Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 172

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Wearable activity monitors to assess performance status and predict clinical outcomes in advanced cancer patients

Open access
Gresham, Gillian, Hendifar, Andrew E., Spiegel, Brennan, Neeman, Elad, Tuli, Richard, Rimel, B. J., Figlin, Robert A., Meinert, Curtis L., Piantadosi, Steven, Shinde, Arvind M. · 2018 · npj Digital Medicine

Abstract

An objective evaluation of patient performance status (PS) is difficult because patients spend the majority of their time outside of the clinic, self-report to providers, and undergo dynamic changes throughout their treatment experience. Real-time, objective activity data may allow for a more accurate assessment of PS and physical function, while reducing the subjectivity and bias associated with current assessments. Consenting patients with advanced cancer wore a wearble activity monitor for three consecutive visits in a prospective, single-cohort clinical trial. Provider-assessed PS (ECOG/Karnofsky) and NIH PROMIS® patient-reported outcomes (PROs) were assessed at each visit. Associations between wearable activity monitor metrics (steps, distance, stairs) and PS, clinical outcomes (adverse events, hospitalizations, survival), and PROs were assessed using correlation statistics and in multivariable logistic regression models. Thirty-seven patients were evaluated (54% male, median 62 years). Patients averaged 3700 steps, 1.7 miles, and 3 flights of stairs per day. Highest correlations were observed between average daily steps and ECOG-PS and KPS (r = 0.63 and r = 0.69, respectively p < 0.01). Each 1000 steps/day increase was associated with reduced odds for adverse events (OR: 0.34, 95% CI 0.13, 0.94), hospitalizations (OR: 0.21 95% CI 0.56, 0.79), and hazard for death (HR: 0.48 95% CI 0.28–0.83). Significant correlations were also observed between activity metrics and PROs. Our trial demonstrates the feasibility of using wearable activity monitors to assess PS in advanced cancer patients and suggests their potential use to predict clinical and patient-reported outcomes. These findings should be validated in larger, randomized trials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-018-0032-6

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 172

Metadata

Authors
Gresham, G., Hendifar, A. E., Spiegel, B., Neeman, E., Tuli, R., Rimel, B. J., Figlin, R. A., Meinert, C. L., Piantadosi, S., & Shinde, A. M.
Venue
npj Digital Medicine
Published
2018-07-05
Volume
1
Issue
1
Pages
27-27
ISSN
2398-6352 (ISSN-L)
OpenAlex
W2808816741
Cited by
172
References
8
FWCI
5.39
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wearable activity monitors to assess performance status and predict clinical outcomes in advanced cancer patients. https://app.cochat.ai/papers/10.1038/s41746-018-0032-6
The paper
Gresham, G., Hendifar, A. E., Spiegel, B., Neeman, E., Tuli, R., Rimel, B. J., Figlin, R. A., Meinert, C. L., Piantadosi, S., & Shinde, A. M. (2018). Wearable activity monitors to assess performance status and predict clinical outcomes in advanced cancer patients. npj Digital Medicine. https://doi.org/10.1038/s41746-018-0032-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.