The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Looking at sound: optoacoustics with all-optical ultrasound detection
Open accessAbstract
Originally developed for diagnostic ultrasound imaging, piezoelectric transducers are the most widespread technology employed in optoacoustic (photoacoustic) signal detection. However, the detection requirements of optoacoustic sensing and imaging differ from those of conventional ultrasonography and lead to specifications not sufficiently addressed by piezoelectric detectors. Consequently, interest has shifted to utilizing entirely optical methods for measuring optoacoustic waves. All-optical sound detectors yield a higher signal-to-noise ratio per unit area than piezoelectric detectors and feature wide detection bandwidths that may be more appropriate for optoacoustic applications, enabling several biomedical or industrial applications. Additionally, optical sensing of sound is less sensitive to electromagnetic noise, making it appropriate for a greater spectrum of environments. In this review, we categorize different methods of optical ultrasound detection and discuss key technology trends geared towards the development of all-optical optoacoustic systems. We also review application areas that are enabled by all-optical sound detectors, including interventional imaging, non-contact measurements, magnetoacoustics, and non-destructive testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Kersey, A. D., Davis, M. A., Patrick, H. J., LeBlanc, M., Koo, K. P., Askins, C. G., Putnam, M. A., & Friebele, E. J. (1997) · Journal of Lightwave Technology · doi:10.1109/50.618377 · Cited by 3,599
Photoacoustic imaging in biomedicine
Xu, M., & Wang, L. V. (2006) · Review of Scientific Instruments · doi:10.1063/1.2195024 · Cited by 2,700
Biomedical photoacoustic imaging
Beard, P. (2011) · Interface Focus · doi:10.1098/rsfs.2011.0028 · Cited by 2,205
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Self-citationYao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Advances in real-time multispectral optoacoustic imaging and its applications
Taruttis, A., & Ntziachristos, V. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.29 · Cited by 594
Self-citationAmerican National Standard for the Safe Use of Lasers.
(1975) · Annals of Internal Medicine · doi:10.7326/0003-4819-82-1-132_2 · Cited by 498
Light In and Sound Out: Emerging Translational Strategies for Photoacoustic Imaging
Zackrisson, S., van de Ven, S. M. W. Y., & Gambhir, S. S. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-2387 · Cited by 480
Qiu, Y., Gigliotti, J., Wallace, M., Griggio, F., Demore, C., Cochran, S., & Trolier-McKinstry, S. (2015) · Sensors · doi:10.3390/s150408020 · Cited by 395
Cited by
Sensitive, small, broadband and scalable optomechanical ultrasound sensor in silicon photonics
Westerveld, W. J., Mahmud-Ul-Hasan, M., Shnaiderman, R., Ntziachristos, V., Rottenberg, X., Severi, S., & Rochus, V. (2021) · Nature Photonics · doi:10.1038/s41566-021-00776-0 · Cited by 257
Self-citation
Metadata
- Authors
- Wissmeyer, G., Pleitez, M. A., Rosenthal, A., & Ntziachristos, V.
- Venue
- Light: Science & Applications
- Published
- 2018-08-15
- Volume
- 7
- Issue
- 1
- Pages
- 53-53
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W2885304391
- Cited by
- 374
- References
- 52
- FWCI
- 11.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Looking at sound: optoacoustics with all-optical ultrasound detection. https://app.cochat.ai/papers/10.1038/s41377-018-0036-7
- The paper
- Wissmeyer, G., Pleitez, M. A., Rosenthal, A., & Ntziachristos, V. (2018). Looking at sound: optoacoustics with all-optical ultrasound detection. Light: Science & Applications. https://doi.org/10.1038/s41377-018-0036-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.