CoChat

Fluorimetric method for the determination of low concentrations of dissolved aluminium in natural waters

Hydes, D. J., Liss, P. S. · 1976 · The Analyst
Cited by 230

The DOI matches its Crossref record.

Abstract

Dissolved aluminium occurs in natural waters down to concentrations of 1 µg l–1 or less. There are very few methods that are sufficiently sensitive to measure down to these levels. A fluorimetric method using the reagent Lumogallion has been investigated and found to have a detection limit of 0.05 µg l–1 of aluminium and a coefficient of variation of 5% at the 1.0 µg l–1 level and 2.7% at the 22 µg l–1 level. The only anionic interference likely to be important in most natural waters is that from fluoride, and this interference can be dealt with by using an incremental calibration procedure. For acidic waters iron is a potential interferent but has no significant effect at concentrations of less than 100 µg l–1. In water abnormally rich in dissolved organic material there may be competition for the dissolved aluminium between the natural organic ligands and the Lumogallion. This effect can be overcome by ultraviolet irradiation prior to analysis for aluminium. The analysis detects all forms of aluminium in filtered natural water samples except when the aluminium occurs in stable mineral structures, e.g., clay particles small enough to pass through the filter. Aluminium adsorbed on the surface of such particulate material appears to be determined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1039/an9760100922

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hydes, D. J., & Liss, P. S.
Venue
The Analyst
Published
1976
Volume
101
Issue
1209
Pages
922
ISSN
  • 0003-2654 (ISSN-L)
  • 1364-5528
OpenAlex
W1978406567
Cited by
230
References
0
FWCI
5.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.