Investigation of Tumor Cell Behaviors on a Vascular Microenvironment-Mimicking Microfluidic Chip
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The extravasation of tumor cells is a key event in tumor metastasis. However, the mechanism underlying tumor cell extravasation remains unknown, mainly hindered by obstacles from the lack of complexity of biological tissues in conventional cell culture and the costliness and ethical issues of in vivo experiments. Thus, a cheap, time and labor saving and most of all, vascular microenvironment-mimicking research model is desirable. Herein, we report a microfluidic chip-based tumor extravasation research model which is capable of simultaneously simulating both mechanical and biochemical microenvironments of human vascular systems and analyzing their synergistic effects on the tumor extravasation. Under different mechanical conditions of the vascular system, the tumor cells (HeLa cells) had the highest viability and adhesion activity in the microenvironment of the capillary. The integrity of endothelial cells (ECs) monolayer was destroyed by tumor necrosis factor-α (TNF-α) in a hemodynamic background, which facilitated the tumor cell adhesion, this situation was recovered by the administration of platinum nanoparticles (Pt-NPs). This model bridges the gap between cell culture and animal experiments and is a promising platform for studying tumor behaviors in the vascular system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crossing the endothelial barrier during metastasis
Reymond, N., d'Água, B. B., & Ridley, A. J. (2013) · Nature Reviews Cancer · doi:10.1038/nrc3628 · Cited by 922
Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1210182109 · Cited by 872
Plaks, V., Koopman, C. D., & Werb, Z. (2013) · Science · doi:10.1126/science.1235226 · Cited by 722
Interstitial flow influences direction of tumor cell migration through competing mechanisms
Polacheck, W. J., Charest, J. L., & Kamm, R. D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1103581108 · Cited by 509
Microfluidic Endothelium for Studying the Intravascular Adhesion of Metastatic Breast Cancer Cells
Song, J. W., Cavnar, S. P., Walker, A. C., Luker, K. E., Gupta, M., Tung, Y.-C., Luker, G. D., & Takayama, S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005756 · Cited by 317
In vitro model of tumor cell extravasation
Jeon, J. S., Zervantonakis, I. K., Chung, S., Kamm, R. D., & Charest, J. L. (2013) · PLoS ONE · doi:10.1371/journal.pone.0056910 · Cited by 233
Migration dynamics of breast cancer cells in a tunable 3D interstitial flow chamber
Haessler, U., Teo, J. C. M., Foretay, D., Renaud, P., & Swartz, M. A. (2012) · Integrative Biology · doi:10.1039/c1ib00128k · Cited by 176
A microfluidic-based device for study of transendothelial invasion of tumor aggregates in realtime
Zhang, Q., Liu, T., & Qin, J. (2012) · Lab on a Chip · doi:10.1039/c2lc00030j · Cited by 151
Cited by
Shirure, V. S., Bi, Y., Curtis, M. B., Lezia, A., Goedegebuure, M. M., Goedegebuure, S. P., Aft, R., Fields, R. C., & George, S. C. (2018) · Lab on a Chip · doi:10.1039/c8lc00596f · Cited by 316
Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Tang, Y., Soroush, F., Sheffield, J. B., Wang, B., Prabhakarpandian, B., & Kiani, M. F. (2017) · Scientific Reports · doi:10.1038/s41598-017-09815-9 · Cited by 102
Bridging the gap between tumor-on-chip and clinics: a systematic review of 15 years of studies
Bouquerel, C., Dubrova, A., Hofer, I., Phan, D. T. T., Bernheim, M., Ladaigue, S., Cavaniol, C., Maddalo, D., Cabel, L., Mechta-Grigoriou, F., et al. (2023) · Lab on a Chip · doi:10.1039/d3lc00531c · Cited by 58
Metadata
- Authors
- Huang, R., Zheng, W., Liu, W., Zhang, W., Long, Y., & Jiang, X.
- Venue
- Scientific Reports
- Published
- 2015-12-03
- Volume
- 5
- Issue
- 1
- Pages
- 17768-17768
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2410018865
- Cited by
- 38
- References
- 8
- FWCI
- 2.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.