The DOI matches its Crossref record.
A Disposable paper breathalyzer with an alcohol sensing organic electrochemical transistor
Open accessAbstract
Breathalyzers estimate Blood Alcohol Content (BAC) from the concentration of ethanol in the breath. Breathalyzers are easy to use but are limited either by their high price and by environmental concerns, or by a short lifetime and the need for continuous recalibration. Here, we demonstrate a proof-of-concept disposable breathalyzer using an organic electrochemical transistor (OECT) modified with alcohol dehydrogenase (ADH) as the sensor. The OECT is made with the conducting polymer poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) and is printed on paper. ADH and its cofactor nicotinamide adenine dinucleotide (NAD+) are immobilized onto the OECT with an electrolyte gel. When the OECT-breathalyzer is exposed to ethanol vapor, the enzymatic reaction of ADH and ethanol transforms NAD+ into NADH, which causes a decrease in the OECT source drain current. In this fashion, the OECT-breathalyzer easily detects ethanol in the breath equivalent to BAC from 0.01% to 0.2%. The use of a printed OECT may contribute to the development of breathalyzers that are disposable, ecofriendly and integrated with wearable devices for real-time BAC monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Organic electrochemical transistors
Rivnay, J., Inal, S., Salleo, A., Owens, R. M., Berggren, M., & Malliaras, G. G. (2018) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.86 · Cited by 2,065
Self-citationDevice physics of organic electrochemical transistors
Friedlein, J. T., McLeod, R. R., & Rivnay, J. (2018) · Organic Electronics · doi:10.1016/j.orgel.2018.09.010 · Cited by 429
Electrolyte-gated transistors for enhanced performance bioelectronics
Torricelli, F., Adrahtas, D. Z., Bao, Z., Berggren, M., Biscarini, F., Bonfiglio, A., Bortolotti, C. A., Frisbie, C. D., Macchia, E., Malliaras, G. G., et al. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00065-8 · Cited by 422
Self-citationFunctionalized Organic Thin Film Transistors for Biosensing
Wang, N., Yang, A., Fu, Y., Li, Y., & Yan, F. (2019) · Accounts of Chemical Research · doi:10.1021/acs.accounts.8b00448 · Cited by 361
Complementary Logic Circuits Based on High‐Performance n‐Type Organic Electrochemical Transistors
Sun, H., Vagin, M., Wang, S., Crispin, X., Forchheimer, R., Berggren, M., & Fabiano, S. (2018) · Advanced Materials · doi:10.1002/adma.201704916 · Cited by 353
Metadata
- Authors
- Bihar, E., Deng, Y., Miyake, T., Saadaoui, M., Malliaras, G. G., & Rolandi, M.
- Venue
- Scientific Reports
- Published
- 2016-06-13
- Volume
- 6
- Issue
- 1
- Pages
- 27582-27582
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2436780494
- Cited by
- 167
- References
- 0
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Disposable paper breathalyzer with an alcohol sensing organic electrochemical transistor. https://app.cochat.ai/papers/10.1038/srep27582
- The paper
- Bihar, E., Deng, Y., Miyake, T., Saadaoui, M., Malliaras, G. G., & Rolandi, M. (2016). A Disposable paper breathalyzer with an alcohol sensing organic electrochemical transistor. Scientific Reports. https://doi.org/10.1038/srep27582
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.