The DOI matches its Crossref record.
Particle size distributions and compositions of aerosols produced by near-IR femto- and nanosecond laser ablation of brass
Abstract
Particle size distributions and compositions of primary aerosols produced by means of near-IR femtosecond laser ablation (λ = 775 nm) of brass in He or Ar at atmospheric pressure have been measured. Aerosols were characterized using a 13-stage low-pressure impactor covering a size range from 5 nm up to 5 μm and subsequently analyzed applying total reflection X-ray fluorescence spectrometry. The results indicate, that for femtosecond laser ablation in the low-fluence regime (<5 J cm−2) ultra-fine aerosols (mean diameter dp ≈ 10 nm/peak width wp ≈ 35 nm) are produced. Furthermore, the total Cu/Zn ratio of these aerosols corresponds to the composition of the bulk material. In contrast, ablation above 10 J cm−2 results in the formation of polydisperse, bimodal aerosols, which are distributed around dp1 ≈ 20 nm (wp1 ≈ 50 nm) and dp2 ≈ 1 μm (wp2 ≈ 5 µm), respectively, and whose total Cu/Zn ratio slightly deviates from the bulk composition. In order to examine the influence of pulse duration on particle size distribution and aerosol composition, comparative measurements by means of near-IR nanosecond ablation were also performed. The data show that nanosecond ablation generally leads to an intensified formation of particles in the micrometer range. Moreover, the composition of these aerosols strongly departs from the stoichiometry of the bulk. Aspects concerning the formation of particles during ablation as well as implications for the element-selective analysis by inductively coupled plasma spectrometry are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Calibration-Free Laser-Induced Breakdown Spectroscopy: State of the art
Tognoni, E., Cristoforetti, G., Legnaioli, S., & Palleschi, V. (2010) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2009.11.006 · Cited by 465
Gaudiuso, R., Dell’Aglio, M., Pascale, O. D., Senesi, G. S., & Giacomo, A. D. (2010) · Sensors · doi:10.3390/s100807434 · Cited by 306
Review of the State-of-the-Art of Laser Ablation Inductively Coupled Plasma Mass Spectrometry
Koch, J., & Günther, D. (2011) · Applied Spectroscopy · doi:10.1366/11-06255 · Cited by 270
Self-citationGeneration of nanoparticle colloids by picosecond and femtosecond laser ablations in liquid flow
Barcikowski, S., Menéndez-Manjón, A., Chichkov, B., Brikas, M., & Račiukaitis, G. (2007) · Applied Physics Letters · doi:10.1063/1.2773937 · Cited by 225
Bärsch, N., Jakobi, J., Weiler, S., & Barcikowski, S. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/44/445603 · Cited by 122
Jakobi, J., Menéndez-Manjón, A., Chakravadhanula, V. S. K., Kienle, L., Wagener, P., & Barcikowski, S. (2011) · Nanotechnology · doi:10.1088/0957-4484/22/14/145601 · Cited by 78
Marzun, G., Levish, A., Mackert, V., Kallio, T., Barcikowski, S., & Wagener, P. (2017) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2016.09.014 · Cited by 68
Metadata
- Authors
- Koch, J., von Bohlen, A., Hergenröder, R., & Niemax, K.
- Venue
- J. Anal. At. Spectrom.
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2004
- Volume
- 19
- Issue
- 2
- Pages
- 267-272
- ISSN
- 0267-9477 (ISSN-L)
- 1364-5544
- OpenAlex
- W2061740773
- Cited by
- 232
- References
- 0
- FWCI
- 13.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.