How a High-Gradient Magnetic Field Could Affect Cell Life
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
The biological effects of high-gradient magnetic fields (HGMFs) have steadily gained the increased attention of researchers from different disciplines, such as cell biology, cell therapy, targeted stem cell delivery and nanomedicine. We present a theoretical framework towards a fundamental understanding of the effects of HGMFs on intracellular processes, highlighting new directions for the study of living cell machinery: changing the probability of ion-channel on/off switching events by membrane magneto-mechanical stress, suppression of cell growth by magnetic pressure, magnetically induced cell division and cell reprograming, and forced migration of membrane receptor proteins. By deriving a generalized form for the Nernst equation, we find that a relatively small magnetic field (approximately 1 T) with a large gradient (up to 1 GT/m) can significantly change the membrane potential of the cell and thus have a significant impact on not only the properties and biological functionality of cells but also cell fate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control of Stem Cell Fate by Physical Interactions with the Extracellular Matrix
Guilak, F., Cohen, D. M., Estes, B. T., Gimble, J. M., Liedtke, W., & Chen, C. S. (2009) · Cell Stem Cell · doi:10.1016/j.stem.2009.06.016 · Cited by 1,850
Schenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
The Magnetic Properties and Structure of Hemoglobin, Oxyhemoglobin and Carbonmonoxyhemoglobin
Pauling, L., & Coryell, C. D. (1936) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.22.4.210 · Cited by 1,159
(1998) · doi:10.1007/978-3-540-85054-0 · Cited by 1,145
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Hydrostatic pressure and the actomyosin cortex drive mitotic cell rounding
Stewart, M. P., Helenius, J., Toyoda, Y., Ramanathan, S. P., Muller, D. J., & Hyman, A. A. (2011) · Nature · doi:10.1038/nature09642 · Cited by 693
Biofunctionalized magnetic-vortex microdiscs for targeted cancer-cell destruction
Kim, D.-H., Rozhkova, E. A., Ulasov, I. V., Bader, S. D., Rajh, T., Lesniak, M. S., & Novosad, V. (2010) · Nature Materials · doi:10.1038/nmat2591 · Cited by 611
Membrane potential is important for bacterial cell division
Strahl, H., & Hamoen, L. W. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1005485107 · Cited by 553
Remote control of cellular behaviour with magnetic nanoparticles
Dobson, J. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.39 · Cited by 528 · cited 1×
“ + G RT n n zFV ln , (3) i”
TRP channels in mechanosensation: direct or indirect activation?
Christensen, A. P., & Corey, D. P. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2149 · Cited by 513
Cited by
Three-dimensional in vitro culture models in oncology research
Jubelin, C., Muñoz-Garcia, J., Griscom, L., Cochonneau, D., Ollivier, E., Heymann, M.-F., Vallette, F. M., Oliver, L., & Heymann, D. (2022) · Cell & Bioscience · doi:10.1186/s13578-022-00887-3 · Cited by 264
Sleep Medicine - Asleep or Awake?
(2024) · doi:10.5772/intechopen.104201 · Cited by 5
Metadata
- Authors
- Zablotskii, V., Polyakova, T., Lunov, O., & Dejneka, A.
- Venue
- Scientific Reports
- Published
- 2016-11-18
- Volume
- 6
- Issue
- 1
- Pages
- 37407-37407
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W2552214854
- Cited by
- 221
- References
- 59
- FWCI
- 8.72
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.