Abstract

Objectives: Bioimpedance analysis (BIA) methods have potential to predict appendicular skeletal muscle mass (SM), although available 50 kHz prediction models include, in addition to impedance (Z), an independent age term. An age term in models is undesirable as it reflects incomplete understanding of underlying conduction physiology. This study tested the hypothesis, based on fluid distribution models related to aging, that appendicular SM bioimpedance analysis (BIA) prediction models would no longer include an independent age term, after first controlling for stature-adjusted appendicular impedance (height2/Z), at injected frequencies greater than 50 kHz.Design: Cross-sectional evaluation of adults who had segmental Z and phase angle (Φ) measured with multiple frequency BIA, and arm and leg SM with dual-energy X-ray absorptiometry (DXA). Skeletal muscle prediction models were developed with appendicular SM as dependent variable and height2/Z, gender, age and Φ as potential independent variables.Results: Examination of hypothesis in 49 subjects indicated: both arm and leg SM were highly correlated with height2/segmental Z at frequencies ranging from 1–300 kHz; gender was significant covariate in prediction models only at 1 kHz; age remained a significant covariate after controlling for height2/segmental Z at all frequencies; Φ did not add significantly to models; and SM prediction models gave maximum R2 at 50 kHz for arm but R2 continued to rise up to 300 kHz for leg.Conclusion: Although multifrequency BIA did not eliminate SM prediction model age term, our findings suggest injected frequencies up to 300 kHz may have advantages for evaluating leg SM over conventional 50 kHz method.Sponsorship: This study was in-part supported by NIH Grant RO1-NIDDK 42618 and a Scholarship awarded to Dr Pietrobelli from University of Milan, H San Raffaele, Italy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/sj.ejcn.1600592

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 93

Metadata

Authors
Pietrobelli, A., Morini, P., Battistini, N., Chiumello, G., Nuñez, C., & Heymsfield, S.
Venue
European Journal of Clinical Nutrition
Published
1998-07-01
Volume
52
Issue
7
Pages
507-511
ISSN
  • 0954-3007 (ISSN-L)
  • 1476-5640
OpenAlex
W2022649431
Cited by
93
References
2
FWCI
1.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Appendicular skeletal muscle mass: prediction from multiple frequency segmental bioimpedance analysis. https://app.cochat.ai/papers/10.1038/sj.ejcn.1600592
The paper
Pietrobelli, A., Morini, P., Battistini, N., Chiumello, G., Nuñez, C., & Heymsfield, S. (1998). Appendicular skeletal muscle mass: prediction from multiple frequency segmental bioimpedance analysis. European Journal of Clinical Nutrition. https://doi.org/10.1038/sj.ejcn.1600592

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.