Sensitive PCR method for the detection and real-time quantification of human cells in xenotransplantation systems
Open accessThe DOI matches its Crossref record.
Abstract
The sensitive detection of human cells in immunodeficient rodents is a prerequisite for the monitoring of micrometastasis of solid tumours, dissemination of leukaemic cells, or engraftment of haematological cells. We developed a universally applicable polymerase chain reaction method for the detection of a human-specific 850-bp fragment of the alpha-satellite DNA on human chromosome 17. The method allows the detection of one human cell in 10(6) murine cells and could be established as both, a conventional DNA polymerase chain reaction-assay for routine screening, and a quantitative real-time polymerase chain reaction-assay using TaqMan-methodology. It was applied to the following xenotransplantation systems in SCID and NOD/SCID mice: (1) In a limiting dilution assay, cells of the MDA-MB 435 breast carcinoma were injected into the mammary fat pad of NOD/SCID mice. It could be shown that 10 cells mouse(-1) were sufficient to induce a positive polymerase chain reaction signal in liver and lung tissue 30 days after transplantation as an indicator for micrometastasis. At this time a palpable tumour was not yet detectable in the mammary fat pad region. (2) Cells of a newly established human acute lymphatic leukaemia were administered intraperitoneally to SCID mice. These cells apparently disseminated and were detectable as early as day 50 in the peripheral blood of living mice, while the leukaemia manifestation was delayed by day 140. (3) In a transplantation experiment using mature human lymphocytes we wanted to standardise conditions for a successful survival of these cells in NOD/SCID mice. It was established that at least 5 x 10(7) cells given intravenously were necessary and that the mice had to be conditioned by 2 Gy body irradiation to get positive polymerase chain reaction bands in several organs. (4) Engraftment studies with blood stem cells originating from cytapheresis samples of tumour patients or from cord blood were undertaken in NOD/SCID mice in order to define conditions of successful engraftment and to use this model for further optimisation strategies. The polymerase chain reaction method presented allowed a reliable prediction of positive engraftment and agreed well with the results of immunohistochemical or FACS analysis. All together, the polymerase chain reaction method developed allows a sensitive and reliable detection of low numbers of human cells in immunodeficient hosts. In combination with real-time (TaqMan) technique it allows an exact quantification of human cells. As this method can be performed with accessible material of living animals, follow up studies for the monitoring of therapeutic interventions are possible in which the survival time of mice as evaluation criteria can be omitted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
MACC1, a newly identified key regulator of HGF-MET signaling, predicts colon cancer metastasis
Stein, U., Walther, W., Arlt, F., Schwabe, H., Smith, J., Fichtner, I., Birchmeier, W., & Schlag, P. M. (2009) · Nature Medicine · doi:10.1038/nm.1889 · Cited by 480
Self-citationEngraftment Potential of Human Amnion and Chorion Cells Derived from Term Placenta
Bailo, M., Soncini, M., Vertua, E., Signoroni, P. B., Sanzone, S., Lombardi, G., Arienti, D., Calamani, F., Zatti, D., Paul, P., et al. (2004) · Transplantation · doi:10.1097/01.tp.0000144606.84234.49 · Cited by 360
Shi, M., Li, J., Liao, L., Chen, B., Li, B., Chen, L., Jia, H., & Zhao, R. C. (2007) · Haematologica · doi:10.3324/haematol.10669 · Cited by 339
Hung, S.-C., Pochampally, R. R., Hsu, S.-C., Sanchez, C., Chen, S.-C., Spees, J., & Prockop, D. J. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000416 · Cited by 317
Palm, D., Lang, K., Niggemann, B., Drell, T. L., Masur, K., Zaenker, K. S., & Entschladen, F. (2006) · International Journal of Cancer · doi:10.1002/ijc.21723 · Cited by 298
Metadata
- Authors
- Becker, M., Nitsche, A., Neumann, C., Aumann, J., Junghahn, I., & Fichtner, I.
- Venue
- British Journal of Cancer
- Published
- 2002-11
- Volume
- 87
- Issue
- 11
- Pages
- 1328-1335
- ISSN
- 0007-0920 (ISSN-L)
- 1532-1827
- OpenAlex
- W1989561818
- Cited by
- 115
- References
- 0
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitive PCR method for the detection and real-time quantification of human cells in xenotransplantation systems. https://app.cochat.ai/papers/10.1038/sj.bjc.6600573
- The paper
- Becker, M., Nitsche, A., Neumann, C., Aumann, J., Junghahn, I., & Fichtner, I. (2002). Sensitive PCR method for the detection and real-time quantification of human cells in xenotransplantation systems. British Journal of Cancer. https://doi.org/10.1038/sj.bjc.6600573
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.