When Perfusion Meets Diffusion: in vivo Measurement of Water Permeability in Human Brain
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Quantification of water permeability can improve the accuracy of perfusion measurements obtained with arterial spin labeling (ASL) methods, and may provide clinically relevant information regarding the functional status of the microvasculature. The amount of labeled water in the vascular and tissue compartments in an ASL experiment can be estimated based on their distinct diffusion characteristics, and in turn, water permeability determined from the relative vascular and tissue contributions. In the present study, a hybrid magnetic resonance imaging technique was introduced by marrying a continuous ASL method with a twice-refocused spin—echo diffusion sequence. Series of diffusion-weighted ASL signals were acquired with systematically varied b values. The signals were modeled with fast and slow decaying components that were associated with the vascular and tissue compartments, respectively. The relative amount of labeled water in the tissue compartment increased from 61% to 74% and to 86% when the postlabeling delay time was increased from 0.8 to 1.2 and to 1.5 secs. With a b value of 50 secs/mm 2 the capillary contribution (fast component) of the ASL signal could be effectively minimized. Using the single-pass approximation model, the water permeability of gray matter in the human brain was estimated based on the derived relative water fractions in the tissue and microvasculature. The potential for in vivo magnetic resonance mapping of water permeability was showed using two diffusion weighted ASL measurements with b = 0 and 50 secs/mm 2 in both healthy subjects and a case of brain tumor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The capillary network: A link between IVIM and classical perfusion
Bihan, D. L., & Turner, R. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910270116 · Cited by 423 · cited 1×
“Additionally, the raw EPI intensities of the control acquisitions (M) were measured within the gray matter ROIs, and fitted based on the bi-exponential model (equation (1)) as described above (Le Bihan and Turner, 1992).”
Technical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291 · cited 1×
“Arterial spin labeling (ASL) methods use magnetically labeled blood water as an endogenous contrast agent to measure perfusion (Detre and Wang, 2002).”
Self-citation
Cited by
Functional morphology of the blood–brain barrier in health and disease
Liebner, S., Dijkhuizen, R. M., Reiss, Y., Plate, K. H., Agalliu, D., & Constantin, G. (2018) · Acta Neuropathologica · doi:10.1007/s00401-018-1815-1 · Cited by 872
“MRI methods that enable quantification of transvascular water exchange based on perfusion and diffusion measurements have also been proposed [132].”
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Thrippleton, M. J., Backes, W. H., Sourbron, S., Ingrisch, M., van Osch, M. J. P., Dichgans, M., Fazekas, F., Ropele, S., Frayne, R., van Oostenbrugge, R. J., et al. (2019) · Alzheimer's & Dementia · doi:10.1016/j.jalz.2019.01.013 · Cited by 252
Sigmund, E. E., Vivier, P.-H., Sui, D., Lamparello, N. A., Tantillo, K., Mikheev, A., Rusinek, H., Babb, J. S., Storey, P., Lee, V. S., et al. (2012) · Radiology · doi:10.1148/radiol.12111327 · Cited by 226
Ohene, Y., Harrison, I. F., Nahavandi, P., Ismail, O., Bird, E. V., Ottersen, O. P., Nagelhus, E. A., Thomas, D. L., Lythgoe, M. F., & Wells, J. A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.12.026 · Cited by 171
Shao, X., Ma, S. J., Casey, M., D’Orazio, L., Ringman, J. M., & Wang, D. J. J. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27632 · Cited by 168
MRI measurements of Blood-Brain Barrier function in dementia: A review of recent studies
Raja, R., Rosenberg, G. A., & Caprihan, A. (2018) · Neuropharmacology · doi:10.1016/j.neuropharm.2017.10.034 · Cited by 167
Yin, H., Lu, Z., Deng, Y., Tian, X., & Gong, Q. (2026) · Ageing Research Reviews · doi:10.1016/j.arr.2025.102952 · Cited by 6
Metadata
- Authors
- Wang, J., Fernández-Seara, M. A., Wang, S., & Lawrence, K. S. S.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2007-04
- Volume
- 27
- Issue
- 4
- Pages
- 839-849
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W1995406162
- Cited by
- 118
- References
- 2
- FWCI
- 0.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.