Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 215

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Soft and stretchable liquid metal transmission lines as distributed probes of multimodal deformations

Open access
Leber, Andreas, Dong, Chaoqun, Chandran, Rajasundar, Das Gupta, Tapajyoti, Bartolomei, Nicola, Sorin, Fabien·2020·Nature Electronics

Abstract

Mechanical sensing is a key functionality in soft electronics intended for applications in health monitoring, human–machine interactions and soft robotics. Current methods typically use intricate networks of sensors specific to one type of deformation and one point in space, which limits their sensing capabilities. An alternative approach to distributed sensing is electrical reflectometry, but it is challenging to build the necessary transmission lines out of soft materials. Here, we report the scalable fabrication of microstructured elastomeric fibres that integrate tens of liquid metal conductors and have the length and cross-sectional integrity necessary to successfully apply time-domain reflectometry. Our soft transmission lines allow the detection of the mode, magnitude and position of multiple simultaneous pressing and stretching events. Furthermore, as a result of the dynamically responsive conductors, the pressure sensitivity is improved by a factor of 200 compared to rigid line probes. By integrating a single soft transmission line with a single interface port into a larger fabric, our technique can be used to create an electronic textile that can decipher convoluted mechanical stimulation. A microstructured liquid metal fibre can be used as a soft transmission line probe for reflectometry, allowing electronic textiles to be created that can decipher convoluted mechanical stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41928-020-0415-y

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 215

Metadata

Authors
Leber, A., Dong, C., Chandran, R., Das Gupta, T., Bartolomei, N., & Sorin, F.
Venue
Nature Electronics
Published
2020-06-01
Volume
3
Issue
6
Pages
316-326
ISSN
2520-1131 (ISSN-L)
OpenAlex
W3032202362
Cited by
215
References
4
FWCI
8.48
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Soft and stretchable liquid metal transmission lines as distributed probes of multimodal deformations. https://app.cochat.ai/papers/10.1038/s41928-020-0415-y
The paper
Leber, A., Dong, C., Chandran, R., Das Gupta, T., Bartolomei, N., & Sorin, F. (2020). Soft and stretchable liquid metal transmission lines as distributed probes of multimodal deformations. Nature Electronics. https://doi.org/10.1038/s41928-020-0415-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.