Cryptochrome-dependent magnetic field effect on seizure response in Drosophila larvae
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The mechanisms that facilitate animal magnetoreception have both fascinated and confounded scientists for decades and its precise biophysical origin remains unclear. Among the proposed primary magnetic sensors is the flavoprotein, cryptochrome, which is thought to provide geomagnetic information via a quantum effect in a light-initiated radical pair reaction. Despite recent advances in the radical pair model of magnetoreception from theoretical, molecular and animal behaviour studies, very little is known of a possible signal transduction mechanism. We report a substantial effect of magnetic field exposure on seizure response in Drosophila larvae. The effect is dependent on cryptochrome, the presence and wavelength of light and is blocked by prior ingestion of typical antiepileptic drugs. These data are consistent with a magnetically-sensitive, photochemical radical pair reaction in cryptochrome that alters levels of neuronal excitation and represent a vital step forward in our understanding of the signal transduction mechanism involved in animal magnetoreception.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic orientation and magnetoreception in birds and other animals
Wiltschko, W., & Wiltschko, R. (2005) · Journal of Comparative Physiology A · doi:10.1007/s00359-005-0627-7 · Cited by 587
Cryptochrome mediates light-dependent magnetosensitivity in Drosophila
Gegear, R. J., Casselman, A., Waddell, S., & Reppert, S. M. (2008) · Nature · doi:10.1038/nature07183 · Cited by 421
Cryptochrome Mediates Light-Dependent Magnetosensitivity of Drosophila's Circadian Clock
Yoshii, T., Ahmad, M., & Helfrich-Förster, C. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000086 · Cited by 232
Structure of full-length Drosophila cryptochrome
Zoltowski, B. D., Vaidya, A. T., Top, D., Widom, J., Young, M. W., & Crane, B. R. (2011) · Nature · doi:10.1038/nature10618 · Cited by 163
Cited by
The Radical-Pair Mechanism of Magnetoreception
Hore, P. J., & Mouritsen, H. (2016) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-032116-094545 · Cited by 813
Magnetic field effects in biology from the perspective of the radical pair mechanism
Zadeh-Haghighi, H., & Simon, C. (2022) · Journal of The Royal Society Interface · doi:10.1098/rsif.2022.0325 · Cited by 197
Radical triads, not pairs, may explain effects of hypomagnetic fields on neurogenesis
Ramsay, J., & Kattnig, D. R. (2022) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1010519 · Cited by 26
Metadata
- Authors
- Marley, R., Giachello, C. N. G., Scrutton, N. S., Baines, R. A., & Jones, A. R.
- Venue
- Scientific Reports
- Published
- 2014-07-23
- Volume
- 4
- Issue
- 1
- Pages
- 5799-5799
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2129145107
- Cited by
- 75
- References
- 4
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cryptochrome-dependent magnetic field effect on seizure response in Drosophila larvae. https://app.cochat.ai/papers/10.1038/srep05799
- The paper
- Marley, R., Giachello, C. N. G., Scrutton, N. S., Baines, R. A., & Jones, A. R. (2014). Cryptochrome-dependent magnetic field effect on seizure response in Drosophila larvae. Scientific Reports. https://doi.org/10.1038/srep05799
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.