A human pilot trial of ingestible electronic capsules capable of sensing different gases in the gut
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The use of genetically engineered bacterial strains to assess the gut environment, release metabolites of interest at specific locations within the GI tract, and optimize drug metabolism appears to be on the horizon190, 191.”
From The gut Microbiome in adult and pediatric functional gastrointestinal disorders (2019) · cites this paper as [190]
In the citing paper
“Indeed, this is already partially functional in this regard because the detection of hydrogen signals can be used as a proxy for regional fermentation patterns (Fig. 7).”
From Gut reactions: Breaking down xenobiotic–microbiome interactions (2019) · cites this paper as Kalantar-Zadeh et al., 2018
Citations
Cites
Diet rapidly and reproducibly alters the human gut microbiome
David, L. A., Maurice, C. F., Carmody, R. N., Gootenberg, D. B., Button, J. E., Wolfe, B. E., Ling, A. V., Devlin, A. S., Varma, Y., Fischbach, M. A., et al. (2014) · Nature · doi:10.1038/nature12820 · Cited by 10,100
Dietary Modulation of the Human Colonic Microbiota: Introducing the Concept of Prebiotics
Gibson, G. R., & Roberfroid, M. B. (1995) · The Journal of Nutrition · doi:10.1093/jn/125.6.1401 · Cited by 7,667
A standardised static in vitro digestion method suitable for food – an international consensus
Minekus, M., Alminger, M., Alvito, P., Ballance, S., Bohn, T., Bourlieu, C., Carrière, F., Boutrou, R., Corredig, M., Dupont, D., et al. (2014) · Food Funct. · doi:10.1039/c3fo60702j · Cited by 5,824
Host-gut microbiota metabolic interactions
Nicholson, J. K., Holmes, E., Kinross, J., Burcelin, R., Gibson, G., Jia, W., & Pettersson, S. (2012) · Science · doi:10.1126/science.1223813 · Cited by 4,760
Gut flora in health and disease
Guarner, F., & Malagelada, J.-R. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12489-0 · Cited by 3,365
Conduction Model of Metal Oxide Gas Sensors
Barsan, N., & Weimar, U. (2001) · Journal of Electroceramics · doi:10.1023/a:1014405811371 · Cited by 2,721
Dietary modulation of the human colonic microbiota: updating the concept of prebiotics
Gibson, G. R., Probert, H. M., Loo, J. V., Rastall, R. A., & Roberfroid, M. B. (2004) · Nutrition Research Reviews · doi:10.1079/nrr200479 · Cited by 2,536
Oxidative Stress: An Essential Factor in the Pathogenesis of Gastrointestinal Mucosal Diseases
Bhattacharyya, A., Chattopadhyay, R., Mitra, S., & Crowe, S. E. (2014) · Physiological Reviews · doi:10.1152/physrev.00040.2012 · Cited by 2,484
Inflammasome-mediated dysbiosis regulates progression of NAFLD and obesity
Henao-Mejia, J., Elinav, E., Jin, C., Hao, L., Mehal, W. Z., Strowig, T., Thaiss, C. A., Kau, A. L., Eisenbarth, S. C., Jurczak, M. J., et al. (2012) · Nature · doi:10.1038/nature10809 · Cited by 2,435
Prebiotic effects: metabolic and health benefits
Roberfroid, M., Gibson, G. R., Hoyles, L., McCartney, A. L., Rastall, R., Rowland, I., Wolvers, D., Watzl, B., Szajewska, H., Stahl, B., et al. (2010) · British Journal of Nutrition · doi:10.1017/s0007114510003363 · Cited by 2,085
Research works printed but not linked: 1
- Bermak, A., Belhouari, S. B., Shi, M. & Martinez, D. in Encyclopedia of Sensors Vol. 10 (eds C. A. Grimes, E. C. Dickey, & M. V. Pishko) 1-17 (American Scientifc Publishers, 2006).
Cited by
Items 201–300 of 359
Analysis of Cr/Au contact reliability in embedded poly-Si micro-heater for FET-type gas sensor
Park, J., Jung, G., Hong, S., Jeong, Y., Shin, W., Kim, D., Lee, C., & Lee, J. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.131673 · Cited by 13
Smith, D. A., Jheeta, S., Fuentes, H. V., & Palacios-Pérez, M. (2022) · Life · doi:10.3390/life12081197 · Cited by 15
“Therefore, diverse types of pill-like devices bearing detectors and transmitters have been designed for numerous applications, such as: imaging, measuring pH or temperature, medication monitoring or with a drug reservoir, receiving acoustic data and transforming it to vital sign monitoring [137,138], for luminescence-…”
BackgroundFukada, K., Tajima, T., & Seyama, M. (2022) · Advanced Materials Technologies · doi:10.1002/admt.202200830 · Cited by 13
Precision microbial regulation: Strategies for modulating GIT microbiota for host health
Pei, Z., Li, Q., Zhang, Y., Guo, C., Abdelsattar, M. M., & Bi, Y. (2025) · iMetaOmics. · doi:10.1002/imo2.54 · Cited by 12
“Ingestible electronic capsules could sense O 2 , H 2 , and CO 2 , aiding in the assessment of diet rationality [24].”
Kalantar‐Zadeh, K., Susic, D. F., & Hyett, J. A. (2024) · ACS Sensors · doi:10.1021/acssensors.4c00567 · Cited by 12
Self-citationMicrosensor Based on Gold Nanoparticles for Fast and Sensitive Ortho-Xylene Detection
Li, P., Xia, H., Dai, Y., Yang, H., & Liu, T. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3002379 · Cited by 12
“self-powered sensor system and wearable device [16]–[18].”
Zhu, C., Hong, L., Yang, H., & Sengupta, K. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3216455 · Cited by 11
“3216455 biomolecular assays which require sensitivity on the order of pM, remain a “holy grail” in bioelectronics [4], [5], [6].”
Background3D gas mapping in the gut with AI-enabled ingestible and wearable electronics
Abdigazy, A., Arfan, M., Shao, J., Islam, M. S., Hassan, M. F., & Khan, Y. (2024) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2024.101990 · Cited by 11
“2 Even though this method does not require any external elements, it can only show in which organ the capsule is located at a particular moment.”
Nam, J., Lee, Y., Lee, S., Choi, H., Lee, S. Y., & Yang, D. (2025) · Biotechnology Advances · doi:10.1016/j.biotechadv.2025.108782 · Cited by 14
Advanced electronic noses for future robotic olfaction
Zhang, W., Tang, W., Wan, Z., & Fan, Z. (2026) · npj Robotics · doi:10.1038/s44182-025-00071-y · Cited by 19
Headset bio-sniffer with wireless CMOS camera for percutaneous ethanol vapor from the ear canal
Arakawa, T., Ishikawa, R., Iitani, K., Toma, K., Iwasaki, Y., & Mitsubayashi, K. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100169 · Cited by 14
Goodman, G. R., Vaz, C., Albrechta, H., Boyer, E. W., Mayer, K. H., O’Cleirigh, C. M., & Chai, P. R. (2022) · Current HIV/AIDS Reports · doi:10.1007/s11904-022-00625-x · Cited by 11
Zhang, J., Balakrishnan, G., Srinidhi, S., Bhat, A., Kumar, S., & Bettinger, C. J. (2022) · ACM Conference on Embedded Networked Sensor Systems (SenSys) · doi:10.1145/3560905.3568523 · Cited by 14
“For instance, there have been multiple proposed designs for ingestible capsules to measure internal body temperature [13, 63, 64], pH [16, 32], gastrointestinal pressures [6, 20, 54, 65], and gas and biomolecular sensing [42, 62, 96].”
BackgroundIngestible Smart Capsules for Chemical Sensing in the Gut
Siavashani, A. G., Rehan, M., Travaš‐Sejdić, J., Thomas, D. G., Diller, E., Stine, J. M., Reza Ghodssi, A., & Avci, E. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c04683 · Cited by 11
Development of innovative tools for investigation of nutrient-gut interaction
Huang, W., Xie, C., Young, R. L., Zhao, J., Ebendorff‐Heidepriem, H., Jones, K. L., Rayner, C. K., & Wu, T. (2020) · World Journal of Gastroenterology · doi:10.3748/wjg.v26.i25.3562 · Cited by 12
The final fate of food: On the establishment of in vitro colon models
Hernalsteens, S., Huang, S., Cong, H. H., & Chen, X. D. (2021) · Food Research International · doi:10.1016/j.foodres.2021.110743 · Cited by 11
Application of Sensing Devices in the Detection of Oral, Pulmonary, and Gastrointestinal Diseases
Yu, W., Mou, S., Zhang, X., Sun, J., Xue, Y., Xiong, H., Hsia, K. J., Wan, H., & Wang, P. (2024) · Chemosensors · doi:10.3390/chemosensors12040057 · Cited by 10
Ultrasound assessment of gastrointestinal luminal contents: a narrative review
Su, H. Y., Taylor, K. M., Friedman, A. B., Cataletti, G., & Maconi, G. (2024) · Journal of Ultrasound · doi:10.1007/s40477-024-00951-3 · Cited by 10
“In a recent pilot study of gas sensing capsules, ultrasound was used to confirm the location of the capsule as it progressed through the gastro-intestinal tract [98].”
MethodSelf-citationQuantum Dots-Sensitized High Electron Mobility Transistor (HEMT) for Sensitive NO2 Detection
Hu, Z., Zhou, L., Li, L., Ying, B., Zhao, Y., Wang, P., Li, H., Zhang, Y., & Liu, H. (2023) · Chemosensors · doi:10.3390/chemosensors11040252 · Cited by 10
“Chemiresistive gas sensors are promising for use in a wide range of applications, such as urban air quality monitoring [1], public security [2], and exhaled breath analysis [3–5].”
BackgroundLee, J., Heo, P. W., & Kim, T. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.09.071 · Cited by 10
Cherkasov, N., Baldwin, S., Gibbons, G. J., & Isakov, D. (2020) · ACS Sensors · doi:10.1021/acssensors.0c00720 · Cited by 10
Kataria, P., Gupta, R. K., Gupta, A. K., Kaur, R., Sharma, M., Jha, A. K., Naik, B., Kumar, V., Tavassoli, M., & Kaur, S. (2025) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2025.104880 · Cited by 10
Zheng, T., Kang, N., Lee, C. H. T., & Shao, L. (2025) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2025.3531149 · Cited by 10
“Among these, capsule endoscopy is known for its revolutionary gastrointestinal diagnostic and therapeutic potential [6], [7], [8].”
InfluentialAmmonia Dynamics in the Human Body: Insights in Biomedical Sensing Technologies
Nijkoops, A., Ciocca, M., Angeli, M. A. C., Pogliaghi, S., Krik, S., Avancini, E., Munzenrieder, N. S., Lugli, P., & Petti, L. (2025) · Advanced Sensor Research · doi:10.1002/adsr.202400179 · Cited by 11
Bioelectric and physicochemical foundations of bioelectronics in tissue regeneration
Zheng, Y., Yang, G., Li, P., & Tian, B. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123385 · Cited by 10
Ignored roles of gases in digestive diseases
Zhao, C., Liu, R., Zhou, Y., Zheng, R., Shen, Y., Wen, B., Zhang, B., & Che, J. (2023) · Biomedical Technology · doi:10.1016/j.bmt.2022.11.014 · Cited by 11
A smart nanopaper sensor for optical diagnosis of Helicobacter pylori infection
Adib, Z. A., Sharifi, A. R., Kiani, M. A., Yousefi, H., Horák, D., Kostiv, U., Nabavi-Rad, A., Yadegar, A., Yaghoubi-Avini, M., & Golmohammadi, H. (2023) · Materials Advances · doi:10.1039/d3ma00612c · Cited by 9
Bionanotechnology and bioMEMS (BNM): state-of-the-art applications, opportunities, and challenges
Borenstein, J. T., Cummins, G., Dutta, A., Hamad, E. M., Hughes, M. P., Jiang, X., Lee, H., Lei, K. F., Tang, X. S., Zheng, Y., et al. (2023) · Lab on a Chip · doi:10.1039/d3lc00296a · Cited by 10
Monitoring Technologies for Quantifying Medication Adherence
Aldeer, M. M. N., Javanmard, M., Ortiz, J., & Martin, R. P. (2022) · Health informatics · doi:10.1007/978-3-030-94212-0_3 · Cited by 11
Dynamics and metabolic effects of intestinal gases in healthy humans
Tozzi, A., & Minella, R. (2024) · Biochimie · doi:10.1016/j.biochi.2024.02.001 · Cited by 8
Advances in Digital Health for Gastrointestinal Nutrition
Kim, S. W., Zhang, Y., Mauldin, K., & Limketkai, B. N. (2024) · Current Treatment Options in Gastroenterology · doi:10.1007/s11938-024-00458-0 · Cited by 8
“These features, coupled with the aforementioned home tests, could potentially advance the sophistication of personalized diets [48–51].”
Encapsulation of Gas Sensors to Operate in the Gastrointestinal Tract for Continuous Monitoring
Huang, H., de Gruijl, D., Fritz, P., Kemkar, A., Ballinger, I., Selsing, G., Chai, P. R., & Traverso, G. (2022) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors52175.2022.9967279 · Cited by 8
“A variety of research efforts have been dedicated to developing membranes that are selective permeable [3], [10].”
BackgroundUnravelling the controversy with small intestinal bacterial overgrowth
Shah, A., Ghoshal, U. C., & Holtmann, G. (2023) · Current Opinion in Gastroenterology · doi:10.1097/mog.0000000000000928 · Cited by 8
“Preliminary studies [37] provide encouraging data with good correlations of breath hydrogen and regional hydrogen patterns generated utilizing the gas-sensing capsule.”
BackgroundEdible batteries for biomedical innovation: advances, challenges, and future perspectives
Pu, Y., Wei, W., Li, S., Long, J., Gu, Y., Hong, G., & Guo, J. (2025) · Chemical Communications · doi:10.1039/d5cc01385b · Cited by 8
Fabrication of porous PDMS sponges using spontaneously self-removing sacrificial templates
Keller, A., Zainulabdeen, K., Warren, H., & Panhuis, M. I. H. (2022) · MRS Advances · doi:10.1557/s43580-021-00196-w · Cited by 8
Biotechnology applications in precision food
Siddique, A., Tayyaba, T., Imran, M., & Rahman, A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90042-3.00013-x · Cited by 10
Functionalized nanofibers for gas and volatile organic compound sensing
Bhaliya, J. D., Shah, V., & Patel, G. M. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-99461-3.00030-3 · Cited by 8
Evidence-Based and Emerging Diet Recommendations for Small Bowel Disorders
Rej, A., Potter, M. D. E., Talley, N. J., Shah, A., Holtmann, G., & Sanders, D. S. (2022) · The American Journal of Gastroenterology · doi:10.14309/ajg.0000000000001764 · Cited by 8
“shown gas-sensing capsules were able to define regional fermentation patterns using hydrogen gas profiles (82).”
MethodDickson, I. (2018) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2018.3 · Cited by 7
Gibson, P. R., & Burgell, R. (2018) · Science · doi:10.1126/science.aat8658 · Cited by 7
Self-citationMustafa, F., Noor, R., Murtaza, A., Kanwal, W., Kanwal, F., Kaleem, T., Munir, F., Umar, R. A. B., Taib, W. R. W., Krishnasamy, S., et al. (2025) · Current Pharmaceutical Design · doi:10.2174/0113816128373584250407134451 · Cited by 6
Ingestible biosensors for monitoring digestive health and nutritional monitoring
Shukla, M., & Pandya, A. (2025) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2025.06.007 · Cited by 6
Du, B., Zhang, M., Ye, J., Wang, D., Han, J., & Zhang, T. (2023) · Sensors · doi:10.3390/s23062886 · Cited by 6
Ran, P., Li, M., Zhang, K., Sun, D., Lai, Y., Liu, W., Zhong, Y., & Li, Z. (2023) · Biosensors · doi:10.3390/bios13080791 · Cited by 6
“The robust inter-observer agreement observed with these gassensing capsules and their adeptness at landmark identification indicate potential pathways to enhance the diagnostic accuracy of our envisioned intra-balloon sensor [26,27].”
BackgroundConceptual Exchanges for Understanding Free-Living and Host-Associated Microbiomes
Pfister, C. A., Light, S. H., Bohannan, B. J. M., Schmidt, T. M., Martiny, A. C., Hynson, N. A., Devkota, S., David, L. A., & Whiteson, K. (2022) · mSystems · doi:10.1128/msystems.01374-21 · Cited by 8
“Proctor's (51) call for increased quantification of the environment in the human gut may be increasingly likely with the use of ingestible sensors for oxygen, hydrogen, and carbon dioxide (81).”
BackgroundYoshida, S., Miyaguchi, H., & Nakamura, T. (2019) · Electronics · doi:10.3390/electronics8070804 · Cited by 6
Soft micro-sensotransmitters emerging
Kalantar‐Zadeh, K. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0198-8 · Cited by 6
Self-citationFuture is ready for swallowable sensors
Kalantar‐Zadeh, K., & Ward, S. A. (2019) · HepatoBiliary Surgery and Nutrition · doi:10.21037/hbsn.2018.12.13 · Cited by 6
“They can be used for monitoring carbohydrate malabsorptions and also gut motility disorders (1,3,4,6,11).”
BackgroundSelf-citationAn ingestible capsule for luminance-based diagnosis of mesenteric ischemia
Chen, J., Alexiev, A., Sergnese, A., Fabian, N. J., Pettinari, A., Cai, Y., Perepelook, V., Schmidt, K., Hayward, A. M., Guevara, A., et al. (2025) · Science Robotics · doi:10.1126/scirobotics.adx1367 · Cited by 8
Wu, Y., Liu, F., Shi, Z., Li, Y., Zhang, F., An, Z., & Liu, Q. (2026) · Device · doi:10.1016/j.device.2025.101018 · Cited by 6
Transforming healthcare through in-body bioelectronic systems
Ceto, S., Elshove, S. A., Wu, M., Ramadi, K. B., Tondera, C., Minev, I. R., Srinivasan, S. S., Lee, K., Gora, M. J., Rogers, J. A., et al. (2026) · Nature Communications · doi:10.1038/s41467-026-71188-3 · Cited by 5
Abu-Halimah, J., Majmudar, A., & Tian, B. (2023) · CCS Chemistry · doi:10.31635/ccschem.023.202303094 · Cited by 7
Design and fabrication of a parasite-inspired, millimeter-scale tissue anchoring mechanism
Maquignaz, G., Zoll, R. S., Karpelson, M., Weaver, J. C., & Wood, R. J. (2024) · PNAS Nexus · doi:10.1093/pnasnexus/pgae495 · Cited by 5
“Diagnosis meth-ods for ICRs already include imaging with optical (72, 73) or ultrasound sensors (74, 75), monitoring pH (76, 77), pressure (78, 79), and temperature (1), as well as detecting chemical (80) and biological (81) changes.”
Smart, Portable, and Noninvasive Diagnostic Biosensors for Healthcare
Kanaparthi, S., Supraja, P., & Singh, S. G. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-815743-5.00007-x · Cited by 6
Measurements for a healthy gut
Terry, B. S. (2017) · Nature Electronics · doi:10.1038/s41928-017-0012-x · Cited by 5
Tontini, G. E., Rimondi, A., Pessarelli, T., Ciprandi, G., Kurihara, H., Sorge, A., & Vecchi, M. L. (2024) · Surgical Endoscopy · doi:10.1007/s00464-024-11370-0 · Cited by 4
Ingestible electronic capsules for in situ sensing of diverse biomarkers
Zhang, C., Song, H., Zeng, J., Chen, J., Ni, C., Chung, H. U., Xu, K., Ying, B., & Nan, K. (2025) · Device · doi:10.1016/j.device.2025.100935 · Cited by 4
Self-citationLi, M., Ran, P., Zhong, Y., Jiao, Z., Liu, W., Lai, Y., Liu, L., & Wang, W. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3452234 · Cited by 4
“Furthermore, advancements in precise balloon sensor systems provide reliable references for detecting coupled physical characteristics in the upper gastrointestinal tract [18].”
BackgroundThe road ahead for applications of mechanics in drug delivery
Sarmadi, M., Krishnan, S. R., Ramadi, K. B., & Langer, R. (2022) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2022.103956 · Cited by 5
Pillai, N. V., Berean, K. J., Brkljača, R., Greve, L. J., Kasapis, S., & Kalantar‐Zadeh, K. (2018) · Journal of Functional Foods · doi:10.1016/j.jff.2018.05.054 · Cited by 4
Self-citationPour, M. N., Nikfarjam, A., Taheri, A., & Sadredini, A. R. (2019) · Micro & Nano Letters · doi:10.1049/mnl.2019.0049 · Cited by 4
Moore, M. D., Suther, C., & Zhou, Y. (2020) · Infectious Microbes & Diseases · doi:10.1097/im9.0000000000000043 · Cited by 4
“furthering understanding of the effects andmechanisms of enteric viral replication on the gut microbiome in humans.(23)”
BackgroundFukada, K., & Hayashi, K. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c08493 · Cited by 5
Zhang, X., guo, F., Zhang, W., Li, X., Zhang, X., Jin, H., Jian, J., & Jin, Q. (2020) · Optik · doi:10.1016/j.ijleo.2020.164298 · Cited by 4
Edible ResonatorsPreprint
Saravanavel, G., John, S., Gunashekar, K. R., Wyatt-Moon, G. S., Flewitt, A. J., & Sambandan, S. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2202.13782 · Cited by 5
Exploring Novel Healthcare Monitoring Modalities: Wearable, Ingestible, and Implantable Biosensors
Scheidt, D. T., Moreli, M. L., Materón, E. M., Michilini, L. M., Carrilho, E., & Brazaca, L. C. (2025) · Springer eBooks · doi:10.1007/978-981-95-2117-3_5 · Cited by 4
Yin, H., Li, Y., Wu, G., & Guo, Y. (2026) · Responsive materials · doi:10.1002/rpm2.70055 · Cited by 4
Hu, W., & Lv, X. (2025) · International Journal of Electrochemical Science · doi:10.1016/j.ijoes.2025.101178 · Cited by 3
Building A Better Bumphone: Designing Around Prison Phone Use
Verbaan, S., & Bowers, J. (2018) · CHI Conference Extended Abstracts on Human Factors in Computing Systems (CHI EA) · doi:10.1145/3170427.3188402 · Cited by 4
“With additions such as an accelerometer, a heart rate monitor and sensors that can monitor gas levels created by microbes in the human gut [23], a bumphone could be used as a health and fitness tracker which we name the Fitbutt.”
MethodNanogami: the microbiome expanded. speak your truth. listen to your gut.
Neidlinger, K., Willson, C., Truong, K. P., Hermens, H. J., & Evers, V. (2018) · ACM International Symposium on Wearable Computers (ISWC) · doi:10.1145/3267242.3267296 · Cited by 3
Amperometric Monitoring of Dissolution of pH-Responsive EUDRAGIT® Polymer Film Coatings
Mestres, J., Leonardi, F., & Mathwig, K. (2022) · Micromachines · doi:10.3390/mi13030362 · Cited by 3
“Real-time monitoring of analyte concentration profiles in the GI tract will provide valuable information about food fermentation and the effects of different diets as well as medical and nutritional supplements [6].”
BackgroundBiocompatible Sensors Are Revolutionizing Healthcare Technologies
Yang, Q., Jin, W., Lu, T., Liu, S., Yin, J., Zhou, T., & Ren, T. (2022) · Springer eBooks · doi:10.1007/978-981-16-9897-2_10 · Cited by 3
Fukada, K., Tajima, T., & Hayashi, K. (2023) · ACS Applied Electronic Materials · doi:10.1021/acsaelm.3c00539 · Cited by 3
MINIATURIZED CAPSULE SYSTEM FOR HYDROGEN SULFIDE DETECTION IN THE GASTROINTESTINAL TRACT
Stine, J. M., Botasini, S., Beardslee, L. A., Levy, J. A., & Reza Ghodssi, A. (2022) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2022.18 · Cited by 3
Ho, D., Cheng, C., Ouyang, C.-H., Lin, W., & Liao, C. (2024) · World Journal of Emergency Surgery · doi:10.1186/s13017-024-00553-8 · Cited by 3
“They have been effectively applied in measuring other vital parameters such as core temperature [9], intraabdominal pressure [10], bowel motility [11], intraluminal gas content [12], and microbiome behavior [13].”
BackgroundInternet of Things for Sustainable Human Health
Salam, A. (2024) · Internet of things · doi:10.1007/978-3-031-62162-8_7 · Cited by 3
Insights into The Human Gut Microbiome - A Review
Subramanian, B., Sundarakrishnan, B., Seshadri, K., & Valeriote, F. A. (2018) · SBV Journal of Basic Clinical and Applied Health Science · doi:10.5005/jp-journals-10082-01133 · Cited by 3
Chu, S., Uplekar, N., Liu, S., & Ghodssi, R. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.2999255 · Cited by 3
An ingestible device for automated sampling and location tracing in gastrointestinal tract
Li, T., Felton, J. A., Lewis, J., Cheng, Q., Meredith, R., Lu, H.-T., Benken, A. C., Dutta, P. P., Liao, J., Zhao, X., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0327667 · Cited by 2
“Ingest-ible devices for imaging and sensing along the GI tract have a long history with both commercial options (e.g., PillCam ® and SmartPill ® ) and exploratory research [13–16].”
Bron, A., Beltramo, C., Durif, C., Arora, T., Deschamps, C., Couturier, I., Domingo-Almenara, X., Otero, Y. F., Denis, S., de Wiele, T. V., et al. (2025) · Gut Microbes · doi:10.1080/19490976.2025.2579353 · Cited by 2
Matsuda, R., Tomita, K., Miura, S., Satoh, M., Kan, T., & Onoe, H. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202501603 · Cited by 2
“Additionally, sensors to detect specific biomarkers, such as intestinal gas [3, 4] or internal bleeding [5] have been proposed.”
Suitability of Common Ingestible Antennas for Multiplexed Gastrointestinal Biosensing
Cil, E., Soares, Í. V., Sauleau, R., & Nikolayev, D. (2025) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2025.3639918 · Cited by 2
“Di ff erent application fields of such devices include metabolite monitoring [10], hypertension monitoring [11], blood flow sensing [12], [13], blood glucose monitoring [14], [15], [16], wireless endoscopy [17], [18], [19], and gastrointestinal (GI) pH, temperature [20], and gas sensing [21].”
Chen, X., Huang, L., Ren, L., & Wang, M. (2025) · Advanced Robotics Research · doi:10.1002/adrr.202500056 · Cited by 2
Tracking in-silico Lagrangian sensors in a lab-scale stirred tank reactor
Rathi, V., Sehar, F., Sommer, F., Götschel, S., Steuwe, E., von Kameke, A., & Ruprecht, D. (2026) · Computers & Chemical Engineering · doi:10.1016/j.compchemeng.2026.109911 · Cited by 2
Daramola, O., & Nyasulu, P. S. (2020) · Lecture notes in computer science · doi:10.1007/978-3-030-45002-1_35 · Cited by 2
Small Intestinal Bacterial Overgrowth Syndrome
Okuniewicz, R., Moos, Ł., & Brzoza, Z. (2021) · Postępy Mikrobiologii - Advancements of Microbiology · doi:10.21307/pm-2021.60.3.16 · Cited by 2
Bacteria-Loaded Gastro-Retention Oral Delivery System for Alcohol Abuse
Cheng, Q., Xie, M., Li, G., Xue, W., Zeng, L., & Ma, D. (2023) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c00009 · Cited by 2
Chen, L., Low, H. R., Jiang, Y. L., Zhang, W. Y., Ao, C. K., Tan, Y. J. N., Lim, K. H., & Soh, S. (2024) · Materials Horizons · doi:10.1039/d3mh01480k · Cited by 2
Sobczyk, M., Porzak, M., Żuraw, D., Sodolska, A., Oleksa, P., & Jasiński, K. (2024) · Prospects in Pharmaceutical Sciences · doi:10.56782/pps.196 · Cited by 2
“Currently under investigation there are tests involving oral capsules that can measure in vivo hydrogen and carbon dioxide after ingestion of a carbohydrate meal [22].”
BackgroundSmall intestinal bacterial and fungal overgrowth
Bhagatwala, J., & Rao, S. S. C. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813037-7.00024-8 · Cited by 2
Aishwarya, C. V. S., Raj, J. J. J., Mandal, S. K., Reddy, C. N., & Mishra, B. (2022) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-031-04524-0_3 · Cited by 2
Design of Low Power Ni-chrome-Platinum Micro-Heater for MEMS-Based Gas Sensor in UAV Applications
Kumar, V. V., & Sasikala, G. (2023) · International Journal of Electrical and Electronics Engineering · doi:10.14445/23488379/ijeee-v10i1p112 · Cited by 2
Time to switch on to digital ethics
(2019) · Nature Electronics · doi:10.1038/s41928-019-0299-x · Cited by 2
Hurr, T. J. (2024) · Qeios · doi:10.32388/3z6x7o · Cited by 2
“The existence of oxygen, other than in the stomach, was found by using a swallowed electronic capsule capable of sensing different gases, finding oxygen in the jejunum, ilium, and, with a high-fibre diet, the colon, with excess hydrogen mitigated by oxidation [23] .”
BackgroundFlexible and Wearable Volatile Organic Compounds (VOCs) Sensing: Development and Future Perspectives
Ren, H. (2024) · European journal of applied sciences · doi:10.14738/aivp.121.16358 · Cited by 1
Intestinal Energy Absorption Is Associated with Glycemic Variability in Young, Healthy Adults
Dawson, M. A., Cheung, S. N., Frano, M. R. L., Nagpal, R., & Berryman, C. E. (2025) · Journal of Nutrition · doi:10.1016/j.tjnut.2025.05.018 · Cited by 1
Ingestible biosensors for drug delivery monitoring
Ansari, N., Dasgupta, J., & Jain, D. (2025) · Progress in molecular biology and translational science · doi:10.1016/bs.pmbts.2025.06.009 · Cited by 1
Giannoukos, S., Burton-Pimentel, K. J., Guillod, R., Vergères, G., & Pohl, D. (2025) · BMJ Open · doi:10.1136/bmjopen-2025-107256 · Cited by 1
Using breath tests in gastroenterology: Clear and reliable practitioner guide in 2025
Abufarhaneh, E. H., Ibnawadh, S., & Wong, R. K. M. (2026) · Saudi Journal of Gastroenterology · doi:10.4103/sjg.sjg_453_25 · Cited by 1
Metadata
- Authors
- Kalantar-Zadeh, K., Berean, K. J., Ha, N., Chrimes, A. F., Xu, K., Grando, D., Ou, J. Z., Pillai, N., Campbell, J. L., Brkljača, R., Taylor, K. M., Burgell, R. E., Yao, C. K., Ward, S. A., McSweeney, C. S., Muir, J. G., & Gibson, P. R.
- Affiliations
- RMIT University (AU)
- The Alfred Hospital (AU)
- Monash University (AU)
- Corresponding author
- Gibson, Peter R.
- ORCID
- Venue
- Nature Electronics
- Published
- 2018-01-08
- Volume
- 1
- Issue
- 1
- Pages
- 79-87
- ISSN
- 2520-1131 (ISSN-L)
- OpenAlex
- W2779327387
- Cited by
- 342
- References
- 52
- Citations by year
- 2026: 18 · 2025: 39 · 2024: 40 · 2023: 41 · 2022: 52 · 2021: 42 · 2020: 35 · 2019: 39 · 2018: 34
- FWCI
- 20.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springernature.com/gp/researchers/text-and-data-mining (tdm)
- www.springernature.com/gp/researchers/text-and-data-mining (vor)
- Locations
- Nature Electronics (publishedVersion)
- RMIT Research Repository (RMIT University Library) (submittedVersion)
- Funders
- National Health and Medical Research Council
- National Medical Research Council
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- oxygen sensing, hydrogen detection, carbon dioxide detection, thermal conductivity sensor, dietary fiber intake, gut fermentation, intestinal transit time, small intestine, colon, capsule localization, ultrasonography, dietary monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.