centrifuged at 5000 rpm for 5 min, and 1 µL of the sedimented DES droplet was injected into GC-FID.
- Rice and wheat were obtained from random stores in Tehran, and river water was collected from three Jajrood River locations and combined; wheat bran was removed and hulled wheat analyzed separately, with samples spiked at 20, 100, and 200 ng mL−1. Validation covered linearity from 1.6 to 1000 ng mL−1, LOD/LOQ, RSDs, enrichment factors, and relative recovery.
Limitations
- Stated: the extraction solvent is not recyclable, and direct injection of DES into the GC system limits solvent recyclability; future immobilization on magnetic nanoparticles could improve greenness.
- Stated: the AGREE score of 0.56 is acceptable but not optimal, and greenness could be improved in future studies.
- Evident: validation and application are limited to six triazole fungicides and wheat, rice, and river water samples; no mass-spectrometric confirmation or broader matrix/analyte coverage is reported in the text.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures



Verification
Claims the paper makes
1 Valid · 1 Not valid · 3 Not checked · 43 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“Hence, 1500 µL methanol (25 µL DES) was selected as the optimal dispersion solvent31.”
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Results and discussion > Optimization of the extraction process
What the sources say
- Disputedcites [31] Kachangoon, R., Vichapong, J., Santaladchaiyakit, Y. & Teshima, N. Trace-Level Determination of Triazole Fungicides Using Effervescence-Assisted Liquid–Liquid Microextraction Based on Ternary Deep Eutectic Solvent Prior to High-Performance Liquid Chromatography. ACS Omega. 8, 21332–21340 (2023). sourceExperimental — accuracy not yet measured
The Results and Discussion section on extraction-condition optimization selects 100 μL of TDES as the extracting solvent, not 25 μL of DES. Its solvent optimization selects acetonitrile rather than methanol; the Experimental Section says dispersion was produced by carbon dioxide bubbles, not by 1500 μL of methanol. No page numbers are available in our copy. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“However, the present method indicates superior performance regarding EFs compared to most reported methods16,30,31,37–43.”
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Results and discussion > Analysis of the wheat, rice and river water samples
What the sources say
- Not checked — no full text of the sourcecites [16] Jing, X. et al. Evaporation-assisted dispersive liquid–liquid microextraction based on the solidification of floating organic droplets for the determination of triazole fungicides in water samples by high-performance liquid chromatography. J. Chromatogr. A. 1597, 46–53 (2019). source
- Partly supportedcites [30] Bosco, C., Mariani, F. & Gentili, A. Hydrophobic Eutectic Solvent-Based Dispersive Liquid-Liquid Microextraction Applied to the Analysis of Pesticides in Wine. Molecules 27, 908 (2022). sourceExperimental — accuracy not yet measured
Section 2.3 (page unavailable) reports enrichment factors of 43–86 for the cited paper’s method, providing a benchmark for comparison. Section 2.4 compares other performance measures with a few methods, but does not establish that the citing paper’s “present method” has superior EFs to most reported methods. (LLM, conf=0.78)
- Partly supportedcites [31] Kachangoon, R., Vichapong, J., Santaladchaiyakit, Y. & Teshima, N. Trace-Level Determination of Triazole Fungicides Using Effervescence-Assisted Liquid–Liquid Microextraction Based on Ternary Deep Eutectic Solvent Prior to High-Performance Liquid Chromatography. ACS Omega. 8, 21332–21340 (2023). sourceExperimental — accuracy not yet measured
Analytical Performance and Method Validation (page unavailable) reports enrichment factors of 112–142 for the cited method. The Comparison of the Proposed Method with Other Previously Reported Methods section calls its EF high, but Table 3 gives no EFs for the other methods. This source therefore supplies a reported EF for comparison, not evidence that the citing paper’s method outperforms most reported methods on EF. (LLM, conf=0.78)
- Not checked — no full text of the sourcecites [37] Farajzadeh, M. A., Djozan, D. & Khorram, P. Development of a new dispersive liquid-liquid microextraction method in a narrow-bore tube for preconcentration of triazole pesticides from aqueous samples. Anal. Chim. Acta. 713, 70–78 (2012). source
- Not checked — no full text of the sourcecites [38] Zhang, Y., Zhang, Y., Zhao, Q., Chen, W. & Jiao, B. Vortex-Assisted Ionic Liquid Dispersive Liquid-Liquid Microextraction Coupled with High-Performance Liquid Chromatography for the Determination of Triazole Fungicides in Fruit Juices. Food Anal. Methods. 9, 596–604 (2016). source
- Not checked — no full text of the sourcecites [39] Wang, H. et al. Detection of triazole pesticides in environmental water and juice samples using dispersive liquid-liquid microextraction with solidified sedimentary ionic liquids. New. J. Chem. 40, 4696–4704 (2016). source
- Not checked — no full text of the sourcecites [40] Kadivar, M. & Aliakbar, A. A new composite based on graphene oxide-poly 3-aminophenol for solid- phase microextraction of four triazole fungicides in water and fruit juices prior to high-performance liquid chromatography analysis. Food Chem. 299, 125127 (2019). source
- Not checked — no full text of the sourcecites [41] Aladaghlo, Z., Fakhari, A. R., Alavioon, S. I. & Dabiri, M. Ultrasound assisted dispersive solid phase extraction of triazole fungicides by using an N-heterocyclic carbene copper complex supported on ionic liquid-modified graphene oxide as a sorbent. Microchim Acta 186, (2019). source
- Not checked — no full text of the sourcecites [42] Aladaghlo, Z., Javanbakht, S., Sahragard, A., Reza Fakhari, A. & Shaabani, A. Cellulose-based nanocomposite for ultrasonic assisted dispersive solid phase microextraction of triazole fungicides from water, fruits, and vegetables samples. Food Chem. 403, 134273 (2023). source
- Not checked — no full text of the sourcecites [43] Wei, Q. et al. Tablet-effervescence-assisted dissolved carbon flotation for the extraction of four triazole fungicides in water by gas chromatography with mass spectrometry. J. Sep. Sci. 39, 4603–4609 (2016). source
hedged- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Investigating the effects on TFs extraction efficiencies from pH 2.0 to 8.0 indicated that efficiencies increased with rising pH from 2.0 to 3.0 (Fig. S1).”
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Results and discussion > Optimization of the extraction process
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Notably, the developed method shows LODs and RSDs similar to those of previous studies.”
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Results and discussion > Analysis of the wheat, rice and river water samples
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Limits of quantitation (LOQs), calculated at the S/N = 10, were in the range of 1.6 to 3.3 ng mL− 1.”
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Results and discussion > Method validation
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
24 more claims
Create a free account to see all 48 claims and every source verdict.
- It may state two separate claims as one. 16
- Probably not a substantial claim. 5
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Introduction
“eliminating the need for dispersers or auxiliary devices”
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Experimental > DES-DLLME procedure
“1500 µL of dispersion solvent (methanol) containing 25 µL of extraction solvent (DES) was injected quickly”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Conclusion
“relatively low RSDs (< 7.1%)”
§ Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples > Results and discussion > Method validation
“5.5 to 7.1% for inter-day (n = 5 × 3 days)”
Citations
Cites
AGREE—Analytical GREEnness Metric Approach and Software
Pena-Pereira, F., Wojnowski, W., & Tobiszewski, M. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c01887 · Cited by 3,983
Physicochemical properties of deep eutectic solvents: A review
Omar, K. A., & Sadeghi, R. (2022) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2022.119524 · Cited by 521 · cited 1×
“Consequently, extraction efficiency decreases above the optimal pH 35,36 .”
Assessing the toxicity and biodegradability of deep eutectic solvents
Wen, Q., Chen, J.-X., Tang, Y.-L., Wang, J., & Yang, Z. (2015) · Chemosphere · doi:10.1016/j.chemosphere.2015.02.061 · Cited by 480 · cited 2×
“Compared to other tested pesticide classes, these interactions were found to be more pronounced for triazole compounds, resulting in rapid and efficient partitioning of the target analytes into the DES phase, even at a low extraction solvent volume 28,29,32 .”
Ilharco, L. M., Garcia, A. R., Lopes da Silva, J., & Vieira Ferreira, L. F. (1997) · Langmuir · doi:10.1021/la962138u · Cited by 137 · cited 1×
“Importantly, these spectral changes fully agree with the interaction patterns previously reported for this DES system in the literature 29,34 , confirming that the DES synthesized in this work exhibits the same hydrogen-bonding and non-covalent assembly characteristics.”
Chen, Y., & Yu, Z. (2023) · Green Chemical Engineering · doi:10.1016/j.gce.2023.11.001 · Cited by 134
Airouyuwa, J. O., Sivapragasam, N., Redha, A. A., & Maqsood, S. (2024) · Food Chemistry · doi:10.1016/j.foodchem.2024.139061 · Cited by 132 · cited 2×
“A different class of solvents called deep eutectic solvents (DESs), are formed by harmonious blends of two solids acting as hydrogen bond donor (HBD) and acceptor (HBA) 21,22 .”
Farajzadeh, M. A., Djozan, D., & Khorram, P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.11.030 · Cited by 89 · cited 1×
“However, the present method indicates superior performance regarding EFs compared to most reported methods 16,30,31,37–43 .”
Liu, G., Tian, M., Lu, M., Shi, W., Li, L., Gao, Y., Li, T., & Xu, D. (2021) · Journal of Chromatography B · doi:10.1016/j.jchromb.2020.122500 · Cited by 89
Jalbani, N. B., & Soylak, M. (2014) · Food Chemistry · doi:10.1016/j.foodchem.2014.07.015 · Cited by 76 · cited 1×
“Extensive attention has been attributed to ionic liquids (ILs) as a versatile solvent class, which includes advantageous features like low melting points, exceptionally low vapor pressures, high thermal stability, and customizable molecular properties 19,20 .”
Tüzen, M., Uluözlü, Ö. D., Mendil, D., Soylak, M., Machado, L. O. R., dos Santos, W. N. L., & Ferreira, S. L. C. (2017) · Food Chemistry · doi:10.1016/j.foodchem.2017.10.115 · Cited by 67 · cited 1×
“Extensive attention has been attributed to ionic liquids (ILs) as a versatile solvent class, which includes advantageous features like low melting points, exceptionally low vapor pressures, high thermal stability, and customizable molecular properties 19,20 .”
Cited by
Samanpong, N., Rattakham, K., Wongsaipun, S., Dubey, M., & Chaiyasith, W. C. (2026) · Food Analytical Methods · doi:10.1007/s12161-026-03282-7
“Recent developments in dispersive liquid–liquid microextraction, including hydrophobic deep eutectic solvent systems, further demonstrate the potential of liquid-phase dispersion for rapid and low-solvent sample preparation (Fatemi et al. 2026).”
Samanpong, N., Putkham, A. I., Wongsaipun, S., Janrungroatsakul, W., Sirikulkajorn, A., Dubey, M., & Chaiyasith, W. C. (2026) · Food Analytical Methods · doi:10.1007/s12161-026-03313-3
“(Fatemi et al. 2026).”
Metadata
- Authors
- Fatemi, F. S., Shahsavani, A., Aladaghlo, Z., & Fakhari, A. R.
- Affiliations
- Shahid Beheshti University (IR)
- University of Tehran (IR)
- Corresponding author
- Fakhari, Ali Reza
- Venue
- Scientific Reports
- Published
- 2026-05-06
- Volume
- 16
- Issue
- 1
- ISSN
- 2045-2322 (ISSN-L)
- PMC
- PMC13338161
- OpenAlex
- W7160372687
- Cited by
- 2
- References
- 44
- Citations by year
- 2026: 2
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by-nc-nd
- creativecommons.org/licenses/by-nc-nd/4.0 (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0 (vor, 62 d)
- Locations
- Scientific Reports (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
- Physical Sciences › Chemistry › Physical and Theoretical Chemistry › Ionic liquids properties and applications
- Keywords
- triazole fungicides, deep eutectic solvents, dispersive liquid-liquid microextraction, pesticide residues, grain contamination, wheat, rice, water samples, diphenylamine, benzophenone, residue monitoring, sample preparation
- MeSH terms
- Deep Eutectic Solvents, Edible Grain, Fungicides, Industrial, Oryza, Solvents, Triazoles, Water, Water Pollutants, Chemical, Triticum, Hydrophobic and Hydrophilic Interactions, Liquid Phase Microextraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples. https://app.cochat.ai/papers/10.1038/s41598-026-51500-3
- The paper
- Fatemi, F. S., Shahsavani, A., Aladaghlo, Z., & Fakhari, A. R. (2026). Hydrophobic deep eutectic solvent-based DLLME for simultaneous determination of triazole fungicides in grain and water samples. Scientific Reports. https://doi.org/10.1038/s41598-026-51500-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.