Human-in-the-loop (HITL) AI may enable an ideal symbiosis of human experts and AI models, harnessing the advantages of both while at the same time overcoming their respective limitations. The purpose of this study was to investigate a novel collective intelligence technology designed to amplify the diagnostic accuracy of networked human groups by forming real-time systems modeled on biological swarms. Using small groups of radiologists, the swarm-based technology was applied to the diagnosis of pneumonia on chest radiographs and compared against human experts alone, as well as two state-of-the-art deep learning AI models. Our work demonstrates that both the swarm-based technology and deep-learning technology achieved superior diagnostic accuracy than the human experts alone. Our work further demonstrates that when used in combination, the swarm-based technology and deep-learning technology outperformed either method alone. The superior diagnostic accuracy of the combined HITL AI solution compared to radiologists and AI alone has broad implications for the surging clinical AI deployment and implementation strategies in future practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41746-019-0189-7

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Bootstrapped average AUC curves. AUC curves show that the swarms (blue bars) outperform group A (left image), group B (middle image), and combined group (right image). Radiologists (orange bars) performances in diagnosing pneumonia. Swarm also outperforms CheXNet (green bars).
Fig. 1 Bootstrapped average AUC curves. AUC curves show that the swarms (blue bars) outperform group A (left image), group B (middle image), and combined group (right image). Radiologists (orange bars) performances in diagnosing pneumonia. Swarm also outperforms CheXNet (green bars).CC BY · PubMed Central
Fig. 2 Scatterplot of swarm vs. CheXMax probabilistic diagnoses, with cases colored by ground truth. The scatterplots show that CheXMax and human swarms assign very different probabilities to each case (left image). The gray “Augmented Cases” range shows cases that were sent from CheXMax to the Swarm for augmentation. CheXMax has a high incidence of True Positives (blue-colored cases below the horizontal CheXMax Threshold line), but when the CheXMax gives a weak positive diagnosis (between 0.04008 and 0.055 on the y-axis), it is often incorrect (11 out of 15 cases correct, or an accuracy of 73%). Using a human swarm to re-classify these weak positive cases results in correctly labeling 14 out of 15 of the cases—an accuracy improvement of 20%. The cases on which the two diagnostic methods disagreed are more clearly visualized in the scatterplot of diagnostic disagreement (right image).
Fig. 2 Scatterplot of swarm vs. CheXMax probabilistic diagnoses, with cases colored by ground truth. The scatterplots show that CheXMax and human swarms assign very different probabilities to each case (left image). The gray “Augmented Cases” range shows cases that were sent from CheXMax to the Swarm for augmentation. CheXMax has a high incidence of True Positives (blue-colored cases below the horizontal CheXMax Threshold line), but when the CheXMax gives a weak positive diagnosis (between 0.04008 and 0.055 on the y-axis), it is often incorrect (11 out of 15 cases correct, or an accuracy of 73%). Using a human swarm to re-classify these weak positive cases results in correctly labeling 14 out of 15 of the cases—an accuracy improvement of 20%. The cases on which the two diagnostic methods disagreed are more clearly visualized in the scatterplot of diagnostic disagreement (right image).CC BY · PubMed Central
Fig. 3 Case examples. Each of the three rows a–c represent three different patients. Grayscale image is on the left with the corresponding class activation map to its right. The top row example a includes a patient with pneumonia in the left lung, correctly predicted by CheXMax but incorrectly by swarm. The middle row b is an example of a patient with metastatic disease but without pneumonia, correctly predicted by swarm and incorrectly by CheXMax. The bottom row c is an example of an augmented case, where CheXMax provided a low confidence positive prediction (p = 0.41) but was correctly predicted as negative by swarm.
Fig. 3 Case examples. Each of the three rows a–c represent three different patients. Grayscale image is on the left with the corresponding class activation map to its right. The top row example a includes a patient with pneumonia in the left lung, correctly predicted by CheXMax but incorrectly by swarm. The middle row b is an example of a patient with metastatic disease but without pneumonia, correctly predicted by swarm and incorrectly by CheXMax. The bottom row c is an example of an augmented case, where CheXMax provided a low confidence positive prediction (p = 0.41) but was correctly predicted as negative by swarm.CC BY · PubMed Central
Fig. 4 Sensitivity analysis of augmented model accuracy. The shape of the average accuracy line shows a consistent increase in the accuracy of the augmented model when the 0–14% lowest-confidence cases are sent to the swarm, from 82% correct of CheXMax (sending 0% of cases) to 90% correct when sending the 14% of lowest-confidence positive and negative cases to the swarm. The model performs similarly when 16–32% of cases are sent to the swarm, achieving between 88% and 92% accuracy across this sensitivity range. If more than 32% of cases are sent to the swarm, the accuracy of the system decreases, until the limit of sending all diagnoses to the swarm is reached (100% of cases swarmed), where the accuracy returns to the swarm score of 84%.
Fig. 4 Sensitivity analysis of augmented model accuracy. The shape of the average accuracy line shows a consistent increase in the accuracy of the augmented model when the 0–14% lowest-confidence cases are sent to the swarm, from 82% correct of CheXMax (sending 0% of cases) to 90% correct when sending the 14% of lowest-confidence positive and negative cases to the swarm. The model performs similarly when 16–32% of cases are sent to the swarm, achieving between 88% and 92% accuracy across this sensitivity range. If more than 32% of cases are sent to the swarm, the accuracy of the system decreases, until the limit of sending all diagnoses to the swarm is reached (100% of cases swarmed), where the accuracy returns to the swarm score of 84%.CC BY · PubMed Central
Fig. 5 Sensitivity analysis of accuracy increase relative to CheXMax. Sensitivity analysis shows a band between 6% and 34%, where the 90% confidence interval is only ever >0%. This indicates that when sending between 6% and 34% of the lowest-confidence cases to the swarm using this method, there is high confidence that the augmented model would diagnose the cases more accurately than the CheXMax alone. If the range is limited between 14% and 28%, the average improvement in accuracy is 7.75% correct.
Fig. 5 Sensitivity analysis of accuracy increase relative to CheXMax. Sensitivity analysis shows a band between 6% and 34%, where the 90% confidence interval is only ever >0%. This indicates that when sending between 6% and 34% of the lowest-confidence cases to the swarm using this method, there is high confidence that the augmented model would diagnose the cases more accurately than the CheXMax alone. If the range is limited between 14% and 28%, the average improvement in accuracy is 7.75% correct.CC BY · PubMed Central
Fig. 6 Bootstrapped average specificity and sensitivity of aggregate diagnostic methods. The bootstrapped specificity histograms show that the swarms in the combined group (blue bars) outperform CheXMax (green bars) in terms of specificity (left image), but CheXMax outperforms the swarms in terms of sensitivity (right image). The HITL Combined model combines the best of both the CheXMax and swarm diagnostic methods, by attaining swarm-level specificity and CheXMax-level sensitivity.
Fig. 6 Bootstrapped average specificity and sensitivity of aggregate diagnostic methods. The bootstrapped specificity histograms show that the swarms in the combined group (blue bars) outperform CheXMax (green bars) in terms of specificity (left image), but CheXMax outperforms the swarms in terms of sensitivity (right image). The HITL Combined model combines the best of both the CheXMax and swarm diagnostic methods, by attaining swarm-level specificity and CheXMax-level sensitivity.CC BY · PubMed Central
Fig. 7 Swarm platform. A system diagram (left image) of the Swarm platform shows the connection of networked human users. A Swarm engine algorithm received continuous input from the humans as they are making their decision and provides real-time collaborative feedback back to the humans to create a dynamic feedback loop. Swarm Platform positioned next to a second screen for viewing radiograph (middle image). A snapshot (right image) of the real-time swarm of six radiologists (group B) shows small magnets controlled by radiologists pulling on the circular puck in the process of collectively converging towards a probability of pneumonia. To view a video of the above question being answered in the Swarm platform, visit the following link: https://unanimous.ai/wp-content/uploads/2019/05/Radiology-Swarm.gif.
Fig. 7 Swarm platform. A system diagram (left image) of the Swarm platform shows the connection of networked human users. A Swarm engine algorithm received continuous input from the humans as they are making their decision and provides real-time collaborative feedback back to the humans to create a dynamic feedback loop. Swarm Platform positioned next to a second screen for viewing radiograph (middle image). A snapshot (right image) of the real-time swarm of six radiologists (group B) shows small magnets controlled by radiologists pulling on the circular puck in the process of collectively converging towards a probability of pneumonia. To view a video of the above question being answered in the Swarm platform, visit the following link: https://unanimous.ai/wp-content/uploads/2019/05/Radiology-Swarm.gif.CC BY · PubMed Central
Fig. 8 Support density visualization. In this support density visualization corresponding to the swarm in Fig. 1, the puck’s trajectory is shown as a white dotted line, and the distribution of force over the hex is plotted as a Gaussian kernel density heatmap. Notice that this swarm was split between the “5–25%” and “0–5%” bins, and more force was directed towards the 5–25%. This aggregate behavior is reflected in the swarm’s interpolated diagnosis of 11.1%.
Fig. 8 Support density visualization. In this support density visualization corresponding to the swarm in Fig. 1, the puck’s trajectory is shown as a white dotted line, and the distribution of force over the hex is plotted as a Gaussian kernel density heatmap. Notice that this swarm was split between the “5–25%” and “0–5%” bins, and more force was directed towards the 5–25%. This aggregate behavior is reflected in the swarm’s interpolated diagnosis of 11.1%.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 48 references

Cited by

See all 254

Metadata

Authors
Patel, B. N., Rosenberg, L., Willcox, G., Baltaxe, D., Lyons, M., Irvin, J., Rajpurkar, P., Amrhein, T., Gupta, R., Halabi, S., Langlotz, C., Lo, E., Mammarappallil, J., Mariano, A. J., Riley, G., Seekins, J., Shen, L., Zucker, E., & Lungren, M. P.
Affiliations
  • Stanford Medicine (US)
  • Unanimous AI (United States) (US)
  • Duke Medical Center (US)
Corresponding author
Patel, Bhavik N.
Venue
npj Digital Medicine
Published
2019-11-18
Volume
2
Issue
1
Pages
111-111
ISSN
2398-6352 (ISSN-L)
OpenAlex
W2984904339
Cited by
254
References
48
Citations by year
2026: 26 · 2025: 44 · 2024: 32 · 2023: 33 · 2022: 43 · 2021: 42 · 2020: 33 · 2019: 1
FWCI
9.45
Type
journal article
Language
en
Open access
Licence
Locations
  • npj Digital Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Topics
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › COVID-19 diagnosis using AI
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
Keywords
human-in-the-loop AI, human-machine collaboration, collective intelligence, swarm intelligence, pneumonia diagnosis, chest radiograph, deep learning, diagnostic accuracy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human–machine partnership with artificial intelligence for chest radiograph diagnosis. https://app.cochat.ai/papers/10.1038/s41746-019-0189-7
The paper
Patel, B. N., Rosenberg, L., Willcox, G., Baltaxe, D., Lyons, M., Irvin, J., Rajpurkar, P., Amrhein, T., Gupta, R., Halabi, S., Langlotz, C., Lo, E., Mammarappallil, J., Mariano, A. J., Riley, G., Seekins, J., Shen, L., Zucker, E., & Lungren, M. P. (2019). Human–machine partnership with artificial intelligence for chest radiograph diagnosis. npj Digital Medicine. https://doi.org/10.1038/s41746-019-0189-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.