Motion artefact management for soft bioelectronics
Open accessThe DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Soft bioelectronic devices can be interfaced with anatomically curved organs, such as the heart, brain and skin, to provide continuous analysis of physiological information. However, body movements and physiological activities may induce motion artefacts, which can adversely affect signal accuracy and stability. Importantly, motion artefact management is key to promoting the clinical translation of soft bioelectronics to ensure that soft bioelectronic devices can selectively detect target biological signals with high accuracy. In this Review, we discuss how body activities can affect the soft bioelectronic–tissue interface and result in motion artefact signals, including interface impedance instability motion artefacts, biopotential motion artefacts and mechanical motion artefacts. We then investigate different motion artefact management strategies, including materials engineering, device and circuit design, and algorithmic intervention, to reduce the contribution of motion artefacts to signal acquisition, processing and interpretation. Motion artefacts challenge the translational application of soft bioelectronics by distorting physiological monitoring. This Review introduces fundamental causes of motion artefacts and discusses various management strategies, including materials usage, bioelectronics design and algorithmic intervention. Soft bioelectronic systems for the monitoring of human health rely on a stable and conformal bioelectronic–tissue interface. Motion artefacts can occur due to body movements and physiological activities, and can negatively affect signal detection and interpretation in bioelectronic measurements. Motion artefact management is crucial to the clinical translation of soft bioelectronics to ensure measurement with high accuracy. Materials usage, device design, bioelectronic–tissue adhesion, sensor and circuit designs, and algorithmic intervention are effective motion artefact management strategies. Soft bioelectronic systems for the monitoring of human health rely on a stable and conformal bioelectronic–tissue interface. Motion artefacts can occur due to body movements and physiological activities, and can negatively affect signal detection and interpretation in bioelectronic measurements. Motion artefact management is crucial to the clinical translation of soft bioelectronics to ensure measurement with high accuracy. Materials usage, device design, bioelectronic–tissue adhesion, sensor and circuit designs, and algorithmic intervention are effective motion artefact management strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Self-citationFaisal, A. A., Selen, L. P. J., & Wolpert, D. M. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2258 · Cited by 2,883
Physical hydrogels composed of polyampholytes demonstrate high toughness and viscoelasticity
Sun, T. L., Kurokawa, T., Kuroda, S., Ihsan, A. B., Akasaki, T., Sato, K., Haque, M. A., Nakajima, T., & Gong, J. P. (2013) · Nature Materials · doi:10.1038/nmat3713 · Cited by 2,089
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884 · cited 1×
“…soft biological surfaces, soft bioelec-tronics are designed for seamless and conformal integration with the human body 4 , particularly for the management of diseases currently limited by delayed or inefficient medical services such as infectious diseases and care for the ageing population 5–8 .”
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721 · cited 2×
“Physical interactions are unstable in dynamic tissues owing to their weak strength, and typically only provide adhesion for thin devices of less than 5 μm in thickness 134,143,144 .”
A low-power low-noise cmos for amplifier neural recording applications
Harrison, R. R., & Charles, C. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.811979 · Cited by 1,695
The stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515 · cited 1×
“85,86).”
Xu, S., Zhang, Y., Cho, J., Lee, J., Huang, X., Jia, L., Fan, J. A., Su, Y., Su, J., Zhang, H., et al. (2013) · Nature Communications · doi:10.1038/ncomms2553 · Cited by 1,404
Wearable and flexible electronics for continuous molecular monitoring
Yang, Y., & Gao, W. (2019) · Chemical Society Reviews · doi:10.1039/c7cs00730b · Cited by 1,315
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306 · cited 1×
“…employ mechanical sensors to capture biophysical parameters, such as stress, pressure and deformation, enabling the detection of biomechanical processes within the body, including wrist pulse, respiration movements and body-bending signals, through biomechanical-to-electrical conversion 32 .”
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082 · cited 1×
“For example, the nervous system, including the brain and spinal cord 59,60 , is characterized by low stretch-ability.”
Skin-integrated wireless haptic interfaces for virtual and augmented reality
Yu, X., Xie, Z., Yu, Y., Lee, J., Vazquez-Guardado, A., Luan, H., Ruban, J., Ning, X., Akhtar, A., Li, D., et al. (2019) · Nature · doi:10.1038/s41586-019-1687-0 · Cited by 1,025
Choi, S., Han, S. I., Jung, D., Hwang, H. J., Lim, C., Bae, S., Park, O. K., Tschabrunn, C. M., Lee, M., Bae, S. Y., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0226-8 · Cited by 984 · cited 1×
“Geometric yielding of ultrathin filamentary serpentine traces under stress allows tunability and conformability to living tissues 70,77,101,102 .”
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · cited 1×
“Customizing the functionality of soft bioelectronics based on specific needs may contribute to personalized and precise health-care monitoring 226–228 .”
The chemistry behind catechol-based adhesion
Saiz‐Poseu, J., Mancebo‐Aracil, J., Nador, F., Busqué, F., & Ruiz‐Molina, D. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201801063 · Cited by 850
A transparent bending-insensitive pressure sensor
Lee, S., Reuveny, A., Reeder, J., Lee, S., Jin, H., Liu, Q., Yokota, T., Sekitani, T., Isoyama, T., Abe, Y., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.324 · Cited by 833
Han, L., Lu, X., Wang, M., Gan, D., Deng, W., Wang, K., Fang, L., Liu, K., Chan, C. W., Tang, Y., et al. (2017) · Small · doi:10.1002/smll.201601916 · Cited by 699
Xu, L., Gutbrod, S. R., Bonifas, A. P., Su, Y., Sulkin, M. S., Lu, N., Chung, H.-J., Jang, K.-I., Liu, Z., Ying, M., et al. (2014) · Nature Communications · doi:10.1038/ncomms4329 · Cited by 634 · cited 2×
“For example, elastomers, such as polydimethylsiloxane (PDMS) 69 , silicone 70,71 , polystyrene-ethylene-butylene-styrene 16 , polyurethane 72 and PDMS–isophorone bisurea 0.6 –methylenebis(phenyl urea) 0.4 (refs.”
InfluentialWearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613 · cited 5×
“For example, biochemical sensors can initiate chemical reactions with body fluids on the skin, such as electrolytes (for example, Na + , K + and Ca 2+ ) and organic molecules (for example, glucose, lactate, hormones), generating electrical signals for real-time biochemical parameter measurement 3 .”
InfluentialAn electrically conductive silver–polyacrylamide–alginate hydrogel composite for soft electronics
Ohm, Y., Pan, C., Ford, M. J., Huang, X., Liao, J., & Majidi, C. (2021) · Nature Electronics · doi:10.1038/s41928-021-00545-5 · Cited by 546
Materials for flexible bioelectronic systems as chronic neural interfaces
Song, E., Li, J., Won, S. M., Bai, W., & Rogers, J. A. (2020) · Nature Materials · doi:10.1038/s41563-020-0679-7 · Cited by 498
Stretchable distributed fiber-optic sensors
Bai, H., Li, S., Barreiros, J., Tu, Y., Pollock, C. R., & Shepherd, R. F. (2020) · Science · doi:10.1126/science.aba5504 · Cited by 490
Kim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474 · cited 1×
“Consequently, such modified bioelectronics can adhere to human skin, even in dynamic conditions and wet environments 138 .”
Learning human–environment interactions using conformal tactile textiles
Luo, Y., Li, Y., Sharma, P., Shou, W., Wu, K., Foshey, M., Li, B., Palacios, T., Torralba, A., & Matusik, W. (2021) · Nature Electronics · doi:10.1038/s41928-021-00558-0 · Cited by 395 · cited 1×
“Finally, by leveraging interlocking yarn loops crafted through knitting, a soft and stretchable fabric can be designed that exhibits high shape conformability and stretchability 110,111 .”
Ershad, F., Thukral, A., Yue, J., Comeaux, P., Lu, Y., Shim, H., Sim, K., Kim, N.-I., Rao, Z., Guevara, R., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-17619-1 · Cited by 355
Lee, K., Ni, X., Lee, J. Y., Arafa, H., Pe, D. J., Xu, S., Avila, R., Irie, M., Lee, J. H., Easterlin, R. L., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0480-6 · Cited by 349 · cited 1×
“A high-pass filter (>10 Hz) can selectively capture biomechanical signals across high-frequency ranges, including acoustic vibrations and cardiac activity, while minimizing interference from respiration and locomotion at low frequencies 197,198 .”
Morphing electronics enable neuromodulation in growing tissue
Liu, Y., Li, J., Song, S., Kang, J., Tsao, Y., Chen, S., Mottini, V., McConnell, K., Xu, W., Zheng, Y.-Q., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-020-0495-2 · Cited by 325
Stretchable transistors and functional circuits for human-integrated electronics
Dai, Y., Hu, H., Wang, M., Xu, J., & Wang, S. (2021) · Nature Electronics · doi:10.1038/s41928-020-00513-5 · Cited by 315 · cited 1×
“Unlike transistors made from rigid materials (such as metals and silicon semiconductors), soft transistors are typically constructed from intrinsically stretchable materials 190 , including polymers, carbon-based compounds or other organic molecules 11,191–193 .”
Self-citationZhang, Y., Zheng, N., Cao, Y., Wang, F., Wang, P., Ma, Y., Lu, B., Hou, G., Fang, Z., Liang, Z., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw1066 · Cited by 314
Viscoelastic surface electrode arrays to interface with viscoelastic tissues
Tringides, C. M., Vachicouras, N., de Lázaro, I., Wang, H., Trouillet, A., Seo, B. R., Elosegui-Artola, A., Fallegger, F., Shin, Y., Casiraghi, C., et al. (2021) · Nature Nanotechnology · doi:10.1038/s41565-021-00926-z · Cited by 309 · cited 1×
“67,73) can serve as substrates in soft bioelectronics (Table 1 and Fig.”
Sim, K., Rao, Z., Zou, Z., Ershad, F., Lei, J., Thukral, A., Chen, J., Huang, Q.-A., Xiao, J., & Yu, C. (2019) · Science Advances · doi:10.1126/sciadv.aav9653 · Cited by 305 · cited 1×
“Physical interactions are unstable in dynamic tissues owing to their weak strength, and typically only provide adhesion for thin devices of less than 5 μm in thickness 134,143,144 .”
Self-citationChoi, Y. S., Hsueh, Y.-Y., Koo, J., Yang, Q., Avila, R., Hu, B., Xie, Z., Lee, G., Ning, Z., Liu, C., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19660-6 · Cited by 292 · cited 1×
“For example, elastomers, such as polydimethylsiloxane (PDMS) 69 , silicone 70,71 , polystyrene-ethylene-butylene-styrene 16 , polyurethane 72 and PDMS–isophorone bisurea 0.6 –methylenebis(phenyl urea) 0.4 (refs.”
InfluentialIlluminating the dark spaces of healthcare with ambient intelligence
Haque, A., Milstein, A., & Fei-Fei, L. (2020) · Nature · doi:10.1038/s41586-020-2669-y · Cited by 274
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
An ultraflexible organic differential amplifier for recording electrocardiograms
Sugiyama, M., Uemura, T., Kondo, M., Akiyama, M., Namba, N., Yoshimoto, S., Noda, Y., Araki, T., & Sekitani, T. (2019) · Nature Electronics · doi:10.1038/s41928-019-0283-5 · Cited by 177
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Rapid prototyping of soft bioelectronic implants for use as neuromuscular interfaces
Afanasenkau, D., Kalinina, D., Lyakhovetskii, V., Tondera, C., Gorsky, O., Moosavi, S., Pavlova, N., Merkulyeva, N., Kalueff, A. V., Minev, I. R., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00615-7 · Cited by 148 · cited 1×
“For example, the nervous system, including the brain and spinal cord 59,60 , is characterized by low stretch-ability.”
A Bioinspired Stretchable Sensory‐Neuromorphic System
Kim, S. H., Baek, G. W., Yoon, J., Seo, S., Park, J., Hahm, D., Chang, J. H., Seong, D., Seo, H., Oh, S., et al. (2021) · Advanced Materials · doi:10.1002/adma.202104690 · Cited by 142
Jeong, H., Lee, J. Y., Lee, K., Kang, Y. J., Kim, J.-T., Avila, R., Tzavelis, A., Kim, J., Ryu, H., Kwak, S. S., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg3092 · Cited by 121 · cited 7×
“The acquisition channel can detect both the target signals and irrelevant biopotential signals 55,156,157 .”
InfluentialAdaptive self-healing electronic epineurium for chronic bidirectional neural interfaces
Song, K.-I., Seo, H., Seong, D., Kim, S., Yu, K. J., Kim, Y.-C., Kim, J., Kwon, S. J., Han, H.-S., Youn, I., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18025-3 · Cited by 120 · cited 1×
“To achieve tissue-level stretchability in soft bioelectronics, polymer materials are commonly used owing to their long-chain molecular structure, intermolecular slippages between chains 63 and the reversible dissipation of strain energy through dynamic bonds 64–68 .”
Xu, S., Rwei, A. Y., Vwalika, B., Chisembele, M. P., Stringer, J. S. A., Ginsburg, A. S., & Rogers, J. A. (2021) · The Lancet Digital Health · doi:10.1016/s2589-7500(21)00001-7 · Cited by 57
Cited by
Yang, H., Zhu, Z., Ni, S., Wang, X., Nie, Y., Tao, C., Zou, D., Jiang, W., Zhao, Y., Zhou, Z., et al. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116853 · Cited by 24
Design and applications of conductive polymers in wearable electrophysiological sensing
Zhou, N., Zhang, L., Cui, T., Wu, P., & Lei, Z. (2025) · Science China Technological Sciences · doi:10.1007/s11431-025-3114-6 · Cited by 9
Metadata
- Authors
- Yin, J., Wang, S., Tat, T., & Chen, J.
- Venue
- Nature Reviews Bioengineering
- Published
- 2024-04-15
- Volume
- 2
- Issue
- 7
- Pages
- 541-558
- ISSN
- 2731-6092 (ISSN-L)
- OpenAlex
- W4394805847
- Cited by
- 220
- References
- 42
- FWCI
- 14.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.