CoChat

A biosensor for measuring NAD+ levels at the point of care

Open access
Yu, Qiuliyang, Pourmandi, Narges, Xue, Lin, Gondrand, Corentin, Fabritz, Sebastian, Bardy, Daniel, Patiny, Luc, Katsyuba, Elena, Auwerx, Johan, Johnsson, Kai · 2019 · Nature Metabolism
Cited by 55

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

The cellular level of nicotinamide adenine dinucleotide (NAD+), through its different functions, affects cellular metabolism and signalling1–3. A decrease in the NAD+ content has been associated with various pathologies and physiological aging4,5, while strategies to boost cellular NAD+ levels have been shown to be effective against age-related diseases in many animal models6. The link between decreased NAD+ levels and numerous pathologies and physiological aging has triggered the need for a simple quantification method for NAD+, ideally applicable at the point of care. Here, we introduce a bioluminescent biosensor for the rapid quantification of NAD+ levels in biological samples, which can be used either in laboratories or at the point of care. The biosensor is a semisynthetic, light-emitting sensor protein that changes the colour of emitted light from blue to red on binding of NAD+. This NAD+-dependent colour change enables the use of the biosensor in paper-based assays in which NAD+ is quantified by measuring the colour of the emitted light by using either a simple digital camera or a plate reader. We used the approach to quantify NAD+ levels in cell culture, tissue and blood samples, yielding results that agreed with those from standard testing methods. The same biosensor furthermore allows the quantification of NAD+-dependent enzymatic activities in blood samples, thus expanding its utility as a tool for point-of-care diagnostics. Yu et al. report a bioluminescence- and paper-based assay for the rapid quantification of NAD+ levels in biological samples, such as blood and tissues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s42255-019-0151-7

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 55

Metadata

Authors
Yu, Q., Pourmandi, N., Xue, L., Gondrand, C., Fabritz, S., Bardy, D., Patiny, L., Katsyuba, E., Auwerx, J., & Johnsson, K.
Venue
Nature Metabolism
Published
2019-12-13
Volume
1
Issue
12
Pages
1219-1225
ISSN
2522-5812 (ISSN-L)
OpenAlex
W2995168641
Cited by
55
References
7
FWCI
1.72
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A biosensor for measuring NAD+ levels at the point of care. https://app.cochat.ai/papers/10.1038/s42255-019-0151-7
The paper
Yu, Q., Pourmandi, N., Xue, L., Gondrand, C., Fabritz, S., Bardy, D., Patiny, L., Katsyuba, E., Auwerx, J., & Johnsson, K. (2019). A biosensor for measuring NAD+ levels at the point of care. Nature Metabolism. https://doi.org/10.1038/s42255-019-0151-7

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.