Imaging flow cytometry
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Imaging flow cytometry combines the high-event-rate nature of flow cytometry with the advantages of single-cell image acquisition associated with microscopy. The measurement of large numbers of features from the resulting images provides rich data sets that have resulted in a wide range of novel biomedical applications. In this Primer, we discuss the typical imaging flow instrumentation, the form of data acquired and the typical analysis tools that can be applied to these data. Focusing on the first commercially available imaging flow cytometer, the ImageStream (Luminex), we use examples from the literature to discuss the progression of the analysis methods used in imaging flow cytometry. These methods start from the use of simple single-image features and multiple channel gating strategies, followed by the design and use of custom features for phenotype classification, through to powerful machine and deep-learning methods. For each of these methods, we outline the processes involved in analysing typical data sets and provide details of example applications. Finally, we discuss the current limitations of imaging flow cytometry and the innovations and new instruments that are addressing these challenges. Imaging flow cytometry combines the high-event-rate nature of flow cytometry with single-cell image acquisition associated with microscopy. In this Primer, Rees et al. discuss the typical imaging flow instrumentation, the type of data acquired and how to analyse them.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Deep Residual Learning for Image Recognition
He, K., Zhang, X., Ren, S., & Sun, J. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2016.90 · Cited by 235,474
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Data-analysis strategies for image-based cell profiling
Caicedo, J. C., Cooper, S., Heigwer, F., Warchal, S., Qiu, P., Molnar, C., Vasilevich, A. S., Barry, J. D., Bansal, H. S., Kraus, O., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4397 · Cited by 739
Self-citationSensitivity measurement and compensation in spectral imaging
Ortyn, W. E., Hall, B. E., George, T. C., Frost, K., Basiji, D. A., Perry, D. J., Zimmerman, C. A., Coder, D., & Morrissey, P. J. (2006) · Cytometry Part A · doi:10.1002/cyto.a.20306 · Cited by 115
Cited by
Toxicity of Magnetic Nanoparticles in Medicine: Contributing Factors and Modern Assessment Methods
Nowak-Jary, J., & Machnicka, B. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26178586 · Cited by 25
Howell, J., Omwenga, S., Jimenez, M., & Hammarton, T. C. (2024) · PLOS ONE · doi:10.1371/journal.pone.0311367 · Cited by 10
Metadata
- Authors
- Rees, P., Summers, H. D., Filby, A., Carpenter, A. E., & Doan, M.
- Venue
- Nature Reviews Methods Primers
- Published
- 2022-11-03
- Volume
- 2
- Issue
- 1
- ISSN
- 2662-8449 (ISSN-L)
- OpenAlex
- W4308486212
- Cited by
- 176
- References
- 4
- FWCI
- 4.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging flow cytometry. https://app.cochat.ai/papers/10.1038/s43586-022-00167-x
- The paper
- Rees, P., Summers, H. D., Filby, A., Carpenter, A. E., & Doan, M. (2022). Imaging flow cytometry. Nature Reviews Methods Primers. https://doi.org/10.1038/s43586-022-00167-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.