The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Synthesis, characterization and application of reversible PDLLA-PEG-PDLLA copolymer thermogels in vitro and in vivo
Open accessAbstract
In this study, a series of injectable thermoreversible and thermogelling PDLLA-PEG-PDLLA copolymers were developed and a systematic evaluation of the thermogelling system both in vitro and in vivo was performed. The aqueous PDLLA-PEG-PDLLA solutions above a critical gel concentration could transform into hydrogel spontaneously within 2 minutes around the body temperature in vitro or in vivo. Modulating the molecular weight, block length and polymer concentration could adjust the sol-gel transition behavior and the mechanical properties of the hydrogels. The gelation was thermally reversible due to the physical interaction of copolymer micelles and no crystallization formed during the gelation. Little cytotoxicity and hemolysis of this polymer was found and the inflammatory response after injecting the hydrogel to small-animal was acceptable. In vitro and in vivo degradation experiments illustrated that the physical hydrogel could retain its integrity as long as several weeks and eventually be degraded by hydrolysis. A rat model of sidewall defect-bowel abrasion was employed and a significant reduction of post-operative adhesion has been found in the group of PDLLA-PEG-PDLLA hydrogel-treated, compared with untreated control group and commercial hyaluronic acid (HA) anti-adhesion hydrogel group. As such, this PDLLA-PEG-PDLLA hydrogel might be a promising candidate of injectable biomaterial for medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermosensitive polymeric hydrogels as drug delivery systems
Gong, C., Qi, T., Wei, X., Qu, Y., Wu, Q., Luo, F., & Qian, Z. (2012) · Current Medicinal Chemistry · doi:10.2174/0929867311302010009 · Cited by 228
Self-citation
Cited by
Soft Materials by Design: Unconventional Polymer Networks Give Extreme Properties
Zhao, X., Chen, X., Yuk, H., Lin, S., Liu, X., & Parada, G. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01088 · Cited by 1,161
Yuan, Y., Shen, S., & Fan, D. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120838 · Cited by 407
Shao, J., Ruan, C., Xie, H., Li, Z., Wang, H., Chu, P. K., & Yu, X. (2018) · Advanced Science · doi:10.1002/advs.201700848 · Cited by 367
PEG-based thermosensitive and biodegradable hydrogels
Shi, J., Yu, L., & Ding, J. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.04.009 · Cited by 341
Polymer scaffolds as drug delivery systems
Calori, I. R., Braga, G., de Jesus, P. D. C. C., Bi, H., & Tedesco, A. C. (2020) · European Polymer Journal · doi:10.1016/j.eurpolymj.2020.109621 · Cited by 288
Poly(lactic acid) based hydrogels
Basu, A., Kunduru, K. R., Doppalapudi, S., Domb, A. J., & Khan, W. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.07.004 · Cited by 188
Drug delivery based on stimuli-responsive injectable hydrogels for breast cancer therapy: A review
Xin, H., & Naficy, S. (2022) · Gels · doi:10.3390/gels8010045 · Cited by 83
Mayes, S. M., Davis, J., Scott, J., Aguilar, V., Zawko, S. A., Swinnea, S., Peterson, D. L., Hardy, J. G., & Schmidt, C. E. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2020.02.027 · Cited by 64
He, X. Y., Sun, A., Li, T., Qian, Y. J., Qian, H., Ling, Y. F., Zhang, L. H., Liu, Q. Y., Peng, T., & Qian, Z. (2020) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2020.116692 · Cited by 64
Self-citationShi, H., Zhu, Y., Xing, C., Li, S., Bao, Z., Lei, L., Lin, D., Wang, Y., Chen, H., & Xu, X. (2022) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2022.122081 · Cited by 29
Self-citation
Metadata
- Authors
- Shi, K., Wang, Y.-L., Qu, Y., Liao, J.-F., Chu, B.-Y., Zhang, H.-P., Luo, F., & Qian, Z.-Y.
- Venue
- Scientific Reports
- Published
- 2016-01-11
- Volume
- 6
- Issue
- 1
- Pages
- 19077-19077
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2239185014
- Cited by
- 175
- References
- 1
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.