Student or educator? Sign up with your school email and get 6 months of Pro free.

The DOI matches its Crossref record; 13 of the 14 references it cites were found in a registry or an index; 10 of the 20 sources its claims cite were checked for support.

Mitigating bias in machine learning for medicine

Open access

Abstract

Several sources of bias can affect the performance of machine learning systems used in medicine and potentially impact clinical care. Here, we discuss solutions to mitigate bias across the different development steps of machine learning-based systems for medical applications. Vokinger et al. discuss potential sources of bias in machine learning systems used in medicine. The authors propose solutions to mitigate bias across the different stages of model development, from data collection and preparation to model evaluation and application.

Overview

CoChat Summary

TL;DR

This commentary argues that bias in machine-learning systems for medicine can be introduced at each development stage—data collection and preparation, model development, model evaluation, and post-authorization deployment—and proposes mitigation strategies for each. It calls for these strategies to become best practice to prevent health-care inequality and ensure safe function for all patients.

Key findings

No original data are reported; the paper synthesizes proposed solutions across four development steps.

  • Sampling bias in training data can be replicated clinically: a system trained on melanoma images from people with white skin "might misinterpret images from patients with a darker skin tone, and might fail to diagnose melanoma," which matters because melanoma causes most skin-cancer deaths and early diagnosis is critical for cure.
  • The paper cites prior evidence of racial bias in a commercial prediction algorithm: Black patients assigned the same risk level were sicker than white patients, because the algorithm used health costs as a proxy for health needs and less money is spent on Black patients with equal need.
  • Proposed mitigations include transparency about training-data demographics and baseline characteristics, compiling datasets "as diverse and large as possible," monitoring error rates across cohorts, reporting checklists such as PROBAST, mathematical de-biasing (adversarial de-biasing, oversampling), continual learning, interpretability/explainability tools (SHAP, LIME), and post-authorization monitoring for domain shift and feedback loops.
  • The author recommends that for high-risk ML-based systems in medicine, models "might be better" limited to those that are interpretable, given that explainability can be inaccurate or non-meaningful.

Methods

This is a narrative commentary/perspective, not an empirical study; no dataset, sample, or statistical analysis is reported. The argument is organized around a four-step framework of ML system development (data collection and preparation, model development, model evaluation, deployment/post-authorization), with proposed solutions presented per step and summarized in Fig. 1. Evidence is drawn from cited prior literature and FDA policy documents (e.g., the January 2021 FDA Action Plan).

Limitations

The paper states no formal limitations section. Limitations evident in the text: the author notes that de-biasing techniques "have only recently emerged in computer science and more research is still needed to demonstrate proof-of-principle and show that de-biasing reliably achieves its intended purpose," and that ML explainability "can be inaccurate or non-meaningful due to the underlying mathematical assumptions." The recommendations are prescriptive proposals rather than validated interventions, and no quantitative evaluation of their effectiveness is provided.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s43856-021-00028-w

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Fig. 1 Strategies for mitigating bias across the different steps in machine learning systems development. Diagram outlining proposed solutions on how to mitigate bias across the different development steps of ML-based systems for medical applications: (1) Data collection and data preparation, (2) Model development, (3) Model evaluation, and (4) Deployment.
Fig. 1 Strategies for mitigating bias across the different steps in machine learning systems development. Diagram outlining proposed solutions on how to mitigate bias across the different development steps of ML-based systems for medical applications: (1) Data collection and data preparation, (2) Model development, (3) Model evaluation, and (4) Deployment.CC BY · PubMed Central

Verification

Claims the paper makes

8 Valid · 0 Not valid · 5 Not checked · 14 Own results and interpretations

13 more claims · 3 with their cited sources checked

Create a free account to see all 27 claims and to verify the 10 references still open.

See all claims — free account
  • It may state two separate claims as one. 6
  • Probably not a substantial claim. 4

Create a free account to see these claims.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

5 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 14 references

Cited by

See all 269

Metadata

Authors
Vokinger, K. N., Feuerriegel, S., & Kesselheim, A. S.
Affiliations
  • Brigham and Women's Hospital (US)
  • ETH Zurich (CH)
Corresponding author
Vokinger, Kerstin N.
Venue
Communications Medicine
Published
2021-08-23
Volume
1
Issue
1
Pages
25-25
ISSN
2730-664X (ISSN-L)
OpenAlex
W3194979994
Cited by
269
References
14
Citations by year
2026: 43 · 2025: 54 · 2024: 71 · 2023: 65 · 2022: 32 · 2021: 4
FWCI
53.77
Type
journal article
Language
en
Open access
Licence
Locations
  • Communications Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Repository for Publications and Research Data (ETH Zurich) (publishedVersion, cc-by)
  • Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, cc-by)
  • Repository for Publications and Research Data (ETH Zurich) (submittedVersion, cc-by)
  • Zurich Open Repository and Archive (University of Zurich) (submittedVersion, cc-by)
  • ETH Zürich Research Collection (cc-by)
  • Zurich Open Repository and Archive (University of Zurich)
Funders
Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Topics
  • Physical Sciences › Computer Science › Artificial Intelligence › Ethics and Social Impacts of AI
  • Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
  • Physical Sciences › Computer Science › Artificial Intelligence › Machine Learning in Healthcare
Keywords
algorithmic bias, bias mitigation, machine learning in medicine, clinical decision support, model evaluation, fairness in healthcare

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-04, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-04 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (qwen3.8-omni-flash and gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mitigating bias in machine learning for medicine. https://app.cochat.ai/papers/10.1038/s43856-021-00028-w
The paper
Vokinger, K. N., Feuerriegel, S., & Kesselheim, A. S. (2021). Mitigating bias in machine learning for medicine. Communications Medicine. https://doi.org/10.1038/s43856-021-00028-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.