CoChat

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

A microfluidic-based device for study of transendothelial invasion of tumor aggregates in realtime

Zhang, Qian, Liu, Tingjiao, Qin, Jianhua · 2012 · Lab on a Chip

Abstract

Circulating tumor aggregates exhibit a high metastatic potential and could potentially serve as an important target for cancer therapies. In this study, we developed a microfluidic model that reconstitutes and is representative of the principal components of biological blood vessels, including vessel cavity, endothelium, and perivascular matrix containing chemokines. Using this model, the transendothelial invasion of tumor aggregates can be observed and recorded in realtime. In this study we analyzed the extravasation process of salivary gland adenoid cystic carcinoma (ACC) cell aggregates. ACC aggregates transmigrated across the endothelium under the stimulation of chemokine CXCL12. The endothelial integrity was irreversibly damaged at the site of transendothelial invasion. The transendothelial invasion of ACC aggregates was inhibited by AMD3100, but the adhesion of ACC aggregates to the endothelium was not affected by the CXCR4 antagonist. This model allows for detailed study of the attachment and transendothelial invasion of tumor aggregates; thus, it would be a useful tool for analysis of the underlying mechanisms of metastasis and for testing novel anti-metastasis agents.

Overview

Integrity signals

Registry

Crossref · 10.1039/c2lc00030j

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 43 references

Research works printed but not linked: 6

  1. Graves, 2011, Patholog. Res. Int., 2011, 621090
  2. Komatsubara, 2005, Kobe J Med Sci, 51, 67
  3. Paget, 1989, Cancer Metastasis Rev, 8, 98
  4. Chen, 2005, Methods Mol Biol, 294, 15
  5. Woodward, 2002, Invest Ophthalmol Vis Sci, 43, 1708
  6. Glinsky, 2003, Cancer Res, 63, 3805

Cited by

See all 161

Metadata

Authors
Zhang, Q., Liu, T., & Qin, J.
Affiliations
  • Dalian Medical University (CN)
  • Dalian Institute of Chemical Physics (CN)
Corresponding author
  • Liu, Tingjiao
  • Qin, Jianhua
Venue
Lab on a Chip
Published
2012
Volume
12
Issue
16
Pages
2837
ISSN
  • 1473-0189 (ISSN-L)
  • 1473-0197
OpenAlex
W2137116096
Cited by
151
References
43
Citations by year
2026: 3 · 2024: 3 · 2023: 8 · 2022: 8 · 2021: 8 · 2020: 16 · 2019: 17 · 2018: 11 · 2017: 21 · 2016: 14 · 2015: 15 · 2014: 11 · 2013: 14 · 2012: 2
FWCI
6.64
Type
journal article
Language
en
Open access
closed
Locations
  • Lab on a Chip (publishedVersion)
  • PubMed (publishedVersion)
  • Dalian Institute of Chemical Physics, CAS Institutional Repository (submittedVersion)
Topics
  • Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
metastasis, salivary adenoid cystic carcinoma, CXCL12, CXCR4, AMD3100, endothelial integrity, cell extravasation, chemokines
MeSH terms
Cyclams, Benzylamines, Cell Adhesion, Cell Movement, Endothelium, Vascular, Heterocyclic Compounds, Humans, Models, Biological, Receptors, CXCR4, Cell Line, Tumor, Microfluidic Analytical Techniques, Chemokine CXCL12, Human Umbilical Vein Endothelial Cells

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A microfluidic-based device for study of transendothelial invasion of tumor aggregates in realtime. https://app.cochat.ai/papers/10.1039/c2lc00030j
The paper
Zhang, Q., Liu, T., & Qin, J. (2012). A microfluidic-based device for study of transendothelial invasion of tumor aggregates in realtime. Lab on a Chip. https://doi.org/10.1039/c2lc00030j

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.