The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A transparent broadband ultrasonic detector based on an optical micro-ring resonator for photoacoustic microscopy
Open accessAbstract
Photoacoustic microscopy (PAM) does not rely on contrast agent to image the optical absorption contrast in biological tissue. It is uniquely suited for measuring several tissue physiological parameters, such as hemoglobin oxygen saturation, that would otherwise remain challenging. Researchers are designing new clinical diagnostic tools and multimodal microscopic systems around PAM to fully unleash its potential. However, the sizeable and opaque piezoelectric ultrasonic detectors commonly used in PAM impose a serious constraint. Our solution is a coverslip-style optically transparent ultrasound detector based on a polymeric optical micro-ring resonator (MRR) with a total thickness of 250 μm. It enables highly-sensitive ultrasound detection over a wide receiving angle with a bandwidth of 140 MHz, which corresponds to a photoacoustic saturation limit of 287 cm(-1), at an estimated noise-equivalent pressure (NEP) of 6.8 Pa. We also established a theoretical framework for designing and optimizing the MRR for PAM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Cited by
A practical guide to photoacoustic tomography in the life sciences
Wang, L. V., & Yao, J. (2016) · Nature Methods · doi:10.1038/nmeth.3925 · Cited by 1,394
Sensitivity of photoacoustic microscopy
Yao, J., & Wang, L. V. (2014) · Photoacoustics · doi:10.1016/j.pacs.2014.04.002 · Cited by 418
Ultrasensitive plano-concave optical microresonators for ultrasound sensing
Guggenheim, J. A., Li, J., Allen, T. J., Colchester, R. J., Noimark, S., Ogunlade, O., Parkin, I. P., Papakonstantinou, I., Desjardins, A. E., Zhang, E. Z., et al. (2017) · Nature Photonics · doi:10.1038/s41566-017-0027-x · Cited by 391
Looking at sound: optoacoustics with all-optical ultrasound detection
Wissmeyer, G., Pleitez, M. A., Rosenthal, A., & Ntziachristos, V. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0036-7 · Cited by 374
Clinical translation of photoacoustic imaging
Park, J., Choi, S., Knieling, F., Clingman, B., Bohndiek, S., Wang, L. V., & Kim, C. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00240-y · Cited by 275
Sensitive, small, broadband and scalable optomechanical ultrasound sensor in silicon photonics
Westerveld, W. J., Mahmud-Ul-Hasan, M., Shnaiderman, R., Ntziachristos, V., Rottenberg, X., Severi, S., & Rochus, V. (2021) · Nature Photonics · doi:10.1038/s41566-021-00776-0 · Cited by 257
Metadata
- Authors
- Li, H., Dong, B., Zhang, Z., Zhang, H. F., & Sun, C.
- Venue
- Scientific Reports
- Published
- 2014-03-28
- Volume
- 4
- Issue
- 1
- Pages
- 4496-4496
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2004196471
- Cited by
- 224
- References
- 1
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.