Fully printed flexible and disposable wireless cyclic voltammetry tag
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A disposable cyclic voltammetry (CV) tag is printed on a plastic film by integrating wireless power transmitter, polarized triangle wave generator, electrochemical cell and signage through a scalable gravure printing method. By proximity of 13.56 MHz RF reader, the printed CV tag generates 320 mHz of triangular sweep wave from +500 mV to −500 mV which enable to scan a printed electrochemical cell in the CV tag. By simply dropping any specimen solution on the electrochemical cell in the CV tag, the presence of solutes in the solution can be detected and shown on the signage of the CV tag in five sec. 10 mM of N,N,N′,N′-tetramethyl-p-phenylenediamine (TMPD) was used as a standard solute to prove the working concept of fully printed disposable wireless CV tag. Within five seconds, we can wirelessly diagnose the presence of TMPD in the solution using the CV tag in the proximity of the 13.56 MHz RF reader. This fully printed and wirelessly operated flexible CV tag is the first of its kind and marks the path for the utilization of inexpensive and disposable wireless electrochemical sensor systems for initial diagnose hazardous chemicals and biological molecules to improve public hygiene and health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For these reasons, R2R gravure has previously been developed to print flexible electronic devices including thin film transistors, wireless cyclic voltammetry tags, and a carbon nanotubebased active matrix for tactile sensors, but has been underutilized in the context of recent advancements in wearable electrochemical biosensors.[17][18][19][20]”
From Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices (2018) · cites this paper as [17]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ascaso, J. F., Pardo, S., Real, J. T., Lorente, R. I., Priego, A., & Carmena, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.12.3320 · Cited by 490
Research works printed but not linked: 20
- Sanderson, M. D., Kamplain, J. K. & Bielawski, C. W. Quinone-annulated N-heterocyclic carbene-transition-metal complexes: Observation of π-back bonding using FT-IR spectroscopy and cyclic voltammetry. J. Am. Chem. Soc 128, 16514–16515 (2006). · DOI · Paper page
- Lai, R. Y., Fabrizio, E. F., Lu, L., Jenekhe, S. A. & Bard, A. J. Synthesis, cyclic voltammetrics studies and electrogenerated chemiluminescence of a new donor-acceptor molecule: 3,7-[Bis[4-phenyl-2-quinolyl]]-10-methylphenothiazine. J. Am. Chem. Soc 123, 9112–9118 (2001). · doi:10.1021/ja0102235
- Armstrong, F. A., Hill, H. A. & Walton, N. J. Direct electrochemistry of redox proteins. Acc. Chem. Res 21, 407–413 (1998). · doi:10.1021/ar00155a004
- Norouzi, P., Ganjali, M. R., Daneshgar, P., Alizadeh, T. & Mohammadi, A. Development of fast Fourier transformation continuous cyclic voltammetry as a highly sensitive detection system for ultra-trace monitoring of penicillin V. Anal. Biochem 360. 175–184 (2007). · doi:10.1016/j.ab.2006.09.027
- Koyama, J. et al. Correlation of redox potentials and inhibitory effects on Epstein-Barr virus activation of 2-azaanthraquinones. Cancer Letters 212, 1–6 (2004). · doi:10.1016/j.canlet.2004.03.005
- Teijeiro, C., Perez, P., Marin, D. & Paleček, E. Cyclic voltammetry of mitomycin C and DNA. Bioelectrochemistry and Bioenergetics 38, 77–83 (1995). · doi:10.1016/0302-4598(95)01791-c
- Zerihun, T. & Gründler, P. Electrically heated cylindrical microelectrodes. Determination of lead on Pt by cyclic voltammetry and cathodic stripping analysis. J. Electroanal Chem 415, 85–88 (1996). · doi:10.1016/s0022-0728(96)04711-0
- Bond, A. M. & Scholz, F. Electrochemical, Thermodynamic and mechanistic data derived from voltammetric studies on insoluble metallocenes, mercury halide and sulfide compounds, mixed silver halide crystals and other metal complexes following their mechanical transfer to a graphite electrode. Langmuir 7, 3197–3204 (1991). · doi:10.1021/la00060a046
- Brusciotti, F. & Duby, P. Cyclic voltammetry study of arsenic in acidic solutions. Electrochim Acta 52, 6644–6649 (2007). · doi:10.1016/j.electacta.2007.04.071
- Ruan, C., Yang, L. & Li, Y. Immunobiosensor chips for detection of escherichia coli O157:H7 using electrochemical impedance spectroscopy. Anal. Chem 74, 4814–4820 (2002). · doi:10.1021/ac025647b
- Liu, G. & Lin, Y. Electrochmical sensor for orgnohposphate pesticides and nerve agents using zirconia nanoparticles as selective sorbents. Anal. Chem 77, 5894–5901 (2005). · DOI · Paper page
- Karl, T. et al. Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling. J. Appl. Physiol 91, 762–770 (2001). · DOI · Paper page
- Armstrong, F. A. Recent developments in dynamic electrochemical studies of adsorbed enzymes and their active sites. Chem. Biol 9, 110–117 (2005).
- Mollah, M. Y., Schennach, R., Parga, J. R. & Cocke, D. L. Electrocoagulation (EC)-science and applications. J. Hazard. Mater B84, 29–41 (2001). · DOI · Paper page
- Park, H. et al. Fully roll-to-roll gravure printed rectenna on plastic foils for wireless power transmission at 13.56 MHz. Nanotech 23, 344006–344012 (2012). · DOI · Paper page
- Kang, H. et al. Fully Roll-to-Roll Gravure Printable Wireless (13.56 MHz) Sensor-Signage Tags for Smart Packaging. Sci. Rep. 4, 5387; 10.1038/srep05387 (2014). · DOI
- Jung, M. et al. All-printed and roll-to-roll-printable 13.56 MHz-operated 1-bit RF tag on plastic foils. IEEE Trans Electron Devices 57, 3, 571–580 (2010). · DOI · Paper page
- Noh, J. et al. Integrable single walled carbon nanotube (SWNT) network based thin film transistors using roll-to-roll gravure and inkjet. Org. Electron 12, 2185–5191 (2011). · DOI
- Noh, J. et al. Modeling of printed single walled carbon nanotube thin film transistors for attaining optimized clock signals. J. Appl. Phys 108, 10, 102811–102817 (2010). · doi:10.1063/1.3511698
- Noh, J. et al. Fully Gravure-Printed Flexible Full Adder Using SWNT-Based TFTs. IEEE. Eletron. Dev. Lett. 33, 11, 1574–1576 (2012). · DOI
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
A New Frontier of Printed Electronics: Flexible Hybrid Electronics
Khan, Y., Thielens, A., Muin, S., Ting, J., Baumbauer, C., & Arias, A. C. (2020) · Advanced Materials · doi:10.1002/adma.201905279 · Cited by 891
Wearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Printed Carbon Nanotube Electronics and Sensor Systems
Chen, K., Gao, W., Emaminejad, S., Kiriya, D., Ota, H., Nyein, H. Y. Y., Takei, K., & Javey, A. (2016) · Advanced Materials · doi:10.1002/adma.201504958 · Cited by 425
Self-citationRoll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices
Bariya, M., Shahpar, Z., Park, H., Sun, J., Jung, Y., Gao, W., Nyein, H. Y. Y., Liaw, T. S., Tai, L.-C., Ngo, Q. P., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b02505 · Cited by 417
Self-citation
Metadata
- Authors
- Jung, Y., Park, H., Park, J.-A., Noh, J., Choi, Y., Jung, M., Jung, K., Pyo, M., Chen, K., Javey, A., & Cho, G.
- Venue
- Scientific Reports
- Published
- 2015-01-29
- Volume
- 5
- Issue
- 1
- ISSN
- 2045-2322
- Cited by
- 66
- References
- 1
- Language
- en
- Licence
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.