Monitoring a bioprocess for ethanol production using FT-MIR and FT-Raman spectroscopy
Open accessThe DOI matches its Crossref record.
Abstract
The application of Fourier transform mid-infrared (FT-MIR) spectroscopy and Fourier transform Raman (FT-Raman) spectroscopy for process and quality control of fermentative production of ethanol was investigated. FT-MIR and FT-Raman spectroscopy along with multivariate techniques were used to determine simultaneously glucose, ethanol, and optical cell density of Saccharomyces cerevisiae during ethanol fermentation. Spectroscopic measurement of glucose and ethanol were compared and validated with the high-performance liquid chromatography (HPLC) method. Spectral wave number regions were selected for partial least-squares (PLS) regression and principal component regression (PCR) and calibration models for glucose, ethanol, and optical cell density were developed for culture samples. Correlation coefficient (R(2)) value for the prediction for glucose and ethanol was more than 0.9 using various calibration methods. The standard error of prediction for the PLS first-derivative calibration models for glucose, ethanol, and optical cell density were 1.938 g/l, 1.150 g/l, and 0.507, respectively. Prediction errors were high with FT-Raman because the Raman scattering of the cultures was weak. Results indicated that FT-MIR spectroscopy could be used for rapid detection of glucose, ethanol, and optical cell density in S. cerevisiae culture during ethanol fermentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
FERRARIS, C. J. (2007) · Zootaxa · doi:10.11646/zootaxa.1418.1.1 · Cited by 713
Esmonde-White, K. A., Cuellar, M., Uerpmann, C., Lenain, B., & Lewis, I. R. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9824-1 · Cited by 332
Abu‐Absi, N. R., Kenty, B. M., Cuellar, M. E., Borys, M. C., Sakhamuri, S., Strachan, D. J., Hausladen, M. C., & Li, Z. J. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23023 · Cited by 322
“Both near infrared (NIR) and mid-infrared (MIR) spectroscopy have been extensively applied for monitoring a variety of bioprocesses (Card et al., 2008; McGovern et al., 2002; Sivakesava et al., 2001a,b).”
BackgroundFisher, A. C., Kamga, M.-H., Agarabi, C., Brorson, K., Lee, S. L., & Yoon, S. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.08.008 · Cited by 180
Whelan, J., Craven, S., & Glennon, B. (2012) · Biotechnology Progress · doi:10.1002/btpr.1590 · Cited by 159
Optical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151
Berry, B., Moretto, J., Matthews, T., Smelko, J., & Wiltberger, K. (2015) · Biotechnology Progress · doi:10.1002/btpr.2035 · Cited by 142
Bhatia, H., Mehdizadeh, H., Drapeau, D., & Yoon, S. (2018) · Engineering in Life Sciences · doi:10.1002/elsc.201700084 · Cited by 87
On‐line monitoring of Phaffia rhodozyma fed‐batch process with in situ dispersive raman spectroscopy
Cannizzaro, C., Rhiel, M., Marison, I., & von Stockar, U. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10698 · Cited by 70
“In another study on yeast fermentation, an FT Raman instrument was used to analyze glucose and ethanol samples without any pretreatment (Sivakesava et al., 2001).”
Method
Metadata
- Authors
- Sivakesava, S., Irudayaraj, J., & Demirci, A.
- Venue
- Journal of Industrial Microbiology and Biotechnology
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-04-01
- Volume
- 26
- Issue
- 4
- Pages
- 185-190
- ISSN
- 1367-5435 (ISSN-L)
- 1476-5535
- OpenAlex
- W1983853149
- Cited by
- 104
- References
- 0
- FWCI
- 4.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.