Focused Ultrasound-Induced Blood-Brain Barrier Opening: Association with Mechanical Index and Cavitation Index Analyzed by Dynamic Contrast-Enhanced Magnetic-Resonance Imaging
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Focused ultrasound (FUS) with microbubbles can temporally open the blood-brain barrier (BBB), and the cavitation activities of microbubbles play a key role in the BBB-opening process. Previous attempts used contrast-enhanced magnetic resonance imaging (CE-MRI) to correlate the mechanical index (MI) with the scale of BBB-opening, but MI only partially gauged acoustic activities, and CE-MRI did not fully explore correlations of pharmacodynamic/pharmacokinetic behaviors. Recently, the cavitation index (CI) has been derived to serve as an indicator of microbubble-ultrasound stable cavitation, and may also serve as a valid indicator to gauge the level of FUS-induced BBB opening. This study investigates the feasibility of gauging FUS-induced BBB opened level via the two indexes, MI and CI, through dynamic contrast-enhanced (DCE)-MRI analysis as well as passive cavitation detection (PCD) analysis. Pharmacodynamic/pharmacokinetic parameters derived from DCE-MRI were characterized to identify the scale of FUS-induced BBB opening. Our results demonstrated that DCE-MRI can successfully access pharmacodynamic/pharmacokinetic BBB-opened behavior, and was highly correlated both with MI and CI, implying the feasibility in using these two indices to gauge the scale of FUS-induced BBB opening. The proposed finding may facilitate the design toward using focused ultrasound as a safe and reliable noninvasive CNS drug delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure and function of the blood–brain barrier
Abbott, N. J., Patabendige, A. A. K., Dolman, D. E. M., Yusof, S. R., & Begley, D. J. (2010) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.07.030 · Cited by 5,185
The blood-brain barrier: Bottleneck in brain drug development
Pardridge, W. M. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.3 · Cited by 2,798
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679
Fan, C.-H., Liu, H.-L., Ting, C.-Y., Lee, Y.-H., Huang, C.-Y., Ma, Y.-J., Wei, K.-C., Yen, T.-C., & Yeh, C.-K. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096327 · Cited by 84
Self-citationLiu, H., Hsu, P., Chu, P., Wai, Y., Chen, J., Shen, C., Yen, T., & Wang, J. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21599 · Cited by 54
Self-citation
Cited by
Crossing the blood-brain barrier with nanoparticles
Zhou, Y., Peng, Z., Seven, E. S., & Leblanc, R. M. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.12.015 · Cited by 837
“However, the temporary disruption of tight junctions inducing the opening of the BBB with osmotic pressure [30], microbubbles [31] and ultrasound [32] are risky.”
BackgroundMechanical and Biological Effects of Ultrasound: A Review of Present Knowledge
Izadifar, Z., Babyn, P., & Chapman, D. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.01.023 · Cited by 280
Sonabend, A. M., Gould, A., Amidei, C., Ward, R., Schmidt, K. A., Zhang, D. Y., Gomez, C., Bebawy, J. F., Liu, B. P., Bouchoux, G., et al. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(23)00112-2 · Cited by 260
Magnetic iron oxide nanoparticles for brain imaging and drug delivery
Qiao, R., Fu, C., Forgham, H., Javed, I., Huang, X., Zhu, J., Whittaker, A. K., & Davis, T. P. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114822 · Cited by 245
Arvanitis, C. D., Askoxylakis, V., Guo, Y., Datta, M., Kloepper, J., Ferraro, G. B., Bernabeu, M. O., Fukumura, D., McDannold, N., & Jain, R. K. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1807105115 · Cited by 236
“1), including studies in different disease models and animals (60).”
BackgroundState-of-the-art of microbubble-assisted blood-brain barrier disruption
Song, K.-H., Harvey, B. K., & Borden, M. A. (2018) · Theranostics · doi:10.7150/thno.26869 · Cited by 184
Chen, K.-T., Wei, K.-C., & Liu, H.-L. (2019) · Frontiers in Pharmacology · doi:10.3389/fphar.2019.00086 · Cited by 164
“FUS-BBB opening could enhance delivery of immune-stimulating agents such as interleukin-12 (IL-12) (Chen et al., 2015a) or immune check point inhibitors such as anti-cytotoxic T-lymphocyteassociated antigen 4 (CTLA-4) monoclonal antibodies (mAb) to affect the tumor immunosuppressive…”
Self-citationWang, J., Li, Z., Pan, M., Fiaz, M., Hao, Y., Yan, Y., Sun, L., & Yan, F. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114539 · Cited by 161
Focused ultrasound/microbubbles-assisted BBB opening enhances LNP-mediated mRNA delivery to brain
Ogawa, K., Kato, N., Yoshida, M., Hiu, T., Matsuo, T., Mizukami, S., Omata, D., Suzuki, R., Maruyama, K., Mukai, H., et al. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.05.042 · Cited by 161
Aducanumab delivery via focused ultrasound-induced transient blood–brain barrier opening in vivo
Jeong, J., Han, M., Jeon, S., Kim, Y., Choi, H. J., Choi, W., Kwon, K., Choi, J.-R., & Lee, E.-H. (2025) · Scientific Reports · doi:10.1038/s41598-025-02412-1 · Cited by 13
“To evaluate the dynamics of contrast agents in the brain, we performed DCE-MRI 31–33 .”
Influential
Metadata
- Authors
- Chu, P.-C., Chai, W.-Y., Tsai, C.-H., Kang, S.-T., Yeh, C.-K., & Liu, H.-L.
- Venue
- Scientific Reports
- Published
- 2016-09-15
- Volume
- 6
- Issue
- 1
- Pages
- 33264-33264
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2519325617
- Cited by
- 136
- References
- 5
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.